ADE LW300 Series Скачать руководство пользователя страница 16

16 

LW300_LW300T-200520-Rev005-UM-en 

 

11. Technical data 

Model:

 

LW300-6(T)

 

LW300-15(T)

 

LW300-30(T)

 

Maximum load: 

6 kg 

15 kg 

30 kg 

Digit display: 

1g<3kg>2g 

2g<6kg>5g 

5g<15kg>10g 

Minimum load: 

20g 

40g 

100g 

 

Weighing 
surface: 

265 x 205 mm stainless steel 

Dimensions: 

Flat version:  

285 x 375 x 115 mm 

Column version:  

285 x 375 x 515 mm 

Net weight: 

Flat version:  

2.8 kg / 3.4 kg (without / with accu) 

Column version: 

3.3 kg / 3.9 kg (without / with accu) 

Operating 
temperature: 

-10°C bis +40°C 

Display: 

Easy to read LCD display with 15 mm high characters 

white LED backlight, display backlight can be deactivated 

Housing: 

Stable plastic housing 

Keypad: 

Easy to clean 10-key membrane keyboard with 20 keys 

Functions: 

Weighing, taring, price computing 
Fix function (fixed price + fixed tare) 
4 direct PLU + 10 indirect PLU 
Automatic zero setting 
Overload display 
Battery level indicator (at low supply voltage) 

Price entry/display:  Min. price entry: 

Preiseingabe/-anzeige: 

Max. price entry: 

999,99 € 

Min. price display: 

1 Cent 

Max. price display: 

9.999,99 € 

Power Supply: 

Mains and battery operation 

Power supply: 100-240VAC, 50/60Hz 0.32A max., Output: 12VDC, 500mA 

Battery: 6V 4Ah lead battery, in battery operation up to approx. 70 operating 
hours 

Battery protection: 

Automatic switch-off after 30 minutes after the battery symbol lights up 

 
 
 
 

Spare parts: 

Battery 

H2323-001 

Battery compartment cover 

H2323-015 

Load plate 

H2317-012 

Cover hood 

H2323-020 

Power supply 

H2323-014 

Levelling feet 

H2323-011 

 

 

 

Содержание LW300 Series

Страница 1: ...il scale LW300 LW300T series LW300_LW300T 200520 Rev005 UM en ADE Germany GmbH Co KG Hammer Steindamm 27 29 22089 Hamburg GERMANY 49 0 40 432776 0 49 0 40 432776 10 info ade germany de OPERATING MANUA...

Страница 2: ...enu guidance keys 8 Display 8 Battery status indicator 9 8 Using the scale 9 Preliminary Note 9 Switching the scale on and off 9 Zero Setting 10 Price computing 10 Taring 10 Saving and retrieving arti...

Страница 3: ...s operating manual before using it for the first time 3 Safety instructions It is essential that you read understand and follow all instructions in these instructions for use as well as the country sp...

Страница 4: ...for use in supermarkets grocery stores retail stores markets and similar areas of application To determine the weight and price carefully place the item to be weighed as centrally as possible on the...

Страница 5: ...ock on the bottom of the scale if present on your model The transportation locking device is identified by the labels below Not removing the transportation lock can lead to incorrect weighing results...

Страница 6: ...placed in the centre of the weighing platform The goods to be weighed should not protrude beyond the weighing platform Assembling the tower display LW300T series only 1 Insert the stand of the high d...

Страница 7: ...o enter a double zero To adjust the backlight C Delete key Pressing this key deletes the last digit of basic price ZERO Zeroing key If this key is pressed the scale is returned to the zero position TA...

Страница 8: ...Display of the net weight of the item to be weighed 2 Display of the basic price per kg 3 Display of the total price determined from net weight and basic price Display symbols Symbol Meaning Display f...

Страница 9: ...8 Using the scale Preliminary Note Do not load the scale with weights that exceed the maximum capacity As soon as you perceive the signal for an overload this is shown by oL on the display immediatel...

Страница 10: ...displayed Carry out as many weighing operations as required As long as the tared container remains on the weighing platform only the net weighing results and the prices determined for them will be dis...

Страница 11: ...price shows the entered basic price and at the FIX symbol shows the activated FIX function If necessary you can now place your empty container on the weighing platform and tare it by pressing the key...

Страница 12: ...displayed as a negative value The fixed basic price remains on the display If you wish to store a new fixed tare weight press the key to delete the stored tare weight Place the new container to be tar...

Страница 13: ...t Cause Measure The display shows nothing The scale has switched off automatically Switch on the scale The scale is not connected to the mains Use the optional mains adapter to connect the scale to th...

Страница 14: ...h off the scale to avoid damage Disposal Waste electrical equipment do not belong in household waste Devices with this marking may not be disposed of as residual waste but must be recycled Remove if p...

Страница 15: ...or authorised personnel can perform recalibration On the CE mark you can find the year of initial calibration next to the notified body 0122 Recalibration must be carried out when one or more securit...

Страница 16: ...d Easy to clean 10 key membrane keyboard with 20 keys Functions Weighing taring price computing Fix function fixed price fixed tare 4 direct PLU 10 indirect PLU Automatic zero setting Overload display...

Страница 17: ...NAWI directive 2014 31 EU EMC Directive 2014 30 EU Low voltage directive 2014 35 EU RoHS Directive 2011 65 EU in their respectively applicable versions This declaration will lose its validity if any...

Страница 18: ...18 LW300_LW300T 200520 Rev005 UM en...

Страница 19: ...LW300_LW300T 200520 Rev005 UM en 19...

Страница 20: ...20 LW300_LW300T 200520 Rev005 UM en Distributor...

Отзывы: