ADE LWX200 Series Скачать руководство пользователя страница 4

LWX200-210408-Rev003-UM-en 

 

-  Place the scale as far as possible from other devices or sources that generate 

electromagnetic field or other interferences (e.g. strong motors and portable and mobile HF 
communication devices) as these can falsify the measurement results. 

-  Use only approved accessories and peripherals.  

-  Before cleaning the device, pull the mains adapter/plug out of the socket. 

-  Never clean the scale with abrasive or aggressive cleaning agents. 

-  Do not immerse the device in water or other liquids. 

-  If you have problems with this device, e.g. when setting up, maintaining or using, please 

contact the authorised customer service. Do not open or repair the device yourself. 

-  Please notify the authorised customer service if unexpected operations or events occur. 

-  If the weighing system is not used for a longer period of time, it should be cleaned and 

stored in a protective film. The addition of a drying agent is desirable. 

 

DO NOT use the scale: 

-  If the mains adapter is damaged; 

-  If the mains adapter is not working; 

-  If the battery compartment has an unnatural bulge; 

-  After long storage in a humid environment. 

In such cases, please contact authorised customer support. 

4.  Intended use 

Your ADE scale is a quality product and was manufactured for use as a non-automatic scale. 
The scale is used to determine the weight and price of goods to be weighed and is intended for 
use in supermarkets, grocery stores, retail stores, markets and similar areas of application. 

To  determine  the  weight  and  price,  carefully  place  the  item  to  be  weighed  as  centrally  as 
possible on the scale. The scale may be loaded with the maximum load (Max) specified on the 
device and on the nameplate. After a stable measurement result has been determined, it can 
be read off. 

The scale must not be used for dynamic weighing. If small quantities are slowly added or 
removed (e.g. filling liquids), this can lead to incorrect measurement results. 

The device may only be used as intended. All applications of the device that are not mentioned 
in  the  chapter  “Intended  use”,  as  well  as  non-observance  of  the  safety  instructions,  are 
considered improper use. It is the user of the device, but not the manufacturer, who assumes 
liability for any resulting damage to property or personal injury resulting from misuse. 

The use of accessories other than the original accessories supplied by the manufacturer may 
void this warranty. 

 

The weighing system may only be used for legal-for-trade weighing if it is 
verified. The verification is invalid without a seal. 

This device may not be modified without the manufacturer's permission. 

 

 

 

Содержание LWX200 Series

Страница 1: ...OPERATING MANUAL Electronic price computing retail scales Retail scale LWX200 series LWX200 210408 Rev003 UM en...

Страница 2: ...status indicator 9 8 Using the scale 10 Preliminary Note 10 Switching the scale on and off 10 Reset 10 Price entry 10 Taring 11 Saving and retrieving article prices and or tare values 11 Saving direc...

Страница 3: ...for everyone When reselling the scale the operating manual must also be supplied Target group This operating manual is intended for personnel who are responsible for setting up operating care and main...

Страница 4: ...DE scale is a quality product and was manufactured for use as a non automatic scale The scale is used to determine the weight and price of goods to be weighed and is intended for use in supermarkets g...

Страница 5: ...f the scale and the other end to the local power supply In this case before connecting the supplied mains adapter to the scale make sure that the voltage on the nameplate matches the local power suppl...

Страница 6: ...attention to the correct positioning of the column parts upper and lower end 4 Put the display on the column and screw both with the enclosed countersunk screws 5 Insert the column into the column mo...

Страница 7: ...he object e g a container is tared by pressing it once and the scale switches from gross to net mode Taring is indicated by the NET symbol on the display FIX To activate or deactivate price and automa...

Страница 8: ...OFF On and off key The scale is switched on by pressing this key The scale is switched off again by pressing this key again Menu guidance keys Symbol Description Function TARE key For calling and conf...

Страница 9: ...e by piece amount Weight determination is not possible kg Display of the basic price unit per kilogramme 100g Display of the basic price unit per 100 grammes FIX Display for enabled fixed price functi...

Страница 10: ...off the scale Automatic deactivation of the scale The scale is equipped with a power saving function As a result the scale switches off after a period of time that can be set by the user see section 9...

Страница 11: ...e container from the scale together with the goods to be weighed As a net weight the scale shows the tared weight of the container as a negative value After unloading the platform and pressing the key...

Страница 12: ...Use the and keys to choose between price calculation based on the Unit price Amount Basic price per kg Weight kg and Basic price per 100 g Weight 100 g Confirm your entry by pressing the key The disp...

Страница 13: ...rieval for determination based on quantity To retrieve a direct PLU select one of the keys The display shows the data stored on the PLU Now enter the number of pieces to be calculated In addition to t...

Страница 14: ...ion based on the Unit price Amount Basic price per kg Weight kg and Basic price per 100 g Weight 100 g Confirm your entry by pressing the key The display now shows the entry of the unit or basic price...

Страница 15: ...retrieval for determination based on quantity To retrieve an indirect PLU press the key Use the keys to select the memory space 00 99 from which the data must be retrieved The display shows the data s...

Страница 16: ...settings Backlight setting The scale has three different backlight setting options OFF The backlight is switched off permanently MANUAL The backlight can be switched on and off by pressing the key AUT...

Страница 17: ...as F0 CAL and F14 GrA are blocked on calibrated scales A change leads to the loss of the calibration and is only reserved for qualified personnel authorised by the manufacturer Indicator Description F...

Страница 18: ...s not possible Zeroing is not possible if the displayed weight exceeds 2 of the capacity of the scale In this case switch the scale off and on again Error messages Failure Cause Measure ERR 4 Current...

Страница 19: ...e of accessories other than those approved by ADE especially batteries will void the warranty This warranty does not cover external normal wear and tear or damage caused by accident or misuse The warr...

Страница 20: ...for weight basic price and total price 9 5 mm high tare weight characters adjustable backlight Casing Stable plastic housing Keypad Easy care membrane keypad with acoustic key function control Functi...

Страница 21: ...ctive 2014 31 EU EMC Directive 2014 30 EU Low voltage directive 2014 35 EU RoHS Directive 2011 65 EU in their respectively applicable versions This declaration will lose its validity if any modificati...

Страница 22: ...22 LWX200 210408 Rev003 UM en...

Страница 23: ...LWX200 210408 Rev003 UM en 23...

Страница 24: ...24 LWX200 210408 Rev003 UM en Distributor...

Отзывы: