ADCP-61-819 • Issue 1 • July 2000
Page 21
© 2000, ADC Telecommunications, Inc.
Send Email on Warning
– Select this check box to be notified if a warning occurs.
Minimum Time Between Messages
– Enter the amount of time (0 to 240 minutes)
between notifications.
Figure 20. “Reporting” Tab
Mail Server
– Enter your e-mail server information in this box.
To
– Enter the destination e-mail address in this box.
From
– Enter the source e-mail address in this box.
Subject
– Enter a default e-mail subject in this box.
Message
– Enter the text of the message in this box. The message may contain “tokens”
that will be converted based on the event being reported. Tokens consist of the percent
character, followed by a zero or more decimal digits, followed by a character listed
below. The digits determine the maximum width of the substituted result, taking the
right most characters. A width of four will convert “ABC123” to “C123”. With no digits,
the result will have no truncated characters.
%e
Event Name
%s
Event severity, 0= normal, 1=warning, 2=fail
%d
Date of event
%t
Time of event
%u
Unit serial number, if applicable
%p
Port number, if applicable, 1 or 2
%n
Port name, if applicable
%%
The percent character