Alarm format SMS
Selecting SMS format for all pins or ticking this box for a specific pin will mean
that on input “Set” (open circuit) and input “Restore” (closed circuit), the
terminal will send the configured SMS text for the set or restore message to the
configured phone number.
6.13.2.1
Phone number
This option lets you enter the phone number to which the SMS message will be sent
.
6.13.2.2
Set msg and Restore msg
Enter the Set and Restore text messages to be sent. No message is sent for an entry that is blank.
Alarm format SIA
On input “Set” (open circuit) and input “Restore” (closed circuit), the terminal
will send SIA alarm protocol messages for that input.
6.13.3.1
Set msg and Restore msg
Here you can input the “Set” and “Restore” messages in the correct format as defined in SIA format protocol
SIA DC-03-1990.01(R2003.10). The default "Set" and "Restore" event codes are in the table below.
These defaults can be changed and text descriptions to be sent with the SIA alarm code (under SIA level 3
alarm protocols) can be added. If you exceed the maximum number of characters for the combined set and
restore messages supported by the terminal, a warning will be shown.
Text descriptions can be added by adding ^ before and after the text. For example, to add the text "Fire" to
the message SIA code "NFA01", input "NFA01^FIRE^" into the touchscreen.
Pin
no.
Set message
SIA code
Restore
message
SIA code
SIA event description
1
NFA01
NFR01
Fire alarm zone 1
2
NPA02
NPR02
Panic alarm zone 2
3
NBA03
NBR03
Burglary alarm zone 3
4
NOP04
NCL04
Open/Close zone 4
5
NIA05
NIR05
Equipment fault zone 5
6
NBB06
NBU06
Burglary bypass zone 6
7
NBV07
NBR07
Burglary verified zone 7
8
NTA08
NTR08
Tamper alarm zone 8
9
NAT09
NAR09
AC Power trouble zone 9
10
NFT10
NFJ10
Fire trouble zone 10
11
NQA11
NQR11
Emergency alarm zone 11
12
NYT12
NYR12
System battery trouble zone 12
13
NMA13
NMR13
Medical alarm zone 13
14
NUA14
NUR14
Untyped alarm zone 14
15
NUA15
NUR15
Untyped alarm zone 15
16
NUA16
NUR16
Untyped alarm zone 16