Figure 4b: “Set MQTT Topics 

 MQTT Subscribe” window 

 

MQTT

 

S

UBSCRIBE

 

 

 
 
 
 
 
 
 
 
 
 
 
 

 
 

The means of the fields are: 

 

In the field “

Topic

” the MQTT topic is defined; 

 

In the field “

QoS

” the QoS level is defined; 

 

In the field “

Mnemonic

” a description of the topic is defined.

 

Содержание HD67941-B2

Страница 1: ...HD67935 Modbus TCP Master www adfweb com Product HD67936 Modbus TCP Slave www adfweb com Product HD67937 BACnet Master www adfweb com Product HD67938 BACnet Slave www adfweb com Product HD67939 CAN ww...

Страница 2: ...ISCLAIMER 39 OTHER REGULATIONS AND STANDARDS 39 WARRANTIES AND TECHNICAL SUPPORT 40 RETURN POLICY 40 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need...

Страница 3: ...an be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation of thi...

Страница 4: ...Industrial Electronic Devices ADFweb com S r l User Manual DALI MQTT Document code MN67941_ENG Revision 1 000 Page 4 of 40 EXAMPLE OF CONNECTION...

Страница 5: ...Industrial Electronic Devices ADFweb com S r l User Manual DALI MQTT Document code MN67941_ENG Revision 1 000 Page 5 of 40 CONNECTION SCHEME Figure 1 Connection scheme for HD67941 B2...

Страница 6: ...n between Ethernet and DALI Mountable on 35mm Rail DIN Wide power supply input range 18 35V DC and 8 24V AC Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATION You need Compositor SW67941 softwa...

Страница 7: ...NG Revision 1 000 Page 7 of 40 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumption at 24V...

Страница 8: ...osition of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is used for upl...

Страница 9: ...te in progress 2 DALI communication yellow Blinks when DALI communication is running Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 MQTT status yellow ON MQTT not connected OF...

Страница 10: ...ght switch to lighting management systems for entire office complexes with thousands of light sources Using ADFweb com s DALI converters any light source including incandescent lamps fluorescent lamps...

Страница 11: ...cation The Ethernet connection must be made using Connector2 of HD67941 B2 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568...

Страница 12: ...ter use the available software that runs with Windows called SW67941 It is downloadable on the site www adfweb com and its operation is described in this document The software works with MS Windows XP...

Страница 13: ...iguration A device s configuration can also be imported or exported To clone the configurations of a Programmable DALI MQTT Converter in order to configure another device in the same manner it is nece...

Страница 14: ...guage of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possible to check...

Страница 15: ...ual DALI MQTT Document code MN67941_ENG Revision 1 000 Page 15 of 40 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation inside the tabl...

Страница 16: ...By Pressing the Set Communication button from the main window for SW67941 Fig 2 the window Set Communication appears Fig 3 The window is divided in different sections in order to define the different...

Страница 17: ...ined If the field Clean Session is checked the last MQTT messages are deleted by the Server and the Client in case of missing ACK If unchecked the Server and the Client hold the last MQTT messages and...

Страница 18: ...ed ETHERNET This section is used to define the general parameters of Ethernet The means of the fields are In the field Ip Address the IP address of the converter is defined In the field SubNet Mask th...

Страница 19: ...DNS the DNS address is defined This field is required if the server address is define by URL and not IP Address In the field Port the port used for MQTT communication is defined In the field SSID the...

Страница 20: ...converter is defined In the field Subnet Mask the SubNet Mask of the converter is defined In the field GATEWAY the default gateway of the net is defined This feature can be enabled or disabled pressi...

Страница 21: ...abled in the field Server Certificate the certificate from the Server is defined If the field Client Authentication is checked the authentication of the Client using TLS is enabled If enabled o in the...

Страница 22: ...erter will subscribes for writing the data to DALI MQTT PUBLISH The means of the fields are In the field Topic the MQTT topic is defined If the field Retained is defined the retained flag is enabled T...

Страница 23: ...e MN67941_ENG Revision 1 000 Page 23 of 40 Figure 4b Set MQTT Topics MQTT Subscribe window MQTT SUBSCRIBE The means of the fields are In the field Topic the MQTT topic is defined In the field QoS the...

Страница 24: ...41 Fig 2 the window Select the DALI Device Present in the Network appears Fig 4 This section is used to define the DALI devices connected to the converter It is enough to check uncheck the connected u...

Страница 25: ...ble Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip1 of Dip S...

Страница 26: ...tart the PC Check the LAN settings If you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have th...

Страница 27: ...e to use the available software that runs with Windows called DALI Console It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to th...

Страница 28: ...work and program automatically the IDs Search menu export import the results of the communication Dali File menu and see the informations about the DALI Console software About menu Network view Fig 9...

Страница 29: ...tware the SETUP window appears Fig 9 The means of the fields for the SETUP window are In the field DEVICE IP ADDRESS the IP address set inside the converter is defined In the field PRG PORT the commun...

Страница 30: ...ype of DALI device is printed In the field Software version the software version of the DALI device is printed In the fields Power Range Min value Actual value Max value System Fail value Power On val...

Страница 31: ...s which the selected DALI device is in The checked checkboxes mean that the device is in the correspondent groups the unchecked checkboxes mean that the device is not included in the correspondent gro...

Страница 32: ...le to insert the value to set in the field xx As soon as the command to send is selected the command is sent in order to send the same command more times it is possible to press the SEND COMMAND butto...

Страница 33: ...de MN67941_ENG Revision 1 000 Page 33 of 40 SCENES By selecting a DALI scene from the Network view it is possible to see the devices that have programmed the selected scene It is also possible to acti...

Страница 34: ...lue to set in the field xx As soon as the command to send is selected the command is sent in order to send the same command more times it is possible to press the SEND COMMAND button In the field COMM...

Страница 35: ...is possible to have a simple text format or a JSON format The definition of the template can be done using Key words used to link a specific information from DALI The key words used and their meaning...

Страница 36: ...and compose the Modbus request It is necessary to use a JSON format described below channel CHANNEL value VALUE Where CHANNEL ID of the DALI node VALUE value of the ADV hex format The DALI ID can have...

Страница 37: ...Industrial Electronic Devices ADFweb com S r l User Manual DALI MQTT Document code MN67941_ENG Revision 1 000 Page 37 of 40 Figure 15 Mechanical dimensions scheme for HD67941 B2 MECHANICAL DIMENSIONS...

Страница 38: ...a valid combination of the following HD67941 B 2 Connectors Type 2 Fixed Screw Terminal Enclosure Type B Modulbox 2M 35mm DIN Rail mounting Device Family HD67941 DALI MQTT Converter Order Code HD67941...

Страница 39: ...tems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recycling o...

Страница 40: ...following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to the ad...

Отзывы: