SET COMMUNICATION:
This section define the fundamental communication parameters of two buses, EtherCAT and
CANopen.
By Pressing the “
Set Communication
” button from the main window for SW67E08 (Fig. 2)
the window “Set Communication” appears (Fig. 3).
The means of the fields for “EtherCAT Slave” are:
In the field “
Revision Number
” the revision number of the converter is defined;
In the field “
Slave Name
” the name of the converter is defined;
In the field
“Node Address
” the ID of the converter is defined.
The means of the fields for the “CANopen” section are:
In the field “
Device ID
” the ID of the CANopen side is defined;
In the field “
Baud Rate
” the data rate of the CANopen line is defined;
In the field “
Set Operational State at Start-Up
” the state of the CANopen is
defined. I.e. If it is checked the board starts in Operational State, else it starts in Pre-
Operational;
In the field “
Network Start at Start-Up
” the state of the CANopen network is
defined. I.e. If it is checked the board sends a command to set the Operational State
of all the devices present in the network, after the time defined in the “Delay” field;
In the field “
Delay (seconds)
” the delay before sending the “Start” command for the
CANopen is defined;
In the field “
SDO Client TimeOut (1/10 ms)
” the maximum time that the device
attends for the answer from the Slave interrogated is defined;
Figure 3: “Set Communication” window