EN
sigfox TEMP- Guide utilisateur / User guide version V2.0.1
59
Page
of 84
FR
2.3. Operation of the LEDs
Mode
LED red state
LED green state
Transmission of frame (TEST mode only)
ON during the transmission cycle
Reception of frame (TEST mode only)
ON during the reception of a downlink frame
Product in Park mode
OFF
OFF
Magnet detection process (1 to 6 seconds)
OFF
ON from detection of the magnet up to a
maximum of 1 second
Product start (after detection of the magnet) OFF
Rapid flashing 6 cycles, 100 ms ON / 100
ms OFF
Switching to the Command mode
Continuously lit
Continuously lit
Battery level low
Flashing (0.5s ON every 60s)
Product faulty (return to factory)
Fixed ON
Product in production mode (TEST mode
only)
50ms ON / 30 s OFF
50ms ON / 30 s OFF (just before the red
LED)
Product in REPLI mode
Flashing (100ms ON / 100ms OFF) x 2 every 5s