sigfox MODBUS MASTER - Guide utilisateur / User guide version V1.0.1
61
Page
of 80
FR
3.4.2 Network registers
The list of registers below allows you to change the behavior of the product application. This list is accessible in Provider mode following execu-
tion of the ATT63 Provider command.
These registers must be handled with caution because they could cause problems of communication or of non-compliance with the legislation in
force.
Register
Size
Description
Coding
Details
S202
4
Number of repetitions in
the case of a uplink frame
associated with a downlink
frame
Decimal
Default: 2
Min/max: 0 to 2
Unit: none
IMPORTANT: This number of repetitions only concerns the
uplink frames after which the product will open a listening
window for a downlink frame.
S317
1
Enabling the respect of the Duty
Cycle
Decimal
Default : 1 (enabled)
Min/max : 0 (disabled) à 1 (enabled)
Unit: none
WARNING :
Deactivation of the Duty Cycle may result in a violation of
the conditions of use of the frequency band, depending
on the use of the product, thus violating the regulations in
force.
In the case of disabling the Duty Cycle, the responsibility is
transferred to the user.
4. DESCRIPTION OF THE FRAMES
4.1. Uplink frame
The uplink frames of the product to the network have a different size depending of the transmitted data.
4.1.1 Fixed bytes
The first two bytes of the frame are systematically dedicated to indicate the frame code and the status as presented below:
0
1
2
3
4
5
6
7
8
9
10
Code
Statut
PAYLOAD
4.1.1.01
Byte code
This byte contains the code associated with the frame to facilitate its decoding by the data system.