-  Never clean the scale with abrasive or aggressive cleaning agents. 
-  Do not immerse the device in water or other liquids. 
-  If  you  have  problems  with  this  device,  e.g.  when  setting  up,  maintaining  or  using,  please 

contact the authorised customer service. Do not open or repair the device yourself. 

-  Please notify the authorised customer service if unexpected operations or events occur. 
-  If the weighing system is not used for a longer period of time, it should be cleaned and stored 

in a protective film. The addition of a drying agent is desirable. 

 
DO NOT use the scale: 
-  If the mains adapter is damaged; 
-  If the mains adapter is not working; 
-  If the battery compartment has an unnatural bulge; 
-  After long storage in a humid environment. 
In such cases, please contact authorised customer support. 

4.  Intended use 

Your ADE scale is a quality product and was manufactured for use as a non-automatic scale. 
The scale is used to determine the weight and price of goods to be weighed and is intended for 
use in supermarkets, grocery stores, retail stores, markets and similar areas of application. 

To  determine  the  weight  and  price,  carefully  place  the  item  to  be  weighed  as  centrally  as 
possible on the scale. The scale may be loaded with the maximum load (Max) specified on the 
device and on the nameplate. After a stable measurement result has been determined, it can 
be read off. 

The  scale  must  not  be  used  for  dynamic  weighing.  If  small  quantities  are  slowly  added  or 
removed (e.g. filling liquids), this can lead to incorrect measurement results. 
The device may only be used as intended. All applications of the device that are not mentioned 
in  the  chapter  “Intended  use”,  as  well  as  non-observance  of  the  safety  instructions,  are 
considered improper use. It is the user of the device, but not the manufacturer, who assumes 
liability for any resulting damage to property or personal injury resulting from misuse. 
The use of accessories other than the original accessories supplied by the manufacturer may 
void this warranty. 

 

The weighing system may only be used for legal-for-trade weighing if it is 
verified. The verification is invalid without a seal. 

This device may not be modified without the manufacturer's permission. 

 
 

 

Содержание LW300 Series

Страница 1: ...il scale LW300 LW300T series LW300_LW300T 200520 Rev005 UM en ADE Germany GmbH Co KG Hammer Steindamm 27 29 22089 Hamburg GERMANY 49 0 40 432776 0 49 0 40 432776 10 info ade germany de OPERATING MANUA...

Страница 2: ...enu guidance keys 8 Display 8 Battery status indicator 9 8 Using the scale 9 Preliminary Note 9 Switching the scale on and off 9 Zero Setting 10 Price computing 10 Taring 10 Saving and retrieving arti...

Страница 3: ...s operating manual before using it for the first time 3 Safety instructions It is essential that you read understand and follow all instructions in these instructions for use as well as the country sp...

Страница 4: ...for use in supermarkets grocery stores retail stores markets and similar areas of application To determine the weight and price carefully place the item to be weighed as centrally as possible on the...

Страница 5: ...ock on the bottom of the scale if present on your model The transportation locking device is identified by the labels below Not removing the transportation lock can lead to incorrect weighing results...

Страница 6: ...placed in the centre of the weighing platform The goods to be weighed should not protrude beyond the weighing platform Assembling the tower display LW300T series only 1 Insert the stand of the high d...

Страница 7: ...o enter a double zero To adjust the backlight C Delete key Pressing this key deletes the last digit of basic price ZERO Zeroing key If this key is pressed the scale is returned to the zero position TA...

Страница 8: ...Display of the net weight of the item to be weighed 2 Display of the basic price per kg 3 Display of the total price determined from net weight and basic price Display symbols Symbol Meaning Display f...

Страница 9: ...8 Using the scale Preliminary Note Do not load the scale with weights that exceed the maximum capacity As soon as you perceive the signal for an overload this is shown by oL on the display immediatel...

Страница 10: ...displayed Carry out as many weighing operations as required As long as the tared container remains on the weighing platform only the net weighing results and the prices determined for them will be dis...

Страница 11: ...price shows the entered basic price and at the FIX symbol shows the activated FIX function If necessary you can now place your empty container on the weighing platform and tare it by pressing the key...

Страница 12: ...displayed as a negative value The fixed basic price remains on the display If you wish to store a new fixed tare weight press the key to delete the stored tare weight Place the new container to be tar...

Страница 13: ...t Cause Measure The display shows nothing The scale has switched off automatically Switch on the scale The scale is not connected to the mains Use the optional mains adapter to connect the scale to th...

Страница 14: ...h off the scale to avoid damage Disposal Waste electrical equipment do not belong in household waste Devices with this marking may not be disposed of as residual waste but must be recycled Remove if p...

Страница 15: ...or authorised personnel can perform recalibration On the CE mark you can find the year of initial calibration next to the notified body 0122 Recalibration must be carried out when one or more securit...

Страница 16: ...d Easy to clean 10 key membrane keyboard with 20 keys Functions Weighing taring price computing Fix function fixed price fixed tare 4 direct PLU 10 indirect PLU Automatic zero setting Overload display...

Страница 17: ...NAWI directive 2014 31 EU EMC Directive 2014 30 EU Low voltage directive 2014 35 EU RoHS Directive 2011 65 EU in their respectively applicable versions This declaration will lose its validity if any...

Страница 18: ...18 LW300_LW300T 200520 Rev005 UM en...

Страница 19: ...LW300_LW300T 200520 Rev005 UM en 19...

Страница 20: ...20 LW300_LW300T 200520 Rev005 UM en Distributor...

Отзывы: