Introduction 

 

This  symbol  means:  "Consult  operating  instructions".  To  achieve  accurate  results,  read  the 
instructions for use carefully before use and follow all instructions provided therein. Keep the 
instructions for use for future reference. 

 

Your ADE electronic bed-scale is a quality, sturdy and durable product manufactured under the high standards 
and regulations for calibrated class III scales in accordance with national regulations in Germany. The scale 

is 

designed and manufactured primarily for the daily practice in hospitals and dialysis centres.

  

ADE instruction manuals have been prepared to provide the user with all the necessary knowledge about the 
safe use of ADE scales and their related accessory equipment.  

For further questions about how to use the products or about this or other service manuals, feel free to contact 
your local ADE representative or visit our web page at www.ade-hamburg.de  

In order to achieve the best possible results kindly read and follow the operation manual in all respects. 

Assembly and set up 

The ADE bed scale is supplied in a fully assembled condition. Please insure that your scale is being placed 
vibration-free at a dry place. Dismantle packaging and foil carefully and remove the transport securing de-
vices. Place the weighing feet on a plain, dry and level surface before the weighing procedure. 

Scope of delivery 

–  4 Weighing shoes/ measuring feet with integrated ramp (numbered 1-4) 

–  4 Locking aids 

–  1 Mains adapter 

–  Equipment trolley with integrated terminal box for connection to weighing shoes (numbered 1-4) and already 

mounted indicator 

–  Operating Manual including “Certificate of Conformity” 

Power supply 

Power is supplied either by the rechargeable battery in the display unit or by the mains power via the supplied 
power unit. The imprinted voltage value at the mains adapter must match the mains voltage at the place of use. 
Connect the mains cable to the indicator and to a socket.  

The wall socket must be located near to the unit and be easily accessible. Please use only the mains adapter 
supplied by ADE. The mains adapter is charging the battery pack during normal operation.  

When the battery is being charged for the first time a sufficient charging period of approx. 24 hours is necessary 
to achieve a full battery load. 

If the unit is in battery mode and the display indicates – 

Lo

, the battery needed to be recharged with the mains 

adapter. For a full battery load a charging period of 12-16 hours is required with the scale being switched off. If–

Lo

 still appears at the display inform your service partner. 

Содержание M600620

Страница 1: ...Operating Manual Electronic Bed Scale M600620 M600620 210422 Rev006 UM e...

Страница 2: ...2 M600620 210422 Rev006 UM e...

Страница 3: ...evices 6 Housing and connections 7 Safety 7 Settings 7 Setting date and time 8 Operation 8 Modes of operation 8 Before weighing 9 Weighing 9 Tare function 9 Hold function 10 Determining the Body Mass...

Страница 4: ...dry place Dismantle packaging and foil carefully and remove the transport securing de vices Place the weighing feet on a plain dry and level surface before the weighing procedure Scope of delivery 4 W...

Страница 5: ...nds on the frequency of use temperatures settings and the accessories being used New batteries or batteries that have been stored for a long period require a longer charging period Charge the batterie...

Страница 6: ...able for CE approved class III scales 13 Number pad Figures 0 9 Clear Enter and Navigation functions Key 6 menu direction to the right Key 4 menu direction to the left Key 8 menu direction down Key 2...

Страница 7: ...positioning and operation follow the instructions of this operation manual Portable and mobile HF communication systems may influence electronic medical devices Make sure that the mains cable does no...

Страница 8: ...ENTER key and set the minutes and seconds Go back by pressing key 2 TIME appears on the display Press key 6 one time and DATE appears on the display like the time entry Press key 2 two times and EXIT...

Страница 9: ...displayed press the TARE key 9 to reset the display back to zero The display changes to net mode NET status indicator 5 is on and shows zero Note Taring the bed with subsequent determination of the pa...

Страница 10: ...AR key After the entry has been confirmed by the ENTER key the BMI value will be calculated using the weight on the scales The display changes between weight value and BMI value b xx x every two secon...

Страница 11: ...ording to legal regulations of your specific country Please make sure that only discharged batteries or batteries with insulated poles are disposed of as otherwise they may short circuit Storage and t...

Страница 12: ...12 M600620 210422 Rev006 UM e...

Страница 13: ...t Full duplex RS 232 38400 19200 9600 4800 2400 1200 bps Printer Port Output only RS 232 or active 20 mA current loop 9600 4800 2400 1200 bps Both Ports 7 or 8 data bits even odd or no parity Operator...

Страница 14: ...scales have been manufactured in accordance with the harmonised European standards They conform to the regulations of the EC directives listed below EMC Directive 2014 30 EU Low Voltage Directive 2014...

Страница 15: ...M600620 210422 Rev006 UM e 15...

Страница 16: ...16 M600620 210422 Rev006 UM e Dealer...

Отзывы: