background image

AVR30 (E) QR33851

10

ENGLISH

EXTERNAL CONNECTIONS

ALARM IN
You can connect an alarm switch with a resistance
of 1 kohm or less or a door sensor.  Connect pin 

q

to pin 

!1

(ground) through the switches.

Note:  Do not apply a voltage to pin 

q

or  

!1

.

ALARM OUT
Approx. 12V is applied to pin 

w

during an alarm

recording.
Notes:
• When you have selected “PULSE” in the “ALARM

OUT” menu in the ALARM SET display, approx.
12V pulses will be applied to the output after the
alarm recording ends.

• When you have selected “DURATION” in the

“ALARM OUT” menu in the ALARM SET display,
no voltage is applied after the alarm recording
ends.

• The output impedance is approx. 100 ohm.

TAPE END OUT
Approx. 12V is applied to pin 

r

when the tape

reaches the end.
Notes:
• This does not operate when you have selected

“REWIND, RE-REC” in the “RECYCLE FUNC-
TIONS” menu in the ALARM SET display or you
have selected “REWIND, STOP IF ALARM” and
no alarm recording has been made.

• The output impedance is approx. 100 ohm.

TAPE END RST
The TAPE END OUT function can be turned off when
pin 

t

is shorted to pin 

!1

.

Note:  Do not apply a voltage to pin 

t

or 

!1

.

CAMERA SW OUT
Pin 

o

outputs the following signal each time a one-

field image is recorded.  You can combine this with
a video camera switcher which can be controlled
externally.
The output timing can be specified using the SELEC-
TION MENU screen.

REC START IN
Recording is started when 5-12V is applied to pin 

!0

.

ALARM REC RST
When pin 

e

is shorted to pin 

!1

during alarm

recording, alarm recording is stopped and the origi-
nal mode be restored.

ALARM IN

GND

q

!1

Pin Arrangement of 15-Pin Adapter

q

  ALARM IN

w

  ALARM OUT

e

  ALARM REC RST

r

  TAPE END OUT

t

  TAPE END RST

o

  CAMERA SW OUT

!0

  REC START IN

!1

  GND

11

10

9

5

4

3

2

1

5±2ms

0~0.4V

4.5~5.5V

Содержание AVR30

Страница 1: ...tely Mode d emploi Des performances optimales et un fonctionnement long terme seront assur s en appliquant les pr sentes instructions apr s avoir enti rement lu ce mode d emploi Manual de instruccione...

Страница 2: ...he recorder is received the unit must be connected to power source for 48 hours to assure the battery has been ad equately charged FOR YOUR SAFETY 2 PRECAUTIONS 2 IMPORTANT SAFEGUARDS 3 CONTROLS AND F...

Страница 3: ...for a log period and it is not intended to use the unit it is rec ommended that the unit be completely switched off by removing the plug Illustrated below is molded on the back of your unit CAUTION TO...

Страница 4: ...ots and openings in the cabinet are pro vided for ventilation to ensure reliable operation of the video product and to protect it from overheating These openings must not be blocked or covered The ope...

Страница 5: ...a or cable system This will prevent damage to the video product due to lightning and power line surges SERVICE 17 Servicing Do not attempt to service this video product yourself as opening or removing...

Страница 6: ...h the UP DOWN buttons 10 DOWN BUTTON Press to decrement change or reverse to the previous lower value 11 UP BUTTON Press to increase change or advance to the next higher value 12 V POS VERTICAL POSITI...

Страница 7: ...TIME FUNCTION on page 14 for details 23 RECORD BUTTON Press to start recording 24 STOP BUTTON Press to stop the tape The STOP button must be pressed to end the RECORD and PLAY mode 25 PLAY BUTTON Pre...

Страница 8: ...in the following cases A cassette is not loaded A cassette without its safety tab is loaded The timer has not been programmed 35 LOCK INDICATOR LOCK appears when the recorder is in the security lock...

Страница 9: ...other recorder Line 8 dBm 50 Kohm unbalanced 43 AUDIO OUT Provides an audio output for a monitor or another recorder 9 dBm 600 ohm unbalanced 44 EXTERNAL INTERFACE 15 PIN JACK Connect an alarm switch...

Страница 10: ...t the switcher output to the Video IN BNC terminal Because mul tiple camera systems require synchronization use of cameras having line locked vertical sync or a gen locked master drive sync source is...

Страница 11: ...ND RE REC in the RECYCLE FUNC TIONS menu in the ALARM SET display or you have selected REWIND STOP IF ALARM and no alarm recording has been made The output impedance is approx 100 ohm TAPE END RST The...

Страница 12: ...when the safety tab is removed Notes The TAB indicator lights when a cassette without its safety tab is loaded To record again on a cassette that has its safety tab removed cover the tab hole with ta...

Страница 13: ...appears on the monitor screen when the power cord is first plugged in SELECTING A FUNCTION TO BE PROGRAMMED The program menu will always begin with the CLOCK SET function followed by the TIMER SELECTI...

Страница 14: ...12 Press the START STOP button the seconds will start counting and the clock will start CLOCK SET will flash on off again at this time 13 To display the time date you have set here on the monitor scr...

Страница 15: ...bove buttons Note Summer time cannot be set unless TIME DATE is displayed 1 Press the START STOP button twice so that OPTIONS flashes on off 2 Press the SET button so that the OSD TYPE set ting flashe...

Страница 16: ...tor 15 Press the SET button The other program event location of MON flashes on off 16 Press the UP or DOWN button until the desired program number appears on the monitor Notes If you do not need to ti...

Страница 17: ...me start time the program number with the longest stop time has priority To correct information 1 Press the START STOP button 2 Press the UP or DOWN button repeatedly until the item to be corrected Pr...

Страница 18: ...hich pulses are output to switch the camera 18 The pulses are output during recording at 18 or a longer speed ALL The pulses are output during recording in all modes 06 ONLY The pulses are output duri...

Страница 19: ...keep sounding if recording is abnormal Buzzer will not sound even if recording is abnormal ALARM OUT ON or OFF To specify whether buzzer turns on or off when alarm is output ON OFF Buzzer will keep s...

Страница 20: ...ot operate 1 Press the START STOP button The duration set ting flashes on off 2 Press the UP or DOWN button until the desired setting appears on the monitor MANUAL 5 15 30 SEC 1 3 5 10 30 60 MIN TAPE...

Страница 21: ...s press the ALARM RESET button to clear the ALARM memory Notes When the ALARM RESET button is pressed once if PL is flashing PL will disappear Press the button again to clear the ALARM memory When PL...

Страница 22: ...ures are being recorded normally or not during recording When the PLAY button is pressed during recording the recorded picture is played back for several sec onds Then recording will continue AUTO REC...

Страница 23: ...ate the ALARM recording in the stop mode follow the TAPE RECORDING procedure step 1 then select YES of the ALARM READY menu in the ALARM SET display MASTER SYSTEM RESET Press the two reset buttons sim...

Страница 24: ...button again to resume normal playback Notes The visual search speed can be changed using the SELECTION MENU screen The playback picture will have some noise in the visual search mode ALARM INDEX SEAR...

Страница 25: ...e TRACKING control may need to be returned to center position if previously adjusted The TRACKING control is only active at the 06 A18 or A30 speed Replace cassette Clean video heads Remove cassette a...

Страница 26: ...Output 1 Vp p 75 ohm unbalanced BNC S N Ratio Video More than 42 dB 06 mode S N Ratio Audio More than 40 dB 06 mode Horizontal Resolution Colour 300 lines 06 mode Monochrome 350 lines 06 mode Audio I...

Страница 27: ...26 ENGLISH...

Страница 28: ...asco Milano Italy 39 02 4571791 ADEMCO Sontrix Espana Vivero 5 28040 Madrid Spain 34 91 533 4706 Security House Amperestraat 41 1446 TR Purmerend Netherlands 31 299 419 000 Video Controls Ltd Aston Fi...

Отзывы: