background image

19

SERVICE AND WARRANTY

LIMITED WARRANTY

One Year Part s Warrant y:

For one year from t he dat e of original purchase, your local reseller w ill provide free of charge, non-consumable 
replacement  part s or component s t hat  failed due t o manufact uring defect s. Subject  t o t he condit ions and limit at ions 
set  fort h below , your local reseller w ill, at  it s opt ion, eit her repair or replace any part  of it s product s t hat  prove 
defect ive by reason of improper w orkmanship or mat erials. Repaired part s or replacement  product s w ill be provided 
by your local reseller on an exchange basis, and w ill be eit her new  or refurbished t o be funct ionally equivalent  t o new . 
The consumer is responsible for all shipping cost s. Consumable part s not  covered by t his w arrant y include but  not  
limit ed t o: Light  bulbs, met al and cont rol panel.

Who is Covered:

This w arrant y is ext ended t o t he original purchaser for product s purchased for ordinary home use.

This Warrant y Will Be Voided When:
Product  damaged t hrough negligence, improper inst allat ion, accident , abuse, misuse, nat ural disast er, insufficient  or 
excessive elect rical supply, abnormal mechanical or environment al condit ions, or any unaut horized disassembly, 
repair, modificat ion, or failure t o follow  inst allat ion inst ruct ions. When product  is used commercially or ot her t han it s 
int ended purpose. Damaged because of improper connect ion w it h equipment  of ot her manufact urers. Repaired or 
modified by anyone ot her t han your local reseller’ s aut horized agent s. This limit ed w arrant y also does not  apply t o any 
product  on w hich t he original ident ificat ion informat ion has been alt ered, oblit erat ed or removed, has not  been handled 
or packaged correct ly or has been sold as second-hand.

What  is Not  Covered:

Consumable part s such as light  bulbs, met al and cont rol panel. The nat ural w ear of finish, and w ear due t o improper 
maint enance, use of corrosive and abrasive cleaning product s, pads, and oven cleaner product s. Chips, dent s or cracks 
due t o abuse, misuse, freight  damage, or improper inst allat ion. Damage of product  caused by accident , fire, floods or 
act  of God. The manufact urer and/ or dist ribut or/ reseller is not  liable for, and does not  cover under w arrant y, any loss 
ofpropert ies or any cost s associat ed w it h removing, servicing, inst alling, or det ermining t he source of problems w it h 
t his product .

This w arrant y is valid in t he count ry of t he original purchase at  ret ail. It  is non-t ransferable and applies only t o t he 
original purchaser and does not  ext end t o subsequent  ow ners of t his product . Any applicable implied w arrant ies, 
including t he w arrant y of merchant abilit y, are limit ed in durat ion t o a period of express w arrant y as provided herein 
beginning w it h t he dat e of original purchase at  ret ail and, no w arrant ies, w het her express or implied, shall apply t o t his 
product  t hereaft er.

To obt ain w arrant y service, you may cont act  your local reseller from w hich you purchased t his product . Please confirm 
t he t erms of your local reseller’ s policies prior t o cont act ing. Typically, you must  include product  ident ificat ion infor-
mat ion, including model number and serial number w it h a det ailed descript ion of t he problem you are experiencing. 
You must  also include proof of t he dat e of original ret ail purchase as evidence t hat  t he product  is w it hin t he applicable 
w arrant y period.

Cont act  Us

If you need any assist ance, please cont act  your local reseller. Please have your order number and model of t he 
range hood ready. This informat ion w ill help t hem bet t er respond t o your request .

If you need replacement  part s, w e recommend t hat  you only use genuine part s. Our accessories and part s are 
engineered and designed specifically for t his series of range hood, each is rigorously t est ed assuring t he ut most  
in durabilit y and reliabilit y, providing a fact ory mat ch, fact ory-inst alled appearance and funct ionalit y t ailored t o 
each individual range hood model.

Содержание AP238- PS83- 36

Страница 1: ...D Installer Leave this manual with the homeowner Homeowner Keep this guide for future reference 2021A IMPORTANT Read and save these instructions MODEL AP238 PS83 36 AP238 PS83 48 INSTALLATION GUIDE USE AND CARE MANUAL ...

Страница 2: ......

Страница 3: ...ide them to the electrical inspector in your area INSTALLER Please leave these instructions with the owner of the unit OWNER Keep these instructions for future reference SECURITY WARNING Turn off the power circuit in the electrical panel and lock the front panel before connecting the wires of this unit Requirements 2 2 0V 5 0Hz 3 IMPORTANT SAFETY PRECAUTIONS 4 5 INSTALLATION INSTRUCTIONS 6 13 OPER...

Страница 4: ...g or cleaning the unit switch power off at the service panel and lock the service disconnecting means stop revent power from being switched on accidentally If the service disconnecting means cannot be locked securely fasten a noticeable warning device such a tag to the service panel Usethis unit only inthe manner intended by the manufacturer Ifyou haveany questions contact the Follow the heating e...

Страница 5: ... fire with your back to anexit Smother flames with a close fitting lid cookie sheet or metal tray and then turn off the burner If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT Never pick up a flaming pan you may BURN YOURSELF DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result Use an extinguisher ONLY if WARNING The manufacturer an...

Страница 6: ...ustablewrench Sheet metalsheers Needle nose pliers Scissors to cut duct tape Duct tape Marker or pencil Level Measuring tape PARTS INCLUDED Filters INSTALLATION INSTRUCTIONS TOOLS NEEDED TO INSTALL THE RANGE HOOD 6 Qty 8 pcs for drywall only Qty 8 pcs Qty 1 0 pcs Ducting Transition Grease tunnel ...

Страница 7: ...ing surface and bottom of the hood 28 30 D Hood height 9 8 E Cabinet height N A Installation The information contained herein is based on sources that we believe to be reliable but is not guaranteed by us may be incomplete and or may change without notice 7 DIMENSIONS FOR 36 4 8 HOOD Overall Rear Knockout Holes ...

Страница 8: ...airflow exhaust use a straight run or as few elbows aspossible Vent unit to the exterior only At least two people are required for installation Remove the range hood from the carton packaging and place on a flat surfacefor assembly CAUTION THIS APPLIANCE SHOULD BE PROPERLYGROUNDED The range hood must be connected with copper wire plug only Make sure the unit is connected to an individual properly ...

Страница 9: ...t operation It is recommended that the range hood be vented vertically through the roof through 8 20 3 cm round metal aluminum vent or vented horizontally through the wall through a rectangular vent measuring 3 x10 The size of the vent should be uniform If venting vertically do not use more than three 90 elbows Do not install two elbows together Make sure there is a minimum of 24 61 cm of straight...

Страница 10: ... to maximize airflow when connecting to duct provided VENTING METHODS INSTALLATIONDIAGRAMS Vent work can terminate either through the roof or wall To vent through a wall a 90 elbow may be needed This range hood is factory set for vertical venting using round or rectangular vent adapter but can be converted to horizontal venting by swapping the round vent adapter on top with rectangular vent adapte...

Страница 11: ...ric shock by providing an escape wire for the electric current Position the outlet offset so that the power cord will not interfere with the round duct Make sure this does not interfere with the mountingbracket ADVANCED PREPARATION Decide on the location of the venting pipe from the hood tothe outside A straight shortventrun willallowthe hoodtoperformmore efficiently Tryto avoidasmany transitions ...

Страница 12: ...ugh the back of the hood For a Step 1 Determine the venting method and proceed if you would like tovent VERTICALLY see INSTALLATION DIAGRAMS on page 7 more secure installation use as many mounting holes as needed to secure from the inside of hood Use 7 round steel pipe follow building codes in your area to connect the exhaust on the hood to Step 3 Step 5 Store excess wires in the wiring box Step 2...

Страница 13: ...provided through the back of the hood Step 8 Drop oil tunnel into recess support near rear of hood See figure 6 Figure 6 Figure 7 To install baffle filters and stainless spacer s refer to figure 7 and follow these five steps For a moresecure installation use as many mounting holes as needed to secure from the inside of hood Use an 8 round metal pipe follow building codes in your area to connect th...

Страница 14: ...panel will turn off automatically after 5 seconds of inactivity Adjusting Heat Sensitive Auto Speed HSAS Function Activating Normal Blower Function While the range hood is off press Increase or Decrease button to start the blower Press Increase button to increase blower speed F1 to F4 as indicated in LCD panel The Increase button cycles blower settings from off 00 quiet speed F1 low speed F2 mediu...

Страница 15: ...essure 0 2 One sone is roughly equivalent to the sound of a refrigerator 1kHz at 40 decibels 3 Subject to change without notice please contact your local reseller for details CIRCUIT DIAGRAM Body Design Power Rating General Input Power M otor Input Power Ampere Levels Of Speed Control Airflow M ax 15 Single M otor Dual Chamber Ultra Quiet 220 240V 50Hz 3A 4 Leves 1000CFM 1 4Sone 45dB 3 5Sone 58dB ...

Страница 16: ...sembly M otor Fan Blade Protective Grill and Squirrel Cage Electrical Assembly Baffle Filter Power Cord Ducting Transition No 1 2 3 4 5 6 7 8 9 1 No Description Description Description No 4 1 4 2 4 3 4 4 4 5 4 6 4 7 4 8 Screw Air Flow Grill Left Locknut Left Squirrel Cage M otor Right Squirrel Cage Right Locknut Air Chamber ...

Страница 17: ...TEEL FOR EXTENDED PERIODS MANY OF THESE COMPOUNDS CONTAIN CHEMICALS WHICH MAY BE HARMFUL RINSE WITH WATER AND WIPE DRY WITH A CLEAN CLOTH CLEANING THE GREASE FILTER The filters are intended to filter out residue and grease from cooking and are required to be kept clean Filters should be cleaned after every 30 hours of use or once a month depending on use Remove and clean by hand in soapy water or ...

Страница 18: ...ON breaker and range hood to testfor operation This range hood uses LED light fixture 3W Max 12V LED 18 REPLACING THE LED LIGHT BULBS CAUTION LED lamps canonly be replacedwith a new LED lamp The lamp rating must be equal to the one already used Make sure all the control switches are off and the hood is unplugged or the breaker isOFF Replacing the LED light fixture Apply force to the metal clip and...

Страница 19: ...per maintenance use of corrosive and abrasive cleaning products pads and oven cleaner products Chips dents or cracks due to abuse misuse freight damage or improper installation Damage of product caused by accident fire floods or act of God The manufacturer and or distributor reseller is not liable for and does not cover under warranty any loss ofproperties or any costs associated with removing ser...

Страница 20: ......