ADCP-61-819
•
Issue 1
•
July 2000
Page 4
© 2000, ADC Telecommunications, Inc.
Figure 4
shows the rear panel of the Redundant Amplifier Switch. The parts are identified by
letter and include a brief description.
B
C
D
E
F
G
H
A
15028-A
Figure 4. Rear Panel of the Redundant Amplifier Switch
LETTER
NAME
DESCRIPTION
A
Frame Ground Screw
Grounds the unit to the equipment rack/frame
B
Setup Button
Calibrates the unit
C
BNC/F-Type Connectors
Connects the unit to network equipment
D
RS-485 Receptacles
Input and output for personal computer (with S
WATCH
TM
switch monitoring software) interface cables
E
Terminal Block
Alarm and
–
48V battery power DC power connections
F
24V VDC Power
Provides 24V VDC power in for power supplies 1 and 2
(left) and 24V switched power out for Amps A and B (right)
G
AC Power Out Receptacles
120 VAC outputs for powering external equipment
H
AC Power Input Receptacle
Connects the unit to 120 VAC power supply