4) Unscrew completely the black turning knob of the sharpening device supplied with each machine with
standard knife. Then lead the end of the thread visible now through the hole of the thickness-plate
from the side of the carriage, while pulling the last-slice-device a bit upwards to the right.
Then screw on the sharpening device by means of the turning knob in such a way the neck of the
sharpening device rests upon the upper edge of the thickness plate.
5) Switch on the motor and advance the sharpening wheel carefully with not too much expenditure of
force to the rotating blade by turning slightly to the right the slice thickness adjusting knob. The
contact must be affected in such a way that the sharpening wheel is also turning. Normally a few
seconds are sufficient to sharpen the blade in this manner.
6) Having finished sharpening, switch off the motor, take off the sharpening device and adjust the slice
thickness to zero again.
7) Clear blade and shaft of the last-slice-device thoroughly of adhering sharpening shavings with a cloth.
As the blade will not always be entirely free from fat, it is recommendable to clean the sharpening wheel with
pure benzene from time to time.
The sharpening operation must be performed by skilled personnel.
Never attempt to clean the blade whilst it is moving.
The sharpening device can no longer sharpen the blade once its diameter is worn down by 10mm.
8. CLEANING AND MAINTENANCE
-
The machine must be cleaned by fully trained personnel only.
-
Unplug the machine. Never stop the machine using the (stop) button only.
-
Two people are required to handle the machine, using the 4 feet as handholds.
-
The blade must be replaced when the distance between the blade guard and the actual blade is no more
than 6mm.
-
Only remove the blade using the proper blade-removal tool.
-
Be careful with the blade edge as it is very sharp.
-
The power supply cable must be replaced by skilled personnel only.
-
The cleaning of the slicer with harmful products liable to affect the health of either operators or customers
is strictly prohibited.
-
Use products with a degree of acidity (pH 7 -8).
Содержание Juwel 1
Страница 3: ...Juwel 200624 Rev010 UM en 2 0 FIGURES Fig 1 Fig 2 ...
Страница 4: ...3 Juwel 200624 Rev010 UM en Fig 3 Fig 4 A R Q locking mechanism ...
Страница 13: ...Juwel 200624 Rev010 UM en 12 13 WIRING DIAGRAMS 230V 400V ...
Страница 14: ...13 Juwel 200624 Rev010 UM en 14 EXPLODED VIEWS SOCKET Juwel 1 Juwel 2K SOCKET Juwel 2 Juwel 3 ...
Страница 15: ...Juwel 200624 Rev010 UM en 14 CARRIAGE MOUNTING Juwel 1 Juwel 2K CARRIAGE MOUNTING Juwel 2 ...
Страница 16: ...15 Juwel 200624 Rev010 UM en CARRIAGE MOUNTING Juwel 3 CARRIAGE Juwel 1 Juwel 2K Juwel 2 Juwel 3 ...
Страница 17: ...Juwel 200624 Rev010 UM en 16 ADJUSTMENT UNIT Juwel 1 Juwel 2K ADJUSTMENT UNIT Juwel 2 Juwel 3 ...
Страница 18: ...17 Juwel 200624 Rev010 UM en MOTOR UNIT 230V Juwel 1 Juwel 2K MOTOR UNIT 230V Juwel 2 Juwel 3 ...
Страница 19: ...Juwel 200624 Rev010 UM en 18 MOTOR UNIT 400V Juwel 1 Juwel 2K MOTOR UNIT 400V Juwel 2 Juwel 3 ...
Страница 21: ...Juwel 200624 Rev010 UM en 20 ...
Страница 22: ...21 Juwel 200624 Rev010 UM en ...
Страница 23: ...Juwel 200624 Rev010 UM en 22 ...
Страница 24: ...23 Juwel 200624 Rev010 UM en Distributor ...