Industrial
Electronic Devices
ADFweb.com S.r.l.
User Manual
Modbus TCP Slave / Modbus Master
Document code: MN67507_ENG Revision 2.400 Page 30 of 45
Figure 3f: “Set Communication
Wi-Fi” window
W
I
-F
I
:
This section is used to define the general parameters of Wi-Fi. It is possible to defined the type of Wi-Fi communication:
Access Point;
Client.
The means of the fields for Access Point configuration are:
In the field “
IP Address
” the IP address of the converter is defined;
In the field “
Subnet Mask
” the SubNet Mask of the converter is defined;
In the field “
GATEWAY
” the default gateway of the net is defined. This
feature can be enabled or disabled pressing the Check Box field. This feature
is used for going out of the net;
In the field “
SSID
” the name of the Wi-Fi network to create is defined;
In the field “
Password
” the password used for Wi-Fi connection is defined;
In the field “
Type
” the type of security protocol used by the Wi-Fi network is
defined;
If the field “
Enable DHCP
” is checked, the converter acts as DHCP Server
for the Clients connected. If the option is enabled, in the fields “
DHCP First
IP Address
” and “
DHCP SUBNET Mask
” the IP Addresses range used for
DHCP is defined. In the field “
Lease Time (seconds)
” the required time for
the renewing of the IP Address assigned to the Client is defined;
In the field “
Max Client
” the maximum number of Wi-Fi Clients accepted is defined;
In the field “
Channel
” the channel for Wi-Fi communication is defined.