ADE LW300 Series Скачать руководство пользователя страница 5

LW300_LW300T-200520-Rev005-UM-en 

 

5.  Scope of delivery 

Check  the  delivery  contents  for  completeness  as  soon  as  you  receive  the  scale.  Carefully 
unpack the scale and accessories and remove all packaging materials. 

Included in the delivery are: 

-  Price computing scale 
-  LW300T series only: Foam cover and screw for fixing the high display 
-  Weighing platform 
-  Power supply unit 
-  Operating manual 
-  Declaration of Conformity 
-  Optional: Rechargeable battery 6V 4Ah (installed in the scale) 

 

 

On  verified  scales:  Check  the  identity  of  the  scale  serial  numbers  and  the 
declaration of conformity. This is a mandatory requirement to use the scale in 
legal metrology! 

6.  Start-Up the scale 

1.  Carefully unpack the scale and accessories and remove all packaging materials. 

2.  Remove the transportation lock on the bottom of the scale, if present on your model. The 

transportation locking device is identified by the labels below: 

            

 

 

Not  removing  the  transportation  lock  can  lead  to  incorrect  weighing 
results! 

3.  Place the scale on a level, stable surface. Do not place the scale on a shaky or vibrating 

table as this will cause distortion of measurement results. 

4.  Connect one end of the power supply to the power connector on the bottom of the scale 

and the other end to the local power supply. 

 

In this case, before connecting the supplied mains adapter to the scale, 
make sure that the voltage on the nameplate matches the local power 
supply. 

 

After the warm-up time (15 minutes), the scale is ready for use. 
The  warm-up  time  applies  to  every  disconnection  from  the  mains 
(except battery mode). 

5.  Align the scale using the support feet. Make sure that the air bubble of the spirit level is 

centred in the black frame. 

 

Check the horizontal position of the scale 
after every change of location! 

 

 

 

 

Содержание LW300 Series

Страница 1: ...il scale LW300 LW300T series LW300_LW300T 200520 Rev005 UM en ADE Germany GmbH Co KG Hammer Steindamm 27 29 22089 Hamburg GERMANY 49 0 40 432776 0 49 0 40 432776 10 info ade germany de OPERATING MANUA...

Страница 2: ...enu guidance keys 8 Display 8 Battery status indicator 9 8 Using the scale 9 Preliminary Note 9 Switching the scale on and off 9 Zero Setting 10 Price computing 10 Taring 10 Saving and retrieving arti...

Страница 3: ...s operating manual before using it for the first time 3 Safety instructions It is essential that you read understand and follow all instructions in these instructions for use as well as the country sp...

Страница 4: ...for use in supermarkets grocery stores retail stores markets and similar areas of application To determine the weight and price carefully place the item to be weighed as centrally as possible on the...

Страница 5: ...ock on the bottom of the scale if present on your model The transportation locking device is identified by the labels below Not removing the transportation lock can lead to incorrect weighing results...

Страница 6: ...placed in the centre of the weighing platform The goods to be weighed should not protrude beyond the weighing platform Assembling the tower display LW300T series only 1 Insert the stand of the high d...

Страница 7: ...o enter a double zero To adjust the backlight C Delete key Pressing this key deletes the last digit of basic price ZERO Zeroing key If this key is pressed the scale is returned to the zero position TA...

Страница 8: ...Display of the net weight of the item to be weighed 2 Display of the basic price per kg 3 Display of the total price determined from net weight and basic price Display symbols Symbol Meaning Display f...

Страница 9: ...8 Using the scale Preliminary Note Do not load the scale with weights that exceed the maximum capacity As soon as you perceive the signal for an overload this is shown by oL on the display immediatel...

Страница 10: ...displayed Carry out as many weighing operations as required As long as the tared container remains on the weighing platform only the net weighing results and the prices determined for them will be dis...

Страница 11: ...price shows the entered basic price and at the FIX symbol shows the activated FIX function If necessary you can now place your empty container on the weighing platform and tare it by pressing the key...

Страница 12: ...displayed as a negative value The fixed basic price remains on the display If you wish to store a new fixed tare weight press the key to delete the stored tare weight Place the new container to be tar...

Страница 13: ...t Cause Measure The display shows nothing The scale has switched off automatically Switch on the scale The scale is not connected to the mains Use the optional mains adapter to connect the scale to th...

Страница 14: ...h off the scale to avoid damage Disposal Waste electrical equipment do not belong in household waste Devices with this marking may not be disposed of as residual waste but must be recycled Remove if p...

Страница 15: ...or authorised personnel can perform recalibration On the CE mark you can find the year of initial calibration next to the notified body 0122 Recalibration must be carried out when one or more securit...

Страница 16: ...d Easy to clean 10 key membrane keyboard with 20 keys Functions Weighing taring price computing Fix function fixed price fixed tare 4 direct PLU 10 indirect PLU Automatic zero setting Overload display...

Страница 17: ...NAWI directive 2014 31 EU EMC Directive 2014 30 EU Low voltage directive 2014 35 EU RoHS Directive 2011 65 EU in their respectively applicable versions This declaration will lose its validity if any...

Страница 18: ...18 LW300_LW300T 200520 Rev005 UM en...

Страница 19: ...LW300_LW300T 200520 Rev005 UM en 19...

Страница 20: ...20 LW300_LW300T 200520 Rev005 UM en Distributor...

Отзывы: