ADI LT boiler – Technical manual
Page
52
18. BOILER GUARANTEE
1. ARTICULOS DOMESTICO-INDUSTRIALES CALEFACCION, S.L. (ADISA CALEFACCION) guarantees
the ADI LT boilers of its own manufacturing as follows:
* 3 years for the boiler heat exchanger
* 2 years for the rest of components
2. The GUARANTEE takes effect from the invoicing date of the material by ADISA CALEFACCIÓN.
3. The COMMISSIONING is not included in the price of the boiler. It must be realized by the Official Technical
Assistance Services of ADISA CALEFACCIÓN that will also check if the installation complies with the
minimum requirements for the boiler correct operation. They will provide the responsible of the installation
with a sealed copy of the GUARANTEE CERTIFICATE.
4. Repairing or replacing components or parts of the boiler does not extend the period of the guarantee,
neither for the pieces that are replaced.
5. The elements in guarantee will be repaired or replaced freely in case of manufacturing faults.
6. The Official Technical Assistance Services are the only competent services that can carry out repairs under
guarantee and ADISA will send its technical staff according to its own internal organization planning. In
case other people external to ADISA manipulate the boiler, the guarantee would lose its effect.
7. The parts replaced under guarantee will remain property of ADISA CALEFACCIÓN, and the user is obliged
to return them to ADISA CALEFACCIÓN free of charges within a maximum period of 7 days, otherwise the
spare parts provided will be invoiced.
8. The guarantee just covers the material repairing. The guarantee does not cover the expenses for the
dismantling of the equipments, for the installation and/or for the local or premises where they are installed,
neither for the connections of the new equipments, or for additional works necessary to repair the material.
9. In order to consider as “GUARANTEE” the spare parts or the replaced components of the boilers, the
installation should comply with the requirements described in this manual.
Guarantee will not be valid when breakdowns are due to:
A. No correct installation, no proper use, inadequate manipulation or maintenance of the boiler.
B. Electric supply different from: 220/230 V, 50Hz, single phase, earth connection.
C. No correct sizing or execution of the chimney and of the flues outlets. Bad evacuation of the
condensed products generated by the smokes in the chimney.
D. Force majeure such as: fire, flood, sinking, freezing of the circuit water...
E. No proper water quality requirements both for the water of the circuit and the water supplied.
Values must be:
-
Total hardness (TH): lower than 12ºF
-
PH: between 9,6 and 10
-
Iron content: lower than 1 mg/litre
-
Resistivity: higher than 2000 Ohms*cm (conductivity lower than 500 microS/cm)
-
Turbidity: lower than 10 mg/litre
-
Salinity: lower than 50 mg/litre
-
Chloride: lower than 100 mg/litre
F. Lack of water. It is obligatory to supply the installation with minimum water content, so that it can
circulate through the boiler with constant flow and without interruption.
G. Gas connection: no correct pressure, no proper dimensions or inadequate type of gas.
Содержание ADI LT 105
Страница 1: ...5 2010 ADI LT BOILER LOW TEMPERATURE TECHNICAL MANUAL OF INSTALLATION USE AND MAINTENANCE ...
Страница 7: ...ADI LT boiler Technical manual Page 7 Models ADI LT 250 and higher A C D B J Q H G F E R S N L M P ...
Страница 28: ...ADI LT boiler Technical manual Page 28 ELECTRIC DRAWING ADI LT 250 325 ...
Страница 29: ...ADI LT boiler Technical manual Page 29 ELECTRIC DRAWING ADI LT 400 750 ...
Страница 57: ......