DTU2xx Data Logger Series
User Guide. r. 2.1 | 2021-11-10
Tel.: +420 538 890 720
25
e-mail: [email protected]
Information on connected device
In order to read the information on the connected data
logger in the table, click the Read Current Settings button
on the control panel. In case any parameters are not
displayed, wait for a while and click the button once again.
The following information is displayed in the table:
Model name
– DTU data logger model name.
Device time
– current date and time established in
data logger at the first connection to the server.
When you first configure, and if the synchronization
with the server was not performed, the device could
display the date and time parameters that differ
from the current ones.
DST shift
– parameter displays daylight saving time
shift (if enabled). If the DST option is enabled (on
the
Schedule
tab), data logger reads the shift value
depending on the set DST mode. If the DST option
is disabled, no information is displayed in the line.
GSM operation time
— time period of the device
power supply operation starting from the device
switch-on and to the current moment. The
parameter is non-resettable.
GSM connection
— GSM module status
(Enabled/Disabled).
Modem IMEI
— Data Logger GSM module
identification number.
SIM card parameters:
SIM status (active/not active), serial number (CCID), international mobile
subscriber identity (IMSI), DTU cellular network registration.
Operator code (PLMN)
Signal level, %
— signal emission power level in the GSM network.
GPRS connection
— parameter becomes active, when the GPRS connection is established.
TCP connection
— parameter becomes active, when the TCP connection is established (the
indicator starts flashing red).
Transparent channel
— parameter becomes active only when the transparent channel on
the
Interfaces
tab is enabled in the Separate mode. Possible states: Not active, Authorization,
Active. Parameter for DTU2xx only.
U power supply, V
– accumulator battery voltage (in Volts).
Battery capacity discharge, mAh
— the current amount of consumed battery power (in mAh)
Firmware
— the current version of firmware installed in the data logger.
Fig. 22. Information about the connected
device.