SIGFOX PULSE - Mode d’emploi / User guide version V1.5
30
Page
of 41
1.4. Technical Specifications
1.4.1 General characteristics
Parameters
Value
Power supply voltage
3.6 V nominal
Power supply
Integrated Li-SOCl2 battery (radio management and querying of meters)
Operating temperature
-25°C / +70°C
Dimensions
105 x 50 x 27mm
Case
IP 67
SIGFOX Certification
SIGFOX Certification number : P_001F_D8E8_02
Radio standards
EN 300-220, EN 301-489
1.4.2 Product input tolerance characteristics
Parameters
Value
Min. pulse width
8ms
Max. pulse frequency
33Hz
Max current (open collector version)
1mA
Input resistance (dry contact version)
1kOhm
Max. voltage
3.6V
1.4.3 Battery life
Conditions of use
Transmission frequency
Number of meters
battery life
Product storage before use:
1 year maximum.
Calculations carried out at
a temperature of 20°C
140 frames per day
1
0.5 year
140 frames per day
2
0.5 year
100 frames per day
1
0.7 year
100 frames per day
2
0.7 year
50 frames per day
1
1.3 year
50 frames per day
2
1.3 year
20 frames per day
1
3 years
20 frames per day
2
3 years
2 frames per day
1
+10 years
2 frames per day
2
+10 years
1.4.4 Operating modes
SIGFOX PULSE has three states (modes) of operation.
• STANDBY
: this is the mode in which you receive your product (no transmission of radio frames).
• OPERATION
: this is the mode in which SIGFOX PULSE transmits frames periodically. To switch to this mode of operation, you need to
activate the product with a magnet (see §2.6 Product start-up).