background image

15

CONTENTS

INTR

ODUCTION

INST

ALLA

TION

OPERA

TION

FUR

THER

 

INFORMA

TION

RADIO FREQUENCY ENERGY

A Category 6a (or better) twisted pair cable must be used to connect the units in order 
to maintain compliance with radio frequency energy emission regulations and ensure a 
suitably high level of immunity to electromagnetic disturbances.
All other interface cables used with this equipment must be shielded in order to maintain 
compliance with radio frequency energy emission regulations and ensure a suitably high 
level of immunity to electromagnetic disturbances.

European EMC directive 2004/108/EC

This equipment has been tested and found to comply with the limits for a class A 

computing device in accordance with the specifications in the European standard 

EN55022. These limits are designed to provide reasonable protection against harmful 
interference. This equipment generates, uses and can radiate radio frequency energy 
and if not installed and used in accordance with the instructions may cause harmful 
interference to radio or television reception. However, there is no guarantee that 
harmful interference will not occur in a particular installation. If this equipment does 
cause interference to radio or television reception, which can be determined by turning 
the equipment on and off, the user is encouraged to correct the interference with one 
or more of the following measures: (a) Reorient or relocate the receiving antenna. 
(b) Increase the separation between the equipment and the receiver. (c) Connect 
the equipment to an outlet on a circuit different from that to which the receiver is 
connected. (d) Consult the supplier or an experienced radio/TV technician for help. 

FCC Compliance Statement (United States)

This equipment generates, uses and can radiate radio frequency energy and if not 
installed and used properly, that is, in strict accordance with the manufacturer’s 
instructions, may cause interference to radio communication. It has been tested and 
found to comply with the limits for a class A computing device in accordance with 

the specifications in Subpart J of part 15 of FCC rules, which are designed to provide 

reasonable protection against such interference when the equipment is operated in a 
commercial environment. Operation of this equipment in a residential area may cause 
interference, in which case the user at his own expense will be required to take whatever 

measures may be necessary to correct the interference. Changes or modifications not 

expressly approved by the manufacturer could void the user’s authority to operate the 
equipment.

Canadian Department of Communications RFI statement

This equipment does not exceed the class A limits for radio noise emissions from digital 
apparatus set out in the radio interference regulations of the Canadian Department of 
Communications.

Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites 

applicables aux appareils numériques de la classe A prescrites dans le règlement sur le 

brouillage radioélectriques publié par le ministère des Communications du Canada.

WARRANTY

Adder Technology Ltd warrants that this product shall be free from defects in 
workmanship and materials for a period of two years from the date of original purchase. 
If the product should fail to operate correctly in normal use during the warranty period, 
Adder will replace or repair it free of charge. No liability can be accepted for damage due 
to misuse or circumstances outside Adder’s control. Also Adder will not be responsible 
for any loss, damage or injury arising directly or indirectly from the use of this product. 
Adder’s total liability under the terms of this warranty shall in all circumstances be 
limited to the replacement value of this product.

If any difficulty is experienced in the installation or use of this product that you are 

unable to resolve, please contact your supplier.

SAFETY INFORMATION

• 

For use in dry, oil free indoor environments only.

• 

Do not use to link between buildings.

• 

Ensure that the twisted pair interconnect cable is installed in compliance with all 
applicable wiring regulations. 

• 

Do not connect the CATx link interface (RJ45 style connector) to any other 
equipment, particularly network or telecommunications equipment.

• 

Warning – the power adapter contains live parts.

• 

No user serviceable parts are contained within the power adapter - do not dismantle.

• 

Plug the power adapter into an earthed socket outlet close to the unit that it is 
powering.

• 

Replace the power adapter with a manufacturer approved type only. 

• 

Do not use the power adapter if the power adapter case becomes damaged, cracked 
or broken or if you suspect that it is not operating properly.

• 

If you use a power extension cord with the units, make sure the total ampere rating of 
the devices plugged into the extension cord do not exceed the cord’s ampere rating. 
Also, make sure that the total ampere rating of all the devices plugged into the wall 
outlet does not exceed the wall outlet’s ampere rating.

• 

The units and power supplies can get warm in operation – do not situate them in an 
enclosed space without any ventilation. 

• 

The units do not provide ground isolation and should not be used for any applications 
that require ground isolation or galvanic isolation.

Содержание X-DVIPRO-DL

Страница 1: ...AdderLink X DVIPRO DL User Guide Experts in Connectivity Solutions KVM Extender Solutions...

Страница 2: ...rack 5 Connections at the local module 6 Power connection 7 Connections at the remote module 8 Power connection 9 Operation General use 10 Video display EDID information 10 HDMI 1 3a operation 10 Pow...

Страница 3: ...DL extender modules have been designed to be quick to install and totally transparent in operation Cable type and distance rules Cable screening is paramount The best cable screening specifications fo...

Страница 4: ...cable 2m type A to B Part number VSC24 Dual link video cable DVI D to DVI D Part number VSCD3V 2 x 12 5W power adapters and country specific power cords Information wallet containing Four self adhesiv...

Страница 5: ...PERATION FURTHER INFORMATION OPTIONAL EXTRAS Rack mount chassis Part number X RMK CHASSIS Rack mount kit for X DVIPRO DL Part number X RMK FASCIA HDMI to DVI D video cable Part number VSCD11 50 meter...

Страница 6: ...ly the supplied self adhesive rubber feet to the underside of the module Rack mount 1 Place the rack securing plate available as a separate kit onto the front of the module and secure it with the two...

Страница 7: ...USB cables longer than 3 meters to connect the local module to the computer 4 Optionally use the supplied audio cable to link the audio port to the stereo audio output of the computer To audio port CA...

Страница 8: ...the supplied power cord into the corresponding socket of the power adapter Output lead from the power adapter 3 Wait before connecting the other end of the power cord to a nearby mains outlet until th...

Страница 9: ...A maximum each If more power for USB devices is required please use a powered USB hub 4 Optionally connect a set of stereo speakers to the module To speakers 5 Connect the link cable see page 2 for ca...

Страница 10: ...he supplied power cord into the corresponding socket of the power adapter 3 After all connections are made power up the display screen and connect the other end of this power cord to a nearby mains ou...

Страница 11: ...is then made available to the computer s video adapter when required HDMI 1 3a operation Using optional HDMI to DVI converter cables Adder part number VSCD11 the AdderLink X DVIPRO DL can support HDMI...

Страница 12: ...l module directly to the computer and check for a correct image REMOTE If the yellow indicator is flashing then the video feed via the link cable is not valid If the link cable is long try using a sho...

Страница 13: ...ions Online solutions and updates www adder com support Check the Support section of the adder com website for the latest solutions and firmware updates Adder Forum forum adder com Use our forum to ac...

Страница 14: ...2 AWG should be used Solid Stranded The teeth of the insulation displacement connectors are designed to straddle and hug the sides of the solid center conductor of the cable The teeth of the insulatio...

Страница 15: ...P RJ45 connectors CU 7702 4P flex Flexible data cable S FTP Cat 7 AWG26 1 Inner conductor AWG26 bare copper wire stranded 2 Wire 0 99 mm 3 Screen pair Alu PETP foil 4 Screen Tinned braided copper 5 Sh...

Страница 16: ...d the user s authority to operate the equipment Canadian Department of Communications RFI statement This equipment does not exceed the class A limits for radio noise emissions from digital apparatus s...

Страница 17: ...RATION FURTHER INFORMATION www ctxd com Documentation by 2014 Adder Technology Limited All trademarks are acknowledged Part No MAN X DVIPRO DL ADDER Release 1 0a Web www adder com Contact www adder co...

Отзывы: