ADE BA 833 Скачать руководство пользователя страница 6

                                                                          

 

   

                                

Thank  you  for  your  decision  to  purchase  this  high  quality  body  analyser  scale.  Please 
read this instruction manual prior to the start up and keep this user instruction careful so 
as to have this information on hand whenever it is needed. 

 

1. How does the body analyser work?

 

 
Through this new revolutionary scale you will be able to get information about your body 
composition with reference to your weight, body fat %, body water %, muscle mass %, 
bone mass and your daily calorie requirement.  First of all you have to enter once your 
personal  data  like  gender,  body  height  and  age  under  your  selected  personal memory 
location.  Afterwards  a measurement  is as  simple  as  on a  normal bathroom  scale.  You 
have  only  to  push  your  personal  memory  location,  step  on  the  scale  and  within  a  few 

seconds  your  measured  values  will  be  indicated.  The  analysis  is  based  on  the 
measurement  of  the  body’ s  electrical  resistance.  A  low,  safe  electrical  signal  passes 
freely  through  fluids  contained  in  lean  tissue,  such  as  muscle  and  blood,  but  meets 
resistance  passing  through  fat  tissue.  The  body  analyser  accurately  measures  the 
resistance and with reference to your personal data use it to calculate elements of body 
composition. 

 

2. Conditions to use

 

 
If possible the measurement should be done undressed but always barefoot. 
 
By  nature  a  body  is  subject  of  fluctuations  (for  example:  loss  of  water  after  taking 
exercise  or  after a  sauna  visit,  after  a  meal,  etc.).  To  enable comparable  readings  it  is 

important to take the measurements as possible always under the same conditions. 
 
In order to ensure that the results of analysis are accurate and consistent, please keep 
the  measurement  conditions  constant  always  at  the  same  daytime.  In  the  morning, 
directly after you’ ve woken up, your body will be dehydrated and also the majority of fluid 
will be stored in the central trunk area. This means that the resistance is relatively high 

because  of  the  poor  conductivity  in  the  body.  By  intensify  moving  during  the  day 
progresses the fluid becomes more evenly distributed through the limbs and increasing 
the accuracy of the readings. To get a realistic result it is important to take your readings 
at the same time and under the same conditions every day. The easiest way to stick the 
rule,  measure  always  in  the  morning,  15  minutes  after  you’ ve  got  up,  either  before  or 
after you’ ve gone to the bathroom. 
 

In spite of a very low electrical signal, this body ana lyzer is not suitable for persons 
with  hea rt  pacemaker  or  other  electronic  medical  implants!  There  is  no  risk  for 
persons with none electronic implant for instance a titanium plate in the knee. However, 
metal conducts the electric current extremely well and therefore the scale implicates the 
body  fat  value  “ beautified”   –   means  the  actual  body  fat  value  is  higher  as  indicated. 
However, tendencies may be determined as well. 

 

 

8. Error Messages 

 
“ Lo“   

Batteries are  used  up  - Please  replace  the  batteries  with  the intended 

 

 

type (1 x 9V). 

 
“ Err“   

Overload  -  The  weight  exceeds  the  maximum  capacity  of  200  kg. 

 

 

Please immediately remove the critical load to avoid load cell damage. 

 
“ Err ¯ 

L

“  

Low fat indication - Under 5% body fat is not possible to indicate. 

 
“ Err ¯ 

h

“   

High fat indication –  Over 75% body fat is not possible to indicate. 

 

“ C“  

Incorrect  weighing-  /  measuring  process  -  For  example,  the  scale  is

 

 

placed  unstable  or  you  do  not  remain  stationary  on  the  weighing 

 

 

platform. 

 

9. Technical Data

 

 

Capacity x graduation: 

max. 200 kg x 100 g 

Display resolution:  

body fat: 0.1% 

Display resolution:  

body water: 0.1% 

Display resolution:  

muscle mass: 0.1% 

Personal memory locat.:  12 positions 
Age: 

 

 

10 –  100 years 

Body height: 

 

100 –  250 cm 

Dimensions: 

 

390 mm x 315 mm x 37,5 mm 

Batteries: 

 

1 x 9V (included) 

 
Subject to technical modifications 

 

10. Warranty

 

 
ADE  warrants  for  a  period  of  3  years  from  the date  of  purchase  that  it  will  remedy  any 
defects  due  to  faulty  material  or  workmanship  free  of  charge  by  repair  or  replacement. 
When purchasing, please have the warranty coupon signed and stamped by the dealer. 
When  making  a  guarantee  claim,  please  return  the  weighing  scale  together  with  the 
guarantee card including the reason of complaint to your dealer. 
 

 
 

 

CE-Conformity - This device features radio interference 

 

 

suppression in compliance with valid EC Regulation 2004/108 

 
Note:  The  displayed  value  may  be  adversely  affected  under  extreme  electromagnetic 
influences, e.g. when using a radio unit in the immediate vicinity of the device. Once the 

interference  has  been  rectified,  the  product  can  once  again  be  used  for  its  intended 
purpose. The device may have to be switched on again. 

 

Содержание BA 833

Страница 1: ...eite 4 5 Programmierung Eingabe pers nlicher Daten Seite 4 6 K rperanalyse Seite 5 7 Fehlermeldungen Seite 7 8 Technische Daten Seite 7 9 Garantie Seite 7 Garantieabschn itt 3 Jahre auf die K rperanal...

Страница 2: ...llen ist es daher wichtig immer zur gleichen Zeit zu messen Am einfachsten k nnen Sie dies einhalten wenn Sie immer morgens Stunde nach dem Aufstehen entweder immer vor oder nach dem Gang zur Toilette...

Страница 3: ...n liegt dieser Wert bei ungef hr 55 bedingt durch einen h heren K rperfettanteil Von diesem Gesamtk rperwasser werden ca zwei Drittel in den Zellen gelagert und wird deshalb intrazellul res Wasser gen...

Страница 4: ...Taste und speichern dann mit der ON SET Taste ab Nachdem Sie die Eingabe beendet haben dr cken Sie mit der Hand oder dem Fu auf die Wiegeplattform oder auf die START Taste Im Display erscheint 0 0 kg...

Страница 5: ...use Page 2 3 Commissioning Page 3 4 Weighing function weight measurement only Page 4 5 Programming enter of personal data Page 4 6 Body Analysis Page 5 7 Error Messages Page 7 8 Technical Data Page 7...

Страница 6: ...ame time and under the same conditions every day The easiest way to stick the rule measure always in the morning 15 minutes after you ve got up either before or after you ve gone to the bathroom In sp...

Страница 7: ...ion level means the body fat percentage is slightly higher There is no healthy risk for pregnancy The body analyzer is absolutely safe for the mother and her unborn baby However due to the changes in...

Страница 8: ...completion tap with your hand or foot shortly on the scale or press the START button The display indicates the signal 0 0 kg Afterwards the scale automatically powers off To enter personal data of fur...

Страница 9: ...astadas Puede entregar las pilas inservibles en los puntos p blicos de recogida dispuestos al efecto en su localidad y en todos los establecimientos en que se vendan pilas de ese tipo Indicaci n Encon...

Страница 10: ...s importante medir siempre a la misma hora del d a La forma m s sencilla de atenerse a este principio es realizar la medici n siempre por la ma ana un de hora despu s de levantarse siempre antes o des...

Страница 11: ...del cuerpo Si el cuerpo almacena mucha agua los valores de grasa resultan menores y cuando la proporci n de agua disminuye aumenta algo la de grasa En las mujeres embarazadas la medici n no supone ni...

Страница 12: ...resione la plataforma de pesaje con la mano o con el pie o bien pulse la tecla START En la pantalla se muestra 0 0 kg y despu s la b scula se desconecta autom ticamente a los 8 segundos aprox Si desea...

Страница 13: ...emploi Table des mati res 1 Comment fonctionne la balance d analyse corporelle Page 2 2 Conditions d utilisation Page 2 3 Mise en service Page 3 4 Programmation Enregistrement de donn es personnelles...

Страница 14: ...ors que la r sistance et donc aussi le taux de graisse sont moins lev s Afin d tablir la modification effective de la composition du corps il est donc important de toujours mesurer la m me heure Le mo...

Страница 15: ...nce Il est cependant possible d tablir aussi bien des tendances Chez les femmes les influences p riodiques ont des r percussions sur le r sultat de la mesure car les fluctuations hormonales influent s...

Страница 16: ...e ON SET Apr s avoir termin la saisie appuyez avec la main ou le pied sur la plate forme de pesage ou sur la touche START 0 0 kg appara t l cran ensuite la balance s teint automatiquement apr s 8 seco...

Страница 17: ...4 5 Funzione di pesatura solo rilevamento del peso Pagina 4 6 Analisi corporea Pagina 5 7 Messaggi di guasto Pagina 7 8 Dati tecnici Pagina 7 9 Garanzia Pagina 7 8 1 Certificato di garanzia 3 anni sul...

Страница 18: ...giorno Il modo pi facile per rispettare questa condizione quella di pesarsi al mattino d ora dopo essersi svegliati sempre prima o sempre dopo essere andati di corpo Nonostante l innocuit della corre...

Страница 19: ...presente molta acqua i valori dei grassi saranno inferiori e viceversa Durante la gravidanza non sussiste alcun pericolo per il nascituro A causa del maggiore accumulo di acqua che si registra durant...

Страница 20: ...sone che utilizzano la bilancia ripetere le operazioni descritte sopra 6 Analisi corporea L analisi pu essere effettuata solo a piedi nudi I dati personali devono precedentemente essere stati inseriti...

Страница 21: ...al waar batterijen van de betreffende soort worden verkocht Opmerking Deze tekens vindt u op batterijen Li batterij bevat lithium Al batterij bevat alkali Mn batterij bevat mangaan CR Li AA Al Mn AAA...

Страница 22: ...e tijdstip te meten Dit gaat het gemakkelijkste wanneer u de meting altijd s ochtends een kwartier na het opstaan altijd of voor of na het naar toilet gaan uitvoert Ondanks de minimale stroomsterkte m...

Страница 23: ...inger uit bij weinig vocht iets hoger Bij zwangere vrouwen bestaat geen risico voor de vrucht Wel worden de waarden door de waterophoping tijdens de zwangerschap zozeer vervormd dat meting in feite ge...

Страница 24: ...oets Op het display verschijnt 0 0 kg daarna schakelt de weegschaal na ca 8 seconden automatisch uit Om de gegevens voor andere personen in te stellen herhaalt u bovenstaande stappen 6 Lichaamsanalyse...

Страница 25: ...sobistych parametr w Strona 4 5 Funkcja wa enia wy cznie pomiar masy cia a Strona 4 6 Analiza masy cia a Strona 5 7 Komunikaty o b dach Strona 7 8 Dane techniczne Strona 7 9 Gwarancja Strona 7 8 1 Kup...

Страница 26: ...wa na wadze rano kwadrans po przebudzeniu przed lub po wizycie w toalecie Mimo e waga wysy a podczas pomiaru impuls elektryczny o minimalnym nat eniu nie powinny z niej korzysta osoby z wszczepionym r...

Страница 27: ...lne wydatnie oddzia uj na gospodark wodn organizmu Je li w organi mie znajduj si du e ilo ci wody waga wskazuje ni sz zawarto tkanki t uszczowej natomiast gdy zawarto wody jest wysoka nieco wy sz W pr...

Страница 28: ...w nale y nacisn d oni lub stop na platformie wa cej lub nacisn przycisk START Na wy wietlaczu pojawi si 0 0 kg po czym po up ywie 8 sekund waga wy czy si automatycznie Aby wprowadzi parametry innych o...

Отзывы: