PACKAGE CONTENTS 

Tor V alarm transmitter in a plastic encasement 

 

This user manual  

 

Commissioning instructions (47IN0039) 

 

Installation manual – Removal detector (47IN0051) 

 

Tor V (alarm transmitter) 

 

Removal detector 

 

Internal antenna 

 

Ethernet cable (shielded) 

 

SIM card 

 

Sticker to mount on the fire alarm (EN 54-21:2006) 

 

Labels to mark the connections and indicators on the alarm transmitter 

 

Screws and plugs for installation 

 

External antenna for 4G (GPRS/EDGE/4G) 

 

Option: AC/DC adapter 230V/24V 

3

 

CONDITIONS 

3.1

 

Fire alarm installation (EN 54-21:2006)

 

 

The service profile of the alarm transmitter is to meet the requirements set forth in 
SBF 110:8 (EN 54-21:2006). 

 

The alarm transmitter is to be mounted and connected so that all requirements in SBF 
110:8 (EN 54-21:2006) are met. 

 

The pin inputs and relays are connected to meet the requirements set forth in SBF 
110:8 (EN 54-21:2006). Use inputs normally closed or with a resistor to detect failure. 

 

The alarm transmitter is to be mounted and voltage supplied from the control panel.  

 

Access to voltage supply from the control panel, with 2A fuses.  

 

Externally mounted antenna with satisfactory signal strength for mobile data 
communication. 

 

Marking the outside of the alarm transmitter’s encasement with the included sticker. 

 

Follow the instructions in the following sections: 4.1, 6.1, 6.5 and 7 

3.2

 

Alarm installation (EN 50136/SSF 114) 

For security class 2, the following apply: 

 

Tor V in a plastic encasement without a battery backup but with a mounted removal 
detector. 

 

The service profile of the alarm transmitter is to meet the requirements set forth in 
SSF 114:2/EN 50136. 

 

The pin inputs and relays are connected to meet the requirements set forth in SSF 
114:2/EN 50136. Use inputs normally closed or with a resistor to detect failure. 

 

The alarm transmitter is to be mounted and connected so that all requirements set 
forth in SSF 114:2/EN 50136 are met. 

 

Access to voltage supply of +12V to +30V with battery backup, with 2A fuses for 12V. 

 

Follow the instructions in the following section: 6.2 

 

Содержание Tor V

Страница 1: ...Installation manual Tor V PDK 11606 version 6 0 May 28 2019 Tor V Alarm transmitter Installation manual...

Страница 2: ...6 6 Ethernet connection broadband 12 6 6 1 Firewall configuration 12 6 7 Wireless connection 12 6 8 Reading the signal strength 12 6 9 Serial ports 13 6 9 1 Example of a cable for connecting the contr...

Страница 3: ...EN 54 21 2011 EN 54 21 2006 EN 50130 5 2011 EN 50130 4 2011 A1 2014 Alarm transmission and fault warning routing equipment for intruder and fire alarm systems installed in buildings Notified body App...

Страница 4: ...ess connection and the installation is to follow specific instructions for the installation of fire alarms See section 3 1 for all conditions For the alarm transmitter to meet the requirements of SSF...

Страница 5: ...r with a resistor to detect failure The alarm transmitter is to be mounted and voltage supplied from the control panel Access to voltage supply from the control panel with 2A fuses Externally mounted...

Страница 6: ...llation EN 54 21 2006 For a fire alarm installation it s easiest to mount the alarm transmitter inside the control panel This is so that the installation complies with EN 54 21 2006 Attach the include...

Страница 7: ...satisfactory radio coverage See the signal strength using a computer see the appendix or LEDs during installation see 6 8 Satisfactory signal strength is between 14 and 32 Relieve the various cables t...

Страница 8: ...AddSecure Tor V PDK 11606 8 5 CONNECTIONS Figure 1 Plastic encasement side 1 Figure 2 Plastic encasement side 2 Figure 3 Plastic encasement from above...

Страница 9: ...tput Connect the control panel s output for error indication to optional alarm input Balance the output from the control panel with 4 7k 6 2 Alarm installation EN 50136 SSF 114 To meet security grade...

Страница 10: ...er are analogue balanced at 4 7k the resistor is to be mounted as such This connection can keep the control panel galvanically isolated from the alarm transmitter Figure 6 Voltage of 5V to 12V with li...

Страница 11: ...n and pin 9 common to the alarm panel at the appropriate input so that the alarm panel can detect a short circuit open circuit on the connection Status Ok The relay is closed when the alarm transmitte...

Страница 12: ...28 corresponds to 85 117 163 240 28 corresponds to 85 117 160 240 85 117 160 255 85 117 163 240 85 117 163 255 6 7 Wireless connection The alarm transmitter is equipped with an FME male connector for...

Страница 13: ...necting the control panel A 5 meter ready to go is available as an option and can be ordered Article number 80 321 329 6 9 2 Example of a null modem cable for connecting a PC S2 NAME FUNCTION 1 Tx Tra...

Страница 14: ...al that the SIA or Contact ID protocol uses In this way the alarm transmitter receives and acknowledges messages that the control panel sends through its telephone connection After the transmission fr...

Страница 15: ...ckup 9 2 The A diode is blinking and the C diode is turned off The alarm transmitter does not have contact with the mobile network Check the cables and the antenna The cables must not be spliced or pi...

Страница 16: ...nnector Modular RJ12 ESPA support ESPA 4 4 4 Maximum cable length 15 meters ALARM INPUTS Inputs 8 analogue or digital inputs with internal pull up Maximum cable length 30 meters Voltage across open in...

Страница 17: ...down 6 The LEDs display as normal no matter whether the interference protection is affected Table 1 signal strength Indicator Status Signal strength Satisfactory LED color LED A On 25 Yes Green LED B...

Страница 18: ...tions Here are only the details necessary to measure signal strength in your web browser 1 Configure your computer for DHCP you automatically get an IP address between 172 20 20 20 and 172 20 20 250 2...

Страница 19: ...le You are notified by the alarm center or through for example AddView that there is a disturbance causing your service to not work The alarm center will ask you to trigger a test alarm The alarm will...

Страница 20: ...AddSecure Tor V PDK 11606 20 STOCKHOLM OSLO LONDON G TEBORG MALM ESPOO ZUG WWW ADDSECURE COM...

Отзывы: