EN
sigfox TEMP- Guide utilisateur / User guide version V2.0.1
69
Page
of 84
FR
• Byte 5:
o Bits 0 to 3:
0: deactivated
1: activated
o Bits 4 to 7: The user identifier defined in register 322
• Bytes 6 to 7: Value measured on the probe 1
• Signed value on 16 bits,
• Expressed in tenths of degrees,
• Most significant byte first
• The special value 0x8000, equivalent to -3276, 8°C is returned in the event of a fault in the sensor.
In the example in grey this gives:
• Byte 2=0xD1:
o Bits 0 to 3 = 0x1: The probe 1 is activated
o Bits 4 à 7 = 0xD: the identifier of the probe 1 defined by the user is equal to 0xD
• Bytes 3 to 4=0x015E: The value measured on the probe 1 is 350/10=35°C
• Byte 5=0x81:
o Bits 0 to 3 = 0x1: The probe 2 is activated
o Bits 4 to 7 = 0x8: the identifier of the probe 1 defined by the user is equal to 0x8
• Bytes 6 to 7=0xFF06: the hexadecimal value 0xFF06 = -250. Hence the value measured on the probe 2 is -250/10=-25°C
4.1.5 Reply frame to a register value request in a downlink frame
Following reception of a downlink frame with the code 0x40, the frame 0x31 is transmitted.
It contains all the values of the registers requested in the downlink frame 0x40.
0
1
2
3
4
5
6
...
11
Code
PAYLOAD
PAYLOAD
0x31
Status
VALUE1
VALUE1
VALUE2
VALUE3
VALUE3
...
X
In this example: CONFID1 is a 2-byte register, CONFID2 a 1-byte register and CONFID3 a 2-byte register.
If an error is detected in the request, the returned 0x31 frame will be empty.
4.1.6 Data Frame
This frame (0x43) contains the values measured on the different sensors.
0
1
2
3
4
5
6
7
8
9
10
Code
Status
PAYLOAD
0x43
Cf Status
probe 1
identifier
Value read on the
probe 1
Probe 2
identifier
Value read on the
probe 2
X
X
0x43
0xA2
0xD1
0x015E
0x82
0xFF06
Description of the frame:
• Byte 2:
o Bits 0 to 3:
0: deactivated
1: activated
o Bits 4 to 7: The user identifier defined in register 320
• Bytes 3 to 4: Value measured on the probe 1
• Signed value on 16 bits,
• Expressed in tenths of degrees,
• Most Significant Byte first
• The special value 0x8000, equivalent to -3276,8°C is returned in the event of a fault in the sensor.
Содержание ARF8181BA2D
Страница 5: ...FR sigfox TEMP Guide utilisateur User guide version V2 0 1 5 Page of 84 FR FRANCAIS...
Страница 7: ...FR sigfox TEMP Guide utilisateur User guide version V2 0 1 7 Page of 84 FR...
Страница 43: ...EN sigfox TEMP Guide utilisateur User guide version V2 0 1 43 Page of 84 FR ENGLISH...
Страница 45: ...EN sigfox TEMP Guide utilisateur User guide version V2 0 1 45 Page of 84 FR...
Страница 80: ...sigfox TEMP Guide utilisateur User guide version V2 0 1 80 Page of 84 DE FR DEUTSCH Vorschriften...