background image

AD Instruments _____________________________________________________________________

 

©Copyright Abacanto Digital SA.                          Manual de usuario AD2Q01F             20 

General Specifications

 

 

 

Operation Temperature

 

 

-10 C~+50 C

 

 

Storage Temperature

 

 

-20 C~+70 C

 

 

Humidity

 

 

<90%

 

 

Size(HXWXD)

 

 

160mmx76mmx45mm

 

 

Weight

 

 

0.27 kg(including batteries)

 

Содержание AD2Q01F

Страница 1: ...Instrument Manual ADInstruments Quad wavelength laser source AD2Q01F ...

Страница 2: ...urning Product 2 4 Contact us Safety Information Preparing for Operation 4 1 Unpacking the instrument 4 2 Power Supply Operation 5 1 Display and controls 5 2 Turning the instrument on and off 5 3 Switching the wavelengths 5 4 Frequency Output 5 5 Auto wavelength Recognition 5 6 Switching backlighting of the LCD on and off 5 7 Connecting with Optical Power Meter Specifications Maintenance Trouble s...

Страница 3: ...e optical fiber testing Two output connector serves four wavelengths 850nmII300nmII3I0nmII550nm AD2Q0IF can be used to test optical fiber of long distance and local network Also it can work with optical power meter to measure the loss of optical fiber S M Features Easy to use straight forward operation Eye catching handheld package LCD backlight for easy operation in darker environments Rechargeab...

Страница 4: ...e defective within the warranty period would be returned to Abacanto Digital authorized service center for repair replacement and calibration Exclusions The warranty on your equipment shall not apply to defects resulting from the following Unauthorized repair or modification including battery replacement Misuse negligence or accident Returning Product To return product you may contact Abacanto Dig...

Страница 5: ...________________________________________________________ Copyright Abacanto Digital SA Manual de usuario AD2Q01F 5 Contact Us Tel Fax E mail Website 34 91 661 30 37 34 91 661 49 17 info abacantodigital com www abacantodigital com ...

Страница 6: ...cal current may cause personal injury due to fumes electric shock or equipment damage Connect DC power cord with the equipment and wall socket properly While inserting the DC plug make sure there is no dust or dirt on the terminals and both plugs are fully seated Incomplete engagement may cause fuming electric shock or equipment damage and may result in personal injury Do not operate the equipment...

Страница 7: ...trument during transit Checking the package contents The standard accessories of AD2QOIF are as follows Main unit including battery Quality Check Report DC 6V Adapter Carrying Case User s Guide Checking for damage in transit After unpacking the instrument check to see whether it was damaged in transit This is particularly likely if the outer casing is clearly damaged If there is damage do not atte...

Страница 8: ...ry indicator on the screen When you do not connect the DC 6v charger the adapter indicator will disappear on the screen When you use the battery the battery indicator on the screen will show the remaining charge An empty battery indicator means the power is almost out When the battery charge is extremely low to supply the necessary power the instrument will automatically switch off after several b...

Страница 9: ...strument without Auto off function and continuous wavelength 850nm l300nm l3l0nm and l550nm TWIN Auto wavelength recognition is on No Key Function l 2s PERM ON OFF Switches Instrument on off Long keypress while powering on to 2 S M Switch between Single Mode and Multimode 3 CW Hz Modulated Wavelength Shifting Key Switches modulated wavelength 4 Wavelength Shifting Key Switches working wavelength b...

Страница 10: ...top Connector 2 Connector I FC PC SC PC ST PC Battary Plate including 2 units of AA recharging batteries DC 6v power input Charging Signal light Red light blinking means charging Green light means charging finish Standard Accessories FC PC SC PC ST PC interchangeable connector Manual Carrying Bag and Battery Worldwide compatible AC DC adapter Test Report ...

Страница 11: ...________________________ Copyright Abacanto Digital SA Manual de usuario AD2Q01F 11 5 1 3 LCD Wavelength DC Adapter Battery Charge l888 nm Modulation Power Measurement Unit dBm Auto wavelength Recognition Auto off 8 8 8 8 270H z 1kH z 2kH z SINGLE TWIN AUTO OFF ...

Страница 12: ... off 13 10 nm 5 0 AUTO OFF Press the ON OFF key briefly The instrument powers on See the figure Press the ON OFF key briefly again The instrument powers off SINGLE Note Auto off function I The instrument powers off automatically if no key press in I0 minutes 2 Press the ON OFF key for about 2 seconds to power on the instrument with Auto off function deactivated 2s PERM ON OFF ...

Страница 13: ...__ Copyright Abacanto Digital SA Manual de usuario AD2Q01F 13 5 3 Switching the wavelengths 5 3 1 Switching the wavelengths in the in the Singlemode Press the then Press to Mulitimode Key to switch the S M wavelength between l3lOnm l55Onm and 0ff 0ff 1550 1310 nm 5 0 SINGLE AUTO OFF ...

Страница 14: ...___________________ Copyright Abacanto Digital SA Manual de usuario AD2Q01F 14 5 3 2 Switching the wavelengths in the in the Multimode Press the then Press to Mulitimode Key to switch the S M wavelength between 850nm l300nm and 0ff 0ff 1300 850 nm 5 0 SINGLE AUTO OFF ...

Страница 15: ...l SA Manual de usuario AD2Q01F 15 5 4 Frequency Output 5 0 270Hz 1kHz The instrument defaults to CW when it switch on When it is set to CW there is no frequency on display Press the CW Hz Key to select the output among 270Hz 1kHz and 2kHz 1 CW is not displayed on the LCD CW Hz 13 10 nm 1 2kHz CW SINGLE AUTO OFF ...

Страница 16: ...________________________________________________________ Copyright Abacanto Digital SA Manual de usuario AD2Q01F 16 5 5 Auto wavelength Recognition Press the TWIN Key to tun on and off the auto wavelength recognition function TWIN ...

Страница 17: ...yright Abacanto Digital SA Manual de usuario AD2Q01F 17 Copyright Abacanto Digital SA de usuario AD2Q01F 17 5 6 Switching backlighting of the LCD on and off Press the backlighting Key to switch the backlighting of the LCD on and off 13 10 nm 13 10 nm 5 0 5 0 SINGLE SINGLE AUTO OFF AUTO OFF ...

Страница 18: ..._________________________________________________ Copyright Abacanto Digital SA Manual de usuario AD2Q01F 18 5 7 Connecting with Optical Power Meter It can work with optical power meter to measure the loss of optical fiber accurately SIM ...

Страница 19: ...ions Model FHS2QOIF Output wavelength nm 850 1300 1310 1550 Laser Class Ι Spectral Width 3nm typical value Stability 15 min preheat 25 0 05dB 15min 0 1dB 5hr CW output power 5 0dBm 1dB Modulated Wavelength 270Hz 1kHz 2kHz Available Connector FC PC SC PC ST PC Interchangeable connectors Power 2 units of AA recharging battaries AC Adapter 2Input AC 100 240V 50 60HZ Output DC 6V 1A ...

Страница 20: ...__________________________________ Copyright Abacanto Digital SA Manual de usuario AD2Q01F 20 General Specifications Operation Temperature 10 C 50 C Storage Temperature 20 C 70 C Humidity 90 Size HXWXD 160mmx76mmx45mm Weight 0 27 kg including batteries ...

Страница 21: ...harger and cover the protective dust cap once you finish using It is a good idea to clean the connector and the instrument when they get dirty through use Optical cleaning pads and anhydrous alcohol is recommended And please be careful not to get the detergent inside the instrument To ensure the measurement accuracy please send the instrument to our Service Center for calibration once a year ...

Страница 22: ... factory On off disorder Low battery Charge battery or use AC power supply DIY Available Inaccurate measurement Contaminated connector Swab the dust by using an alcohol impregnated thin cotton swab DIY Available Connector unfitted Re install the connector DIY Available Error display Humid environment Try later while it is not too humid DIY Available Magnetic field environment Stay far away from ma...

Отзывы: