background image

– 3 – 

Operating the Buttons 

To Activate a Function 

To activate a programmed function, press and hold the associated button down until the yellow LED flashes; then release it.

 

System Status Indications Table 

LED 

LED Condition 

Speech 

System Status 

System Armed Away 

Armed Away or Maximum 

On Steady 

System Armed Stay 

Armed Stay or Instant 

Fire Fire Zone (Faulted Zone) 

Fire Alarm in progress 

Alarm Alarm Zone (Faulted Zone) 

Armed, Burglary Alarm in progress 

Red 

Flashing 

Alarm Alarm Zone (Faulted Zone) 

Alarm Memory 

On Steady 

System Disarmed Ready To Arm 

Disarmed, Ready to Arm 

Green 

Flashing 

System Disarmed Not Ready To Arm  System Not Ready, Zones Faulted 

Yellow  (Right) 

Flashing 

–– 

Indicates RF transmission (Non encrypted) 

Yellow (Left) 

Flashing 

–– 

Indicates RF transmission (encrypted) 
In Enter House ID Mode 
In Enable or Disable Encryption Mode 

Red & Green 

Alternately 
Flashing 

–– 

In Set Volume Level Mode 

System AC Loss 

AC Loss Condition 

N/A N/A 

Low Battery 

Low Battery Condition 

To Request System Status

 

Because the 5804BDV is a two-way device, users can check 
the system status before arming or disarming their system. To 
check system status, press and release any button 
momentarily.  The yellow LED will flash after you release the 
button.  After a second or two, the 5804BDV will display the 
system status information using a combination of LED and 
sounder activity (see the System Status Indications Table).  If 
5804BDV does not receive system status information from the 
panel for approximately 5 seconds, it will shut itself down.  It will 
also shut itself down if there is no button activity within 5 
seconds of receiving a status update. 

WARNING!

 

 

This device may not receive the system status 
properly if it operates within a few feet of the 
5881 RF receiver.

 

Multiple Button Operations

 

WARNING!

 

 

 

The 5804BDV should not be used for 24-hour 
silent alarm, as the unit itself is not silent.

 

 

The 5804BDV can generate the same responses as keypad 
panic key pairs of [

] + [#] and [

] + [

1

] by depressing “

A

” + “

C

” 

and “

B

” + “

D

” button pairs, respectively.   

 

You must depress the button pair for at least 2 seconds for the 
5804BDV to recognize the button pair command.  These button 
pairs allow the user to activate panic, fire, and medical alarms 
depending on control panel programming. 

 

5804BDV-005-V0

A + C Button Pair

B + D Button Pair

 

 

 

Low-Battery Indication 

When the unit goes into a low battery condition, the yellow 
LED will not flash when a button is pressed.  Change both 
batteries immediately. Refer to instructions in “To 
Install/Replace Batteries” paragraph on first page. 

 

Specifications

 

Physical: 

Belt Clip: 

4.1H x 2.2”W x 0.8”D 

 Transmitter: 

3.9”H x 2.0”W x 0.69”D 

Battery:

 

Maxell CR2430 or Duracell DL2430

 

FOR LIMITATIONS OF THE ENTIRE ALARM SYSTEM, REFER TO THE INSTALLATION INSTRUCTIONS FOR THE 
CONTROL WITH WHICH THIS DEVICE IS USED. 

 

FCC STATEMENT

 

This device complies with Part 15 of the FCC rules.  Operation is subject to the following two conditions:  (1) 
This device may not cause harmful interference, and (2) This device must accept any interference received, 
including interference that may cause undesired operation. 

FCC ID.CFS8DL5804BDV 

 

Отзывы: