ADE ESW10 Series Скачать руководство пользователя страница 8

 

ESW10-200206-Rev007-UM-en 

Counting programme 

If containers are used, they must be tared beforehand in weighing mode. 

Place the reference piece count of the pieces to be counted on the scale. 

While  the  scale  is  displaying  the  weight,  pressing  the 

 key  activates  the  counting 

programme, at which point the scale displays “P 10” for a sample piece count of 10. In addition, 
the display shows “pcs”. 

You can change this piece count by pressing the 

 key. The display shows 10, 20, 50, 100, 

200 and then returns to 10 again each time it is pressed. 

Press  the 

 key  to  save  when  the  number  of  pieces  on  the  scale  matches  the  number 

displayed. 

If you now add more pieces, the display shows the number in pieces (pcs). 

Press the 

 key to switch between the piece count, piece weight and total weight. 

Press the 

 key to return to normal weighing mode. 

Weight control 

A control target weight or a control target weight range can be set on the scale. A beep sounds 
when it is reached or exceeded. 

The memory can be preset for a maximum and a minimum value. 

Preliminary remarks 

Enter the control target weight range 

Set the control target weight range by saving both a maximum and a minimum value. 

Take into account that there must be two different values where the maximum value must be 
higher than the minimum value. 

Enter the control target weight 

Set the control target weight by saving the same value for the maximum and minimum values. 

Control mode 2 

The scale checks whether the placed weight is within the limit values entered in the control target 
weight range or corresponds to the control target weight. 

If this is the case, the display shows “OK” and a beep sounds as long as the resulting weight is 
within these limits or corresponds to the control target weight. 

The scale checks whether the placed weight is outside the entered limit values of the control 
target weight range or does 

not

 match the control target weight. 

If this is the case, the display shows “OK” and a beep sounds as long as the resulting weight is 
outside these limit values or does not match the control target weight. 

 

 

Содержание ESW10 Series

Страница 1: ...W10 200206 Rev007 UM de ADE Germany GmbH Co KG Hammer Steindamm 27 29 22089 Hamburg GERMANY 49 40 432 776 0 Fax 49 40 432 776 10 Email info ade germany de OPERATING MANUAL READ BEFORE USE PLEASE KEEP...

Страница 2: ...splay elements 5 Operating elements 5 Display symbols 6 Battery status indicator Charging 6 9 Operation during weighing processes 6 Zeroing the scale 6 Taring 6 Counting programme 7 Weight control 7 A...

Страница 3: ...who operate the scale must have read and understood this operating manual before using it for the first time 3 Safety instructions It is essential that you read understand and follow all instructions...

Страница 4: ...ease contact authorised customer support 4 Intended use Your ADE ESW10 floor scale is a high quality product and was manufactured for use as a non automatic scale The scale is ideal as a precise fast...

Страница 5: ...e is exactly in the centre of the spirit level 10 First connect the power supply to the corresponding plug on the rear of the display device and only then connect to the mains Make sure that the suppl...

Страница 6: ...mode Taring is indicated by the TARE symbol on the display In counting mode it is used to select the reference piece count SAMPLE Piece count key Switches from weighing mode to counting mode In count...

Страница 7: ...is empty When the zero point is reached the display shows ZERO Taring Place the container to be tared on the scale pan and press the key The previously displayed weight of the container is saved and...

Страница 8: ...hen it is reached or exceeded The memory can be preset for a maximum and a minimum value Preliminary remarks Enter the control target weight range Set the control target weight range by saving both a...

Страница 9: ...The scale can be set so that additional weighings can be done manually by pressing the key The additional weighing function is only possible during the weighing process This function is not available...

Страница 10: ...ts Pressing the key increases the digits Confirm the set value by pressing the key Pressing the key cancels the process and exits the menu without saving Example When the display shows F0 H L press th...

Страница 11: ...ight EL on Backlight activated EL Au Backlight automatic EL off Backlight disabled EL Au bEEP Sets the beep function Control mode 2 Control mode 3 No beep F5 Prt Setting the RS232 interface for printi...

Страница 12: ...nit of weight No 1 This number indicates that a new value is saved in the memory at any time TOTAL 12 340 kg The total value stored If two blank lines If The total weight piece weight and piece count...

Страница 13: ...to the mains Weight display is unstable Draughts or air movements Close the window Choose a different location Vibrations Avoid vibrations Choose a different location Electromagnetic fields static ch...

Страница 14: ...mal display range Remove the overloading weight from the scale and make sure that the weighing platform is correctly positioned If the values remain unchanged this indicates that the measuring cell or...

Страница 15: ...will not apply for devices that have been opened by unauthorised persons The statutory rights of the customer are not affected by this agreement in any way The dealer from whom the scale was purchase...

Страница 16: ...2014 30 EU Low voltage directive 2014 35 EU RoHS Directive 2011 65 EC in their respectively applicable versions This declaration will lose its validity if any modification is made to the scale withou...

Страница 17: ...ESW10 200206 Rev007 UM en 16...

Страница 18: ...17 ESW10 200206 Rev007 UM en Distributor...

Отзывы: