Control Panel Layout and Buttons Configurations:

 

RANGE HOOD OPERATIONS

While the range hood is off and Auto Function is activated, the blower will turn on to its highest

 speed     

        

automatically when the internal temperature is 4 times above the external temperature.

 Then it will         

        

adjust the speed level (between speed levels F4 to F1) automatically according to the

 detected tempera-    

        

ture between the sensors (4 times to 1 time). The speed level can also be

 manually overwritten by   

        

press the

Increase

or

Decrease

button and Auto Function will reactivate

 after 2 minutes. The blower can   

        

ONLY be turned off MANUALLY or activate the delay off timer

 finction.

While the range hood is off, press and hold

Auto Function

button to enter the temperature setting

 

mode.

        

Press

Increase

or

Decrease

button to adjust the comparison temperature value between

 the internal   

        

and external heat sensors from 8°F to 20°F. The temperature setting mode will exit

 automatically after 

       

5 seconds of inactivity.

Press

Auto Function

button to Turn On/Off the Auto Mode. The Auto Function Icon will appear in

 the

        

LCD Panel when Auto Mode is On.

In addition to the remote-control feature, this range hood is also equipped with a heat sensor that will selfcali-

brate in 5 seconds when the range hood is first electrically activated and beeps when selfcalibration is

 

done.

To conserve energy, the LCD panel will turn off automatically after 5 seconds of inactivity.

Adjusting Heat Sensitive Auto Speed (HSAS) Function:

Activating Normal Blower Function:

While the range hood is off, press

Increase

or

Decrease

button to start the blower. Press

Increase

 button

to increase blower speed (F1 to F4) as indicated in LCD panel. The

Increase

button cycles

 blower settings

from off (00), quiet speed (F1), low speed (F2), medium speed (F3) to high speed

 (F4).

While the range hood is on and the blower is running, press

Decrease

button to decrease blower

 

speed

        

(F4 to F1) as indicated in LCD panel. The

Decrease

button cycle blower settings from highspeed (F4),

        

to medium speed (F3), low speed (F2), quiet speed (F1) to off (00).

Activating Light Function:

Press Light button once to turn on the lights, and once again to turn off the lights.

CAUTION: DO NOT touch the lights until switched OFF and cooled.

Activating Power-Off Delay Function:

While the range hood is on and the blower is running, press Power-Off

 Delay button to activate delay    

        

off timer and “Power-Off Delay” icon will appear in LCD panel

 .Adjust to desired period of delay off timer   

        

by pressing Increase or Decrease button (minimum 1 minute to maximum 15minutes.

 Timer begins to

        

countdown immediately, when it reaches 0, the blower will shut off.

Adjusting Clock Function:

14

While the range hood is off, press Power-off Delay button once to enter the clock setting mode,

 press 

Increase or Decrease button to set the Hour. Press the Power-off Delay button again to set

 the Min.

Press the Power-off Delay button again to exit the clock setting mode.

Содержание AP238-PS83-36

Страница 1: ...Installer Leave this manual with the homeowner Homeowner Keep this guide for future reference 2021A IMPORTANT Read and save these instructions MODEL AP238 PS83 36 AP238 PS83 48 INSTALLATION GUIDE USE...

Страница 2: ......

Страница 3: ...ide them to the electrical inspector in your area INSTALLER Please leave these instructions with the owner of the unit OWNER Keep these instructions for future reference SECURITY WARNING Turn off the...

Страница 4: ...or cleaning the unit switch power off at the service panel and lock the service disconnecting means stop revent power from being switched on accidentally If the service disconnecting means cannot be l...

Страница 5: ...fire with your back to anexit Smother flames with a close fitting lid cookie sheet or metal tray and then turn off the burner If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTM...

Страница 6: ...stablewrench Sheet metalsheers Needle nose pliers Scissors to cut duct tape Duct tape Marker or pencil Level Measuring tape PARTS INCLUDED Filters INSTALLATION INSTRUCTIONS TOOLS NEEDED TO INSTALL THE...

Страница 7: ...ng surface and bottom of the hood 28 30 D Hood height 9 8 E Cabinet height N A Installation The information contained herein is based on sources that we believe to be reliable but is not guaranteed by...

Страница 8: ...irflow exhaust use a straight run or as few elbows aspossible Vent unit to the exterior only At least two people are required for installation Remove the range hood from the carton packaging and place...

Страница 9: ...operation It is recommended that the range hood be vented vertically through the roof through 8 20 3 cm round metal aluminum vent or vented horizontally through the wall through a rectangular vent me...

Страница 10: ...to maximize airflow when connecting to duct provided VENTING METHODS INSTALLATIONDIAGRAMS Vent work can terminate either through the roof or wall To vent through a wall a 90 elbow may be needed This r...

Страница 11: ...ic shock by providing an escape wire for the electric current Position the outlet offset so that the power cord will not interfere with the round duct Make sure this does not interfere with the mounti...

Страница 12: ...ugh the back of the hood For a Step 1 Determine the venting method and proceed if you would like tovent VERTICALLY see INSTALLATION DIAGRAMS on page 7 more secure installation use as many mounting hol...

Страница 13: ...rovided through the back of the hood Step 8 Drop oil tunnel into recess support near rear of hood See figure 6 Figure 6 Figure 7 To install baffle filters and stainless spacer s refer to figure 7 and...

Страница 14: ...panel will turn off automatically after 5 seconds of inactivity Adjusting Heat Sensitive Auto Speed HSAS Function Activating Normal Blower Function While the range hood is off press Increase or Decrea...

Страница 15: ...ssure 0 2 One sone is roughly equivalent to the sound of a refrigerator 1kHz at 40 decibels 3 Subject to change without notice please contact your local reseller for details CIRCUIT DIAGRAM Body Desig...

Страница 16: ...embly Motor Fan Blade Protective Grill and Squirrel Cage Electrical Assembly Baffle Filter Power Cord Ducting Transition No 1 2 3 4 5 6 7 8 9 1 No Description Description Description No 4 1 4 2 4 3 4...

Страница 17: ...EEL FOR EXTENDED PERIODS MANY OF THESE COMPOUNDS CONTAIN CHEMICALS WHICH MAY BE HARMFUL RINSE WITH WATER AND WIPE DRY WITH A CLEAN CLOTH CLEANING THE GREASE FILTER The filters are intended to filter o...

Страница 18: ...N breaker and range hood to testfor operation This range hood uses LED light fixture 3W Max 12V LED 18 REPLACING THE LED LIGHT BULBS CAUTION LED lamps canonly be replacedwith a new LED lamp The lamp r...

Страница 19: ...er maintenance use of corrosive and abrasive cleaning products pads and oven cleaner products Chips dents or cracks due to abuse misuse freight damage or improper installation Damage of product caused...

Страница 20: ......

Отзывы: