ADDER AdderLink Infinity 1002 Скачать руководство пользователя страница 3

INST

ALLA

TION

2

CONFIGURA

TION

OPERA

TION

FUR

THER

INFORMA

TION

INDEX

Introduction

WELCOME

Thank you for choosing the AdderLink Infinity (aka ALIF) family of high capacity digital 
extenders/switches. By encoding high quality DVI video, digital audio and USB data into 
Internet Protocol (IP) messages, ALIF units offer flexible ways to link peripherals and 
systems via standard networks.
This guide covers the ALIF 1002 and ALIF dual (2002T, 2000R and 2020) models, all 
of which can transfer single link DVI video, digital audio and USB signals across your 
network. The ALIF dual 2002T, 2000R and 2020 models can also handle a second single 
link DVI video stream; while 2002T and 2000R models can additionally transfer one very 
high resolution Dual Link DVI video connection (

or

 two single link DVI streams).  The 

capabilities are summarized below:   

Model 

ALIF 

ALIF dual 

ALIF dual 

ALIF dual VNC 

 

1002 T/R 

2020 T/R 

2002T / 2000R 

2112T

Primary video

 

Single link 

Single link 

Dual link 

Dual link

Secondary video

 

Single link 

Single link 

Single link

VNC support

 x  x 

Yes

Note: The ALIF dual VNC (2112T) unit is covered by a separate user guide.

ALIF 1002 and all ALIF dual variants both provide a choice of link connections. Each 

supports both copper-based Gigabit Ethernet cabling as well as Fiber Channel over 
Ethernet (FCoE). These can be used in parallel to provide up to 2 Gigabit connection 
speeds with the added benefit of link redundancy that can maintain operation in the 
event of a failed connection. Additionally, all ALIF dual models also benefit from a 

Management port

 that makes configuration even more straightforward.    

ALIF units promote sharing; you can arrange for a limitless number of screens and 
speakers, distributed anywhere across the network, to receive video and audio. You can 

also switch between any number of transmitter units using a single screen, keyboard and 
mouse in order to monitor a potentially vast collection of remote systems.

Mixing ALIF dual units with the original ALIF 1000 series

ALIF dual (2000 series) are complimentary to the original ALIF (1000 series) models 
which do not support dual DVI channels or fiber optic linking. It is possible to mix ALIF 
and ALIF dual transmitters and receivers on a network. However, whenever the two 
types are cross connected, the extra abilities of the ALIF dual units will be temporarily 
disabled.
The newer ALIF 1002 models now include the ability for a second Gigabit Ethernet or 

Fiber Channel over Ethernet connection as per the ALIF dual models. ALIF 1002 units 
can be mixed with all ALIF dual units without any loss of functionality.

One-to-one configuration

The simplest configuration links one RX unit to a single TX unit, either by a direct link or over much 
greater distances via a high speed network. In both cases, Gigabit cable linking and/or fiber can be used. 
When both are deployed, connection speeds of up to 2 Gigabits are possible. 

ALIF and A.I.M.

Where multiple ALIF units are used on a network, we have developed the AdderLink 
Infinity Management (A.I.M.) server to allow comprehensive and secure central 
control of all transmitters, receivers and users.
When using an A.I.M. server to configure ALIF 
units, it is vital that all ALIF units that you wish 

to locate and control are set to their factory 
default settings. Otherwise they will not be 
located by the A.I.M. server. If necessary, 
perform a 

factory reset

 on each ALIF unit.

Please also see 

Appendix C - Tips for success when networking ALIF units

     

www.adder.com

AdderLink

ADM

ADM

USR

USR

UNC

UNC

ETH1

ETH1

ETH2

ETH2

PWR

PWR

MANAGEMENT SERVER

One-to-many configuration

Using multicast techniques, an unlimited number 
of receivers* can receive video and audio data 

streams from a single TX unit.   

* A maximum of thirteen concurrent USB inputs (via 
multiple RX units) are permitted to a single TX unit.

Содержание AdderLink Infinity 1002

Страница 1: ...AdderLink Infinity and Infinity dual User Guide Experts in Connectivity Solutions KVM Extension Solutions 1002 2000 2002 2020...

Страница 2: ...devices 17 RX AUX serial port 18 RX power in 18 Configuration Initial configuration 19 Manual factory reset 19 AdderLink Infinity browser based configuration utility 20 Performing an upgrade 21 Optio...

Страница 3: ...r of transmitter units using a single screen keyboard and mouse in order to monitor a potentially vast collection of remote systems Mixing ALIF dual units with the original ALIF 1000 series ALIF dual...

Страница 4: ...dithering is an issue for KVM extenders such as ALIF because it makes the image appear to be changing all the time even when it is static thus creating much more network data than can be carried by a...

Страница 5: ...dderLink Infinity units at or above v3 3 you will then be prompted to upgrade the AdderLink Infinity units ALIF1002 units are only available with firmware starting at v3 3 and cannot be downgraded so...

Страница 6: ...USB On when the USB link with the connected PC is active DVI On when a video input signal from the PC is detected PWR Power indicator ADDERLINK INFINITY 1002 UNIT FEATURES The ALIF 1002 units are hous...

Страница 7: ...icator ADDERLINK INFINITY DUAL UNIT FEATURES The ALIF dual units are housed within durable metallic enclosures with most connectors situated at the rear panel the Ethernet ports are situated on the fr...

Страница 8: ...1002 Audio cable 2m 3 5mm stereo jacks ALIF transmitter 1002T package Power adapter 20W and country specific power cord ALIF receiver 1002R package Information wallet containing Four self adhesive ru...

Страница 9: ...IF dual transmitter 2002T 2020T package Power adapter 20W and country specific power cord ALIF dual receiver 2000R 2020R package Information wallet containing Four self adhesive rubber feet Quick star...

Страница 10: ...B 9F 9F NULL MODEM USB cable 2m type A to B Part number VSC24 Single mode fiber SFP module Part number SFP SM LC Multi mode fiber SFP module Part number SFP MM LC Please refer to the table in Appendix...

Страница 11: ...while the ALIF RX unit is attached to your peripherals Click a connection to see details IMPORTANT When using an AdderLink Infinity Management box to configure ALIF units it is vital that all ALIF uni...

Страница 12: ...ost computer To make a video link 1 Wherever possible ensure that power is disconnected from the ALIF and the host computer 2 Connect your digital video link cable s to the DVI D socket s on the TX un...

Страница 13: ...audio link cable between the IN socket on the TX unit rear panel and the speaker output socket of the host computer AUX DVI D 1 OUT IN Speaker link from host computer Microphone link to host computer...

Страница 14: ...e power adapter unit INDOOR USE ONLY OPT 1 5V 2 5A 1 2 Connect the IEC connector of the supplied country specific power cord to the socket of the power adapter 3 Connect the power cord to a nearby mai...

Страница 15: ...ectors to lock them into place Transmit and receive fiber links Cable and fiber details For direct links over Ethernet cable the length of cable should not exceed 100 metres 328 feet Network cables us...

Страница 16: ...uration utility using a consistent IP address thus negating the need to know the main port addresses of each ALIF dual unit in advance To connect a computer to access the configuration utility 1 Conne...

Страница 17: ...2 ALIF dual only If required connect the lead from the second video display to the DVI D 2 socket on the RX unit rear panel To connect video displays 1 Connect the lead from the primary video display...

Страница 18: ...onnect the lead from the device to any of the four USB sockets on the rear panel of the ALIF unit LINE I USER CONSOLE MIC I Connection from USB device Supported USB Devices The transmitter unit uses T...

Страница 19: ...r unit INDOOR USE ONLY OPT 1 5V 2 5A 1 2 Connect the IEC connector of the supplied country specific power cord to the socket of the power adapter 3 Connect the power cord to a nearby main supply socke...

Страница 20: ...ansmitters and receivers from a single application IMPORTANT When using A I M to configure ALIF units it is vital that all units that you wish to locate and control are set to their factory default se...

Страница 21: ...rted if you do use one 2 Connect the other end of the link cable directly to the network port of your computer To access the browser based configuration utility 1 Temporarily connect the ALIF unit and...

Страница 22: ...or the Backup 5 Click the Upgrade Now button A progress bar will be displayed however if your screen is connected to the unit being upgraded then video may be interrupted and the indicators on the fro...

Страница 23: ...k unhindered FRONT PANEL INDICATORS The six front panel indicators on each unit provide a useful guide to operation Operation Indicators These six indicators clearly show the key aspects of operation...

Страница 24: ...ting options Safety information Warranty Radio frequency energy statements GETTING ASSISTANCE If you are still experiencing problems after checking the information contained within this guide then we...

Страница 25: ...iguration pages This section covers the browser based configuration utility for the AdderLink Infinity TX transmitter unit The TX utility has ten pages titled as follows System Configuration System Me...

Страница 26: ...vate range you are recommended to change this to 255 255 255 0 The default gateway address is 169 254 1 1 Note Before theTeaming port can be used for connection via a network you need to ensure that t...

Страница 27: ...DC When the Use Default DDC option is unticked AdderLink Infinity will use the EDID that is reported by the monitor connected to the receiver unit However if you tick the Use Default DDC option you ca...

Страница 28: ...r will always find the device This option allows you reserve up to 8 ports for certain devices At the RX unit the devices are assigned to the reserved ports If a port reservation is to be applied then...

Страница 29: ...ess of a suitable server here also To get here 1 Connect your computer to a port on the front panel 2 Run a web browser and enter the IP address of the Management ALIF dual only or System port used ht...

Страница 30: ...ton after ticking the above checkbox to plot the chosen statistics on a pop up graph Upgrade Use this page to upgrade the main or backup firmware image on the unit Please see the section Performing an...

Страница 31: ...requested by Adder Technical Support To get here 1 Connect your computer to a port on the front panel 2 Run a web browser and enter the IP address of the Management ALIF dual only or System port used...

Страница 32: ...unit configuration pages This section covers the browser based configuration utility for the AdderLink Infinity RX receiver unit The RX utility has nine pages titled as follows System Configuration St...

Страница 33: ...1 1 Note Before theTeaming port can be used for connection via a network you need to ensure that the System port has been configured away from its zero config IP address Enable options These checkbox...

Страница 34: ...units connected in addition to the System ports if one of the links should fail for any reason there will be a short delay for a few video frames and possibly some on screen corruption as all the dat...

Страница 35: ...s you map the four USB connectors on the receiver to a specific USB port that has been reserved on the transmitter It is useful if you have a specific device e g a touch screen that must allows be rep...

Страница 36: ...urity so that the configuration pages are only accessible to the admin user with a password Change confirm password These options allow you to change the admin password for the system To get here 1 Co...

Страница 37: ...he address is unknown perform a manual factory reset 3 Click either the AIM Manager or System Messages links as appropriate Enable system messages Tick to allow the creation of status and error messag...

Страница 38: ...troubleshooting and optimization purposes When you enable this option you will first be presented with a pop up from which you can choose which aspects you would like to graph Data throughput various...

Страница 39: ...requested by Adder Technical Support To get here 1 Connect your computer to a port on the front panel 2 Run a web browser and enter the IP address of the Management ALIF dual only or System port used...

Страница 40: ...ghout a single subnet You also need a Layer 3 switch Ensure that it can operate efficiently as an IGMP Querier Creating an efficient network layout Network layout is vital The use of IGMP snooping als...

Страница 41: ...1152 ensure that Jumbo Frames are enabled on all switches Choose an appropriate forwarding mode on all switches Use Cut through if available otherwise Store and forward Optimize the settings on the AL...

Страница 42: ...are output by an ALIF unit but the network switches have not been configured to use jumbo frames the switches will attempt to break the large packets down into standard packets This process introduces...

Страница 43: ...02R and 2020R units cannot process Dual Link DVI as they are Single Link devices Ensure that the ALIF transmitter is set to supply a Single Link EDID to the graphics card When the video source is chan...

Страница 44: ...l hosts report which multicast streams they wish to receive The Querier device and all snooping Layer 2 switches then update their lists accordingly the lists are also updated when Join Group and Leav...

Страница 45: ...ans that cut through switches cannot discard faulty packets themselves However on receipt of the marked packet a host will carry out the discard process Fragment free is a hybrid of the above two meth...

Страница 46: ...that is assigned to every networking device at manufacture Deciphering recipients at this level is more straightforward than at Layer 3 where the address of the recipient is represented by a logical I...

Страница 47: ...Mount kits Rack mount single or dual units per 1U slot VESA monitor wall mount chassis Power to adapter 100 240VAC 50 60Hz 0 8A Power to unit 5VDC 20W Operating temp 0 C to 40 C 32 F to 104 F Approval...

Страница 48: ...dder part number for SFP module Bar color Conn type Normal Applications Military Applications Suggested Print Nomenclature OM1 62 5 125 Multimode TIA 492AAAA Orange Slate 62 5 125 220m SFP MM LC Black...

Страница 49: ...where air cannot circulate to cool the equipment When mounting units within a rack chassis allow a 1 3 rd U space 1 5cm between rows of devices Do not operate the equipment in ambient temperatures exc...

Страница 50: ...The ALIF units and their power supplies generate heat when in operation and will become warm to the touch Do not place them in locations where air cannot circulate to cool the equipment When mounting...

Страница 51: ...ket mount This optional kit comprises a bracket that allows a single AdderLink Infinity module to be mounted onto the rear of a video display The kit includes the bracket plus eight screws The video d...

Страница 52: ...y is experienced in the installation or use of this product that you are unable to resolve please contact your supplier SAFETY INFORMATION For use in dry oil free indoor environments only Warning live...

Страница 53: ...crease the separation between the equipment and the receiver c Connect the equipment to an outlet on a circuit different from that to which the receiver is connected d Consult the supplier or an exper...

Страница 54: ...N FURTHER INFORMATION INDEX www ctxd com Documentation by 2015 Adder Technology Limited All trademarks are acknowledged Part No MAN ALIF2000 ADDER Release 3 4 Web www adder com Contact www adder com c...

Страница 55: ...5 6 Front panel indicators 22 G Gigabit Ethernet 14 I IGMP 43 fast leave 43 querier 43 snooping 43 Indicators 5 6 22 Initial configuration 19 J Jumbo frames packets 43 L Layers 2 and 3 45 Link cable l...

Отзывы: