ADEMCO 5804BDV Скачать руководство пользователя страница 2

– 2 – 

To View the House ID  

1.  Enter House ID mode as described in step 1 (previous 

page).   

2. Depress 

the 

D

” button to view. 

3. 

The unit will display the stored number as described in 
step 4 (previous page). The unit will then exit House ID 
mode.

 

Programming a House ID in the Alarm 
Control 

x

On VISTA-40, 50P, 100, and above, use Device 
Programming mode to enable the RF receiver and enter 
the House ID number. 

x

On VIA-30PSE, VISTA-20SE, and below, go to field 

24

 

and enter the House ID number. 

 

Programming the Buttons 

Each 5804BDV is assigned a unique serial number during 
manufacture.  Each button on the unit also has a unique 
“loop” number that must be programmed into the alarm control 
during installation. Assign each button to an individual zone 
number and program the Input Type as “BR” (Button Type 
RF) by entering “

5

” in the control’s Zone Programming mode. 

Then, input the serial number by one of the following 
methods:   

x

Transmit twice from the device by pressing one of the 
buttons when prompted for the serial number. 

x

Enter the serial number manually through the keypad.  

x

Enter the serial number through V-LINK or Compass 
downloader software as applicable.   

Be sure to include the loop number of each button during 
programming (see loop assignments on previous page). 

    

 

NOTE:

 Do not use the 5804BDV for 24-hour silent alarm, as 

the unit itself is not silent. 

Button C 

If you choose 

not

 to use the “

C

” button, you must do the 

following to avoid a  “Check” condition when the button is 
accidentally pressed: 

1.  Assign this button to a zone. 

2.  After the serial number has been programmed, re-enter 

Zone Programming for that zone. 

3. At 

the 

“Zone Type” prompt, enter 

00

 and press [

].   

a)  On VIA-30 controls and below, the system will ask 

whether you want to permanently delete that zone.  
Enter 

0

 (No).  This will cause the system to retain the 

serial number, but render the button inactive.   

b) 

On VISTA-40 and above, continue to press [

] until 

you see the “Enter Zone No?” prompt again.  At this 
point, Press 

00

 and [

]. Then press 

99

 to exit 

Program mode.

 

On VISTA-40 and Above

 

If a button is assigned to zone type 20 (Arm Stay), 21 (Arm 
Away), or 22 (Disarm), you must assign a user to the button in 
order for it to operate. 

To assign a user number to the Arm/Disarm button: 

1.  Enter [4-digit User Code] + 8 + [User No.] + [4-digit new 

User Code]. 

2.  Answer Yes or No to the “Open/Close Report?” question. 

3.  Answer Yes to the “RF Button?” question. 

4. Enter the zone number assigned to the Arm/Disarm 

button. The keypad will show the summary of user 
information on its display. 

5.  Test the Arm/Disarm button to make sure it operates 

correctly. 

Activating High-Security Mode  

 

 

 

In order to activate this device in High-Security 
mode you must use a 5881EN receiver.  

 

1.  Program the 5804BDV in Zone Programming mode as 

usual. 

2.  After programming the unit, exit Zone Programming 

mode. 

3.  Enter Go/No Go mode at the control panel (see the 

control panel Installation Instructions for specific 
information.) 

4.  Press and hold the “B”, “C”, and “D” buttons at the same 

time until the unit’s red and green LEDs flash alternately. 
The 5804BDV transmits a special signal to the receiver. 
After 2 seconds, the unit will shut down. The unit is now 
in High-Security mode. 

 

 

After activating High-Security mode, Whenever a 
button on the unit is pressed, the left yellow LED 
flashes to indicate that the unit is in High-Security 
mode. If the left yellow LED does not flash when a 
button is pressed, repeat steps 3 and 4 above

 

Deactivating High-Security Mode 

Press and hold the “A”, “C”, and “D” buttons at the same time 
until the unit’s red and green LEDs flash alternately. After 2 
seconds the 5804BDV will shut down and is no longer in 
High-Security mode. When the unit is not in High-Security 
mode, pressing any button will cause the right yellow LED to 
flash. 

Adjusting Volume Level  

This unit is shipped with the volume set to the lowest level. To 
adjust the volume, proceed as follows:  
1.  Enter the Volume Level Programming mode by pressing 

and holding the “A”,  “B”, and “D” buttons simultaneously 
until the unit’s red and green LEDs flash alternately.  
Note that if no button is pressed for 5 seconds the unit 
will automatically shut down and no change to the volume 
level is made. 
a. Press 

the 

“A” button for low volume level, or 

b. Press 

the 

“B” button for medium volume level, or 

c. Press 

the 

“C” button for maximum volume level. The 

word  “Alarm” will be heard at the volume level 
selected. 

2.    Press the “D” to accept. 

 

 

Volume level affects the life of the battery. Use low 
volume for maximum battery life. 

 