Chapter 4: System Installation
Adept Viper s650/s850 Robot with MB-60R/eMB-60R User’s Guide, Rev F
Page 57 of 100
DANGER
: AC power installation must be performed by a skilled
and instructed person - refer to the
. Dur-
ing installation, unauthorized third parties must be prevented
from turning on power through the use of fail-safe lockout meas-
ures.
Facility Overvoltage Protection
The user must protect the robot from excessive overvoltages and voltage spikes. If the country
of installation requires a CE-certified installation, or compliance with
IEC
1131-2, the following
information may be helpful:
IEC
1131-2 requires that the installation must ensure that
Category II overvoltages (i.e., line spikes not directly due to lightning strikes) are not exceeded.
Transient overvoltages at the point of connection to the power source shall be controlled not to
exceed overvoltage Category II, i.e., not higher than the impulse voltage corresponding to the
rated voltage for the basic insulation. The user-supplied equipment or transient suppressor
shall be capable of absorbing the energy in the transient.
In the industrial environment, nonperiodic over-voltage peaks may appear on mains power
supply lines as a result of power interruptions to high-energy equipment (such as a blown fuse
on one branch in a 3-phase system). This will cause high-current pulses at relatively low volt-
age levels. The user shall take the necessary steps to prevent damage to the robot system (such
as by interposing a transformer). See
IEC
1131-4 for additional information.
AC Power Diagrams
E
E
N
N
L
L
F1 10A
MB-60R
1Ø 200–240 VAC
User-Supplied
AC Power Cable
Note: F1 is user-supplied, must be slow blow.
1Ø
200–240 VAC
20A
L = Line
N = Neutral
E = Earth Ground
Figure 4-3. Typical AC Power Installation with Single-Phase Supply
Содержание eMB-60R
Страница 1: ...Adept Viper s650 s850 Robot with MB 60R eMB 60R User s Guide...
Страница 2: ......
Страница 62: ......
Страница 70: ......
Страница 82: ......
Страница 92: ......
Страница 98: ......
Страница 99: ......
Страница 100: ...P N 05173 060 Rev F 5960 Inglewood Drive Pleasanton CA 94588 925 245 3400...