Housing and connections 

The connections to mains adapter, serial port and to the load cells are located at the back of the ADE display. 
The set-up switch to start the configuration mode is underneath the housing. It is protected by a cover plate and 
secured by a screw (not shown in Fig. 2-1).  

Do not use the set-up button, as otherwise calibration will be lost. This procedure is only allowed 
by authorized service personnel appointed by ADE (GmbH  & Co.). Any unauthorized manipula-
tions made to the configuration mode will affect the warranty agreement. 

 

 

 

 

 
 
 

Safety 

The ADE-display unit (MAK) corresponds to the latest state of the art technology and complies with standard 
regulations  and  directives.  Kindly  follow  the  safety  instructions  in  this  operating  manual,  the  country-specific 
installation standards as well as the applicable safety conditions and accident prevention regulations in all as-
pects.  Electronic medical devices are restricted to special safety regulations in respect of their electromagnetic 
compatibility. For positioning and operation, follow the instructions of this operation manual. 

– 

Portable and mobile HF-communication systems may influence electronic medical devices. 

– 

Make sure that the mains cable does not pose any potential trip hazard. 

– 

Do not drop the weighing bridges/shoes or subject them to violent shocks. 

– 

Do not operate the unit in hazardous or unstable conditions. 

– 

Do not dip or submerge the unit into water or other liquids. 

– 

Have all repairs and calibration carried out by professional personnel authorised by ADE. 

– 

Set up the unit as far away as possible from equipment that generates electromagnetic or other interfer-
ence. 

– 

Only use original rechargeable batteries and mains adapter from ADE. The warranty does not cover any 
damage caused by using other types of batteries or charger units. 

 
Safe operation is no longer guaranteed: 

If the power unit shows visible damage. 

If the power unit is not working properly. 

After longer periods of storage in damp areas. 

In these cases, contact your service partner for your own safety! 

 

Settings 

The following functions are available in setting mode: 

– 

Configuration of the serial interface 

– 

Set up of date, time and consecutive printout numbers  

– 

Set up of print format 

– 

Set up of switching points 

– 

Test functions 

 

Содержание M600620

Страница 1: ...Operating Manual Electronic Bed Scale M600620 M600620 210422 Rev006 UM e...

Страница 2: ...2 M600620 210422 Rev006 UM e...

Страница 3: ...evices 6 Housing and connections 7 Safety 7 Settings 7 Setting date and time 8 Operation 8 Modes of operation 8 Before weighing 9 Weighing 9 Tare function 9 Hold function 10 Determining the Body Mass...

Страница 4: ...dry place Dismantle packaging and foil carefully and remove the transport securing de vices Place the weighing feet on a plain dry and level surface before the weighing procedure Scope of delivery 4 W...

Страница 5: ...nds on the frequency of use temperatures settings and the accessories being used New batteries or batteries that have been stored for a long period require a longer charging period Charge the batterie...

Страница 6: ...able for CE approved class III scales 13 Number pad Figures 0 9 Clear Enter and Navigation functions Key 6 menu direction to the right Key 4 menu direction to the left Key 8 menu direction down Key 2...

Страница 7: ...positioning and operation follow the instructions of this operation manual Portable and mobile HF communication systems may influence electronic medical devices Make sure that the mains cable does no...

Страница 8: ...ENTER key and set the minutes and seconds Go back by pressing key 2 TIME appears on the display Press key 6 one time and DATE appears on the display like the time entry Press key 2 two times and EXIT...

Страница 9: ...displayed press the TARE key 9 to reset the display back to zero The display changes to net mode NET status indicator 5 is on and shows zero Note Taring the bed with subsequent determination of the pa...

Страница 10: ...AR key After the entry has been confirmed by the ENTER key the BMI value will be calculated using the weight on the scales The display changes between weight value and BMI value b xx x every two secon...

Страница 11: ...ording to legal regulations of your specific country Please make sure that only discharged batteries or batteries with insulated poles are disposed of as otherwise they may short circuit Storage and t...

Страница 12: ...12 M600620 210422 Rev006 UM e...

Страница 13: ...t Full duplex RS 232 38400 19200 9600 4800 2400 1200 bps Printer Port Output only RS 232 or active 20 mA current loop 9600 4800 2400 1200 bps Both Ports 7 or 8 data bits even odd or no parity Operator...

Страница 14: ...scales have been manufactured in accordance with the harmonised European standards They conform to the regulations of the EC directives listed below EMC Directive 2014 30 EU Low Voltage Directive 2014...

Страница 15: ...M600620 210422 Rev006 UM e 15...

Страница 16: ...16 M600620 210422 Rev006 UM e Dealer...

Отзывы: