2
4208U-SOC-V0
NOTE
FOR CE INSTALLATIONS A
N6361 EMI SUPPRESSION
BEAD IS REQUIRED.
1 2 3 4 5
4208U
NOT
USED
( ) GROUND
(+) 12V
( )
(+)
TO
POLLING
LOOP
(USE
TWISTED
PAIR)
1
2
3
5
4
1
3
7
6
8
5
4
2
9
10
11 12
TB2
TB1
REED (TAMPER) SWITCH
10k 10k
10k 10k
10k 10k
10k 10k
LOOPS: A
B
C
D
E
F
G
H
(EACH LOOP’S MAX
RESISTANCE:
300 ohms + 10k EOLR)
7
8
ON
1
DIP Switches
1 2 3 4 5
ON
6
7
ON
ON
OFF
SIDEVIEW
POSITIONS 2-5: SELECT THE 8 SENSOR
DEVICE GROUP ADDRESS
(SHOWN ON, ON, ON,
OFF = 2nd GROUP SELECTION).
POSITION 6:
DEVICE TYPE (SHOWN
ON = “SERIAL NUMBER MODE”).
POSITION 7:
NOT USED (SET TO “OFF”).
8
}
ON
1
POSITION 1:
SELECT RESPONSE TIME
FOR LOOPS A and B
(SHOWN ON = SLOW).
POSITION 8:
SELECT TAMPER PROTEC-
TION SETTING (SHOWN
“OFF” = TAMPER ENABLED).
}
4208U-001-V0
Figure 2: Summary of Connections
For “Zone Assignment” mode, DIP Switch position 6 must be off.
When using this mode, program each zone’s “Input Type” as “DIP Switch Polling Loop Device” (DP), where applicable.
THIS SWITCH SETTING PRESETS THE LOOPS TO THESE ZONE NUMBERS
DIP Switch Position
(“-” Means “off”)
Loop Designations
2 3 4 5 6 A B C D E F G H *
On On On On - 1
2
3
4
5
6
7
8 **
On On On - - 9 10 11 12 13 14 15 16
On
On - On - 17 18 19 20 21 22 23 24
On
On - - - 25 26 27 28 29 30 31 32
On - On
On - 33 34 35 36 37 38 39 40
On - On - - 41 42 43 44 45 46 47 48
On - - On - 49 50 51 52 53 54 55 56
On - - - - 57 58 59 60 61 62 63 64
- On
On
On - 65 66 67 68 69 70 71 72
- On
On - - 73 74 75 76 77 78 79 80
- On - On - 81 82 83 84 85 86 87 88
- On - - - 89 90 91 92 93 94 95 96
-
- On On - 97 98 99 100 101 102 103 104
-
- On - - 105 106 107 108 109 110 111 112
-
-
- On - 113 114 115 116 117 118 119 120 ***
-
-
-
- - 121 122 123 124 125 126 127 N/A
Zone N
u
mber
*Do not select 1 – 8 for VISTA controls.
**If 9 – 16 is selected for controls that have 9 hardwire zones. Loop A (Zone 9) will be inactive.
***Accommodates option “ONE 4208 IN USE” if referred to in control programming.
NOTE: Consult the Control Panel Instructions to determine the valid zone numbers for that control panel.
Table 1. 4208U Zone Assignments
THIS SWITCH SETTING PRESETS THE LOOP TO THESE SERIAL NUMBERS
DIP Switch Position
(“-” Means “off”)
Loop Designation
2
3
4
5
6
LOOP A
LOOP B
LOOP C
LOOP D
LOOP E
LOOP F
LOOP G
LOOP H
ON
ON
ON
ON
ON 000-4116 000-4117 000-4118 000-4119 000-4124 000-4125 000-4126 000-4127
ON
ON
ON
-
ON 006-9908 006-9909 006-9910 006-9911 00
6
-9916 0
06
-9917 00
6
-9918 00
6
-9919
ON
ON
-
ON
ON 013-9812 013-9813 013-9814 013-9815 013-9820 013-9821 013-9822 013-9823
ON
ON
-
-
ON 020-9716 020-9717 020-9718 020-9719 020-9724 020-9725 020-9726 020-9727
ON
-
ON
ON
ON 027-9620 027-9621 027-9622 027-9623 027-9628 027-9629 027-9630 027-9631
ON
-
ON
-
ON 034-9524 034-9525 034-9526 034-9527 034-9532 034-9533 034-9534 034-9535
ON
-
-
ON
ON 041-9428 041-9429 041-9430 041-9431 041-9436 041-9437 041-9438 041-9439
ON
-
-
-
ON 048-9332 048-9333 048-9334 048-9335 048-9340 048-9341 048-9342 048-9343
-
ON
ON
ON
ON 055-9236 055-9237 055-9238 055-9239 055-9244 055-9245 055-9246 055-9247
-
ON
ON
-
ON 062-9140 062-9141 062-9142 062-9143 062-9148 062-9149 062-9150 062-9151
-
ON
-
ON
ON 069-9044 069-9045 069-9046 069-9047 069-9052 069-9053 069-9054 069-9055
-
ON
-
-
ON 076-8948 076-8949 076-8950 076-8951 076-8956 076-8957 076-8958 076-8959
-
-
ON
ON
ON 083-8852 083-8853 083-8854 083-8855 083-8860 083-8861 083-8862 083-8863
-
-
ON
-
ON 090-8756 090-8757 090-8758 090-8759 090-8764 090-8765 090-8766 090-8767
-
-
-
ON
ON 097-8660 097-8661 097-8662 097-8663 097-8668 097-8669 097-8670 097-8671
-
-
-
-
ON 104-8564 104-8565 104-8566 104-8567 104-8572 104-8573 104-8574 104-8575
Table 2. 4208U Serial Number Assignments