ADC Telecommunications, Inc.
D
ESCRIPTION
When used with the PG-Flex
Plus
, a typical integrated system configuration is comprised of a FLL-814 in the CO, one
FRL-842 and three RT Channel Units at the RT (
). Up to eight integrated systems can be supported in a
PCS-719 Central Office Terminal (COT) Shelf. A management unit, common to all systems installed in the COT
Shelf, provides an interface for alarm relays and testing of subscriber circuits. A multiplexer card takes the DS0s
from the system and converts them to D4, ESF, or TR-08 DS1 signals at DSX-1 levels.
When used with the PG-Flex, a typical universal system is comprised of one line unit and three channel units at both
the COT and RT (
). The FCS-719 COT shelf supports up to four systems. The channel unit card in the COT
must be the same type of slot specific card (POTS or ISDN) as the channel unit installed at the RT. A PG-Flex FPI-
829 Pair Gain Test Controller (PGTC) Interface Unit (common to all systems installed in the shelf) provides an
interface for maintenance, alarm relays, and metallic access to the remote subscriber lines.
The remote end of either system type is housed in a RT Enclosure. RT Enclosures are designed for indoor and
outdoor applications and are provided with a diverse selection of mounting options. These RT Enclosures support
one or more systems that include one FRL-842 and up to three RT Channel Units for each system.
Figure 1. Typical Integrated Configuration
Figure 2. Typical Universal Configuration
PMX-744
PLL-735
PLL-735
PG-Plus
COT Shelf
Class 5
Switch
PLL-735
HDSL
(1 pair per NID)
HDSL
(1 pair per NID)
POTS
&
ISDN
PG-Flex
RT
Doubler
PG-Plus
NID
PG-Plus
NID
POTS
&
ISDN
POTS
&
ISDN
PMX-744
HDSL
(2 pair per RT)
DSX1 (8)
MLT
TBCU
Test
Tip & Ring
VT-100 Terminal
PMU-712
FLL-814
FRC-753
FRC-753
FRC-756
FR
L-842
HDSL
(2 pair per RT)
Power
(2 pair per Doubler)
(optional)
Class 5
Switch
PG-Flex
COT Shelf
Class 5
Switch
Doubler
Doubler
POTS
&
ISDN
HDSL
(2 pair per RT)
HDSL
(2 pair per RT)
MLT
PGTC
VT-100 Terminal
FPI-829
HDSL
(2 pair per RT)
HDSL
(2 pair per RT)
Power
(2 pair per Doubler)
(optional)
Power
(2 pair per Doubler)
(optional)
Central
Office
Switch
FLC-706
FLC-706
FLC-703
FLC-703
FLC-703
FLC-703
F
LL-
81
2
FL
L-
8
12
PG-Flex
RT
FRC-753
FRC-753
FRC-756
FRL
-8
4
2
PG-Flex
RT
POTS
&
ISDN
FRC-753
FRC-753
FRC-756
FR
L
-84
2
24 Tip-Ring
Cross-Connects
per System
24 Tip-Ring
Cross-Connects
per System
Office
Clock
28 Conductor
PGTC Cable
Composite Clocks
(2 shielded pairs)
(Not required
for POTS)
Содержание PG-Flex FRL-842
Страница 2: ......
Страница 8: ...SCP FRL842 013 01H April 22 2003 vi ADC Telecommunications Inc...
Страница 10: ...SCP FRL842 013 01H April 22 2003 viii ADC Telecommunications Inc...
Страница 12: ...SCP FRL842 013 01H April 22 2003 x ADC Telecommunications Inc...
Страница 151: ......