background image

Chapter 2: Installation

December 20, 2004

2-12

LTPH-UM-1261-01

Optional Fan Alarm Procedure

Figure 2-3. Alarms Wire-wrap Field (TB2)

Note:

 The FAN terminals wire-wrap field provides access to the Normally Open (NO), Form A fan relay 

contact located on the HMU-319 management unit. A temperature monitor activates this fan relay when the 
shelf temperature exceeds 45°C (±1°C) and deactivates the relay when the temperature drops below 35°C 
(±1°C). If the temperature exceeds 77°C (±1°C) a critical alarm is also generated. The critical alarm resets 
when the temperature drops below 40°C (±1°C).

Step

Action

1

Connect the optional fan inputs to the Alarms wire-wrap field pins 25 and 26 (see 

Figure 2-3

).

NC

C NO

CR IT

AUD

CRIT

VIS

MAJ

AUD

MAJ

VIS

MIN

AUD

MIN

VIS

SYS

ID

ACO

1

2

3

4

5

6

7

8

9

10 11

12

13

14

15

16

17 18

19 20

21

22

0

6

-1

2

6

1

R

1

ALARMS

23 24

GND

E XT

TEMP

25

26

NO COM
    FAN

Содержание HiGain HMS-318 List 3

Страница 1: ...HiGain Managed Shelf 19 inch 3190 Mechanic 22 Slot Managed CO Shelf HMS 318 List 3 User Manual Document Number LTPH UM 1261 01 Product Catalog HMS 318 List 3 CLEI T1MF2S04RA...

Страница 2: ...mark Other product names mentioned in this practice are used for identification purposes only and may be trademarks or regis tered trademarks of their respective companies Disclaimer of Liability Info...

Страница 3: ...Ports 1 13 Heat Dissipation Factors 1 13 Air Flow Guidelines 1 15 Chapter 2 Installation 2 1 Before You begin 2 1 Safety Guidelines 2 4 Mounting the HMS 318 List 3 Shelf 2 4 DSX 1 and HDSLx Connectio...

Страница 4: ...Table of Contents December 20 2004 iv LTPH UM 1261 01...

Страница 5: ...re 1 6 HLU Slot Wire wrap Pinouts for HDSL2 Circuits 1 9 Figure 1 7 HLU Slot Wire wrap Pinouts for HDSL4 Circuits 1 10 Figure 1 8 HLU Slot Wire wrap Pinouts for Span Powered xDSL 1 11 Figure 1 9 HMS 3...

Страница 6: ...List of Figures December 20 2004 vi LTPH UM 1261 01...

Страница 7: ...Table 1 4 J27 AUX RS 232 Management Port DTE 1 13 Table 2 1 HMS 318 List 3 Shelf Parts List 2 2 Table A 1 P1 DSX 1 Receive or Span Powered xDSL B IN Tip and Ring A 1 Table A 2 P2 DSX 1 Transmit or Spa...

Страница 8: ...List of Tables December 20 2004 viii LTPH UM 1261 01...

Страница 9: ...tary information for the HMS 318 List 3 Shelf User Manual Copies of these manuals are available online at ADC s web site at www adc com documentationlibrary or you can order copies of these documents...

Страница 10: ...itive to static electricity Appendix D Specifications Provides power requirements physical dimensions recommended operational and storage environments and accessories for the HMS 318 List 3 shelf Appe...

Страница 11: ...before during and after shelf installation If an electrical accident occurs proceed as follows Use caution do not become a victim yourself Turn power off to the telco style rack that the shelf is loca...

Страница 12: ...s circuits Coming in contact with high electrical potential will result in death or severe personal injury IMPORTANT The shelf chassis must be properly grounded to ensure personal and equipment safety...

Страница 13: ...List 3 shelf supports 1 544 Mbps T1 full duplex transmission over two unconditioned non loaded copper loops DSX 1 interfaces at the CO and the remote end with remote provisioning and performance moni...

Страница 14: ...wered xDSL or ADSL pairs per module and is used as an integral part of the LoopStar Wi Fi span powered Access Point AP solution A total of 11 LPS 300C modules can be installed in the UL 60950 complian...

Страница 15: ...d pin assignments see Appendix A Signal and Pin Assignments on page A 1 LoopStar LPS 300C Power Module configuration for Wi Fi Also located on the rear panel for Visual Audible Alarm Contact operation...

Страница 16: ...to and from the DSLAM P2 Amphenol 50 pin Male CO PAIR 2 DS1 xDSL A IN Tip and Ring non powered xDSL signal to and from the DSLAM P3 Amphenol 50 pin Male SPAN PAIR 1 HDSL xDSL A OUT Tip and Ring bi di...

Страница 17: ...nd B Figure 1 3 Input Power Terminal Block TB1 HMS 318 List 3 Shelf Input Power Connections The input power terminal block supports split 48V battery power bussing Slots 1 through 11 on the HMS 318 Li...

Страница 18: ...off can be achieved by pressing the ACO button on the front panel of the Management Unit for example HMU 319 or by connecting the ACO pin 22 on the HMS 318 List 3 shelf Alarms wire wrap field see Figu...

Страница 19: ...cator of the CO alarm system MAJ VIS Major Visible There is a major alarm active on the HMS 318 List 3 shelf Connect this relay to the major alarm visual indicator of the CO alarm system MIN AUD Minor...

Страница 20: ...connectors through the HMS 318 List 3 shelf s rear panel wire wrap pins 0 045 inch square 1 14 mm Straps for cable dressings and a protective Lexan rear cover are provided with each shelf Figure 1 5...

Страница 21: ...m when activated Minor alarm output is normally floating 0 to 60V maximum and a ground 10 ma maximum 5 Vdc for HLU 319 List 2D when activated Notes System Alarm DSX 1 Tip IN DSX 1 Tip 1 OUT DSX 1 Ring...

Страница 22: ...o the LoopStar LPS 300C L1 Power Module Technical Practice catalog number SCP LPS300 010 for installation initialize and power up information ATTENTION To ensure against damage to electronic component...

Страница 23: ...el for xDSL circuits Figure 1 8 HLU Slot Wire wrap Pinouts for Span Powered xDSL xDSL A IN xDSL B IN A B C D E F J H Ground GND xDSL A OUT xDSL B OUT Management Bus Frame Ground 48 Vdc Battery Fuse Al...

Страница 24: ...gement Ports Table 1 3 J26 RS 232 X 25 Management Port DTE Note The HMU 319 requires that Data Set Ready DSR be asserted by the connected Data Communications Equipment DCE in order to establish commun...

Страница 25: ...eep individual CO equipment shelf with open faced mountings for natural convection cooling The maximum heat dissipation for open faced natural convection cooled mountings is limited to 134 7 Watts per...

Страница 26: ...ney heating effect see Air Flow Guidelines on page 1 15 for further information about cooling the HMS 318 List 3 shelf Outdoor cabinet applications require forced air to ensure proper cooling Figure 1...

Страница 27: ...oo warm an over temperature condition within the rack and the shelves that occupy it can occur The site should also be as dust free as possible Dust tends to clog the shelves reducing the flow of cool...

Страница 28: ...Chapter 1 Product Description December 20 2004 1 16 LTPH UM 1261 01...

Страница 29: ...g spaces or WECO with 2 in mounting spaces where the HMS 318 List 3 shelf will be housed Determine the location of any existing shelves and their interconnections including communications and power Th...

Страница 30: ...ur HMS 318 List 3 shelf You will need the packaging materials in the future if you move or ship your HMS 318 List 3 shelf Check 9 Item Quantity Catalog Part No Installer Initial HiGain Management Shel...

Страница 31: ...g or ESD preventive wrist strap 2 Phillips head screwdriver 1 Phillips head screwdriver Straight slot head screwdriver Cable preparation tools A 5 16 inch open end wrench Tape measure Wire strippers A...

Страница 32: ...utions must be followed to ensure safety They are Never wear loose clothing jewelry such as rings bracelets or chains or other items that could get caught in the shelf housing during handling and use...

Страница 33: ...ng the position of the brackets from a 2 or 5 inch recess mounting or vice versa ensure that you place the appropriate hardware screws washers and so on you remove in a convenient location for re asse...

Страница 34: ...As mentioned in Chapter 1 Product Description on page 1 1 and Mounting the HMS 318 List 3 Shelf on page 2 4 the adapter brackets are attached to the HMS 318 List 3 shelf at the factory for a 19 inch t...

Страница 35: ...nes on page xi and the Special Rack Mounting Precautions on page 2 4 before installing the HMS 318 List 3 shelf in the telco style equipment rack Step Action 1 Locate the telco style equipment rack po...

Страница 36: ...wered xDSL connections to the HMS 318 List 3 shelf ensure that the Main CO power breaker is off Otherwise severe injury to the installer or damage to the unit may result Step Action 1 Complete one of...

Страница 37: ...dure To connect the Bonding Safety ground to the HMS 318 List 3 Shelf complete the following steps IMPORTANT Before making connections to the HMS 318 List 3 shelf ensure that the Main CO power breaker...

Страница 38: ...ug location aligning the hole Insert the ground lug screw 12 Hexhead through the locking washer and then through the hole in the ground lug and the ground lug location on the HMS 318 List 3 Shelf Ensu...

Страница 39: ...st 3 shelf are powered by the 48VA bus Slots 12 through 22 are powered by the 48VB bus In the HMU HLU configuration the HMU 319 is diode OR ed to both power busses to guard against power failure in th...

Страница 40: ...shelf temperature exceeds 45 C 1 C and deactivates the relay when the temperature drops below 35 C 1 C If the temperature exceeds 77 C 1 C a critical alarm is also generated The critical alarm resets...

Страница 41: ...c wrist straps connected to the ESD Jack located on the right adapter bracket see Figure 1 on page 3 when inserting a circuit card Avoid touching components on the circuit card Step Action 1 Hold the...

Страница 42: ...of the circuit card toward you Align the top and bottom edges of the LPS 300C with the HMS 318 List 3 shelf slot guides 2 Slide the LPS 300C Power Module into its respective slot 3 Press the LPS 300C...

Страница 43: ...e Table A 4 on page A 5 Connector P1 DSX 1 Receive or Span Powered xDSL xDSL B IN Table A 1 provides signal and pin assignment information for making DSX 1 receive or Span Powered xDSL B IN circuit co...

Страница 44: ...ctions to the HMS 318 List 3 shelf Table A 2 P2 DSX 1 Transmit or Span Powered xDSL A IN Tip and Ring 14 Ring 40 15 Tip 15 Ring 41 16 Tip 16 Ring 42 17 Tip 17 Ring 43 18 Tip 18 Ring 44 19 Tip 19 Ring...

Страница 45: ...Tip 9 Ring 35 10 Tip 10 Ring 36 11 Tip 11 Ring 37 12 Tip 12 Ring 38 13 Tip 13 Ring 39 14 Tip 14 Ring 40 15 Tip 15 Ring 41 16 Tip 16 Ring 42 17 Tip 17 Ring 43 18 Tip 18 Ring 44 19 Tip 19 Ring 45 20 Tip...

Страница 46: ...n Powered xDSL xDSL A OUT connections to the HMS 318 List 3 shelf Table A 3 P3 HDSL Span 1 or Span Powered xDSL A OUT Tip and Ring Cable Pin Number Slot Card Slot Pin Number 26 1 Tip 1 Ring 27 2 Tip 2...

Страница 47: ...SL B OUT connections to the HMS 318 List 3 shelf Table A 4 P3 HDSL Span 1 or Span Powered xDSL A OUT Tip and Ring 18 Ring 44 19 Tip 19 Ring 45 20 Tip 20 Ring 46 21 Tip 21 Ring 47 22 Tip 22 Ring Cable...

Страница 48: ...4 A 6 LTPH UM 1261 01 12 Ring 38 13 Tip 13 Ring 39 14 Tip 14 Ring 40 15 Tip 15 Ring 41 16 Tip 16 Ring 42 17 Tip 17 Ring 43 18 Tip 18 Ring 44 19 Tip 19 Ring 45 20 Tip 20 Ring 46 21 Tip 21 Ring 47 22 Ti...

Страница 49: ...C Color Code Pair Number Tip Ring 1 White Blue 2 White Orange 3 White Green 4 White Brown 5 White Slate 6 Red Blue 7 Red Orange 8 Red Green 9 Red Brown 10 Red Slate 11 Black Blue 12 Black Orange 13 Bl...

Страница 50: ...Appendix B Standard PIC Color Code December 20 2004 B 2 LTPH UM 1261 01...

Страница 51: ...nce measurement should be between 1 and 10 Mohms STORING CIRCUIT CARDS Spare circuit cards must be left in the original shipping container until required To prevent damage to circuit cards while they...

Страница 52: ...eep the circuit cards in their protective bags Step Action 1 Remove any front panel cables from the circuit card 2 Grasp the circuit card at the top or bottom ejector tab or the built in thumb hold an...

Страница 53: ...sions HxWxD 5 22 in x 19 in x 12 in 13 3 cm x 48 3 cm x 30 5 cm without mounting brackets Weight 17 lb 7 7 kg Capacity 1 HMU Management Module and 22 HLU Modules or 22 ELU Modules or 11 LPS 300C Power...

Страница 54: ...ng in either 19 inch 48 3 cm or 23 inch 58 4 cm bays Brackets for mounting in ETSI rack Accessories Available Extender Bracket Kit available in three colors EB 52 gray EB 52B black EB 52P putty a If f...

Страница 55: ...nitoring upstream or downstream Power Monitoring and Remote Surveillance Service Maintenance Agreements and Systems Operation ADC Technical Assistance Center 800 366 3891 Email wsd support adc com Tec...

Страница 56: ...Appendix E Product Support December 20 2004 E 2 LTPH UM 1261 01...

Страница 57: ...ETSI European Telecommunications Standard Institute F FCC Federal Communications Commission FGND Frame Ground G G SHDSL Single pair High speed Digital Subscriber Line G 703 ITU T Recommendation for p...

Страница 58: ...ces port P PIC Plastic Insulated Conductor R RCV Receive RMA Return Material Authorization RX Receive S SYS ID System Identifier alarm T T1 1 544 Mbps data rate North American V VIS Visible alarm W WE...

Страница 59: ...nty is determined by your service agreement Refer to the ADC Warranty Software Handbook for additional information or contact your sales representative or Customer Service for details Modifications Th...

Страница 60: ...Minneapolis MN 55440 1101 USA For Technical Assistance Tel 800 366 3891 HiGain Managed Shelf 19 inch 3190 Mechanic 22 Slot Managed CO Shelf HMS 318 List 3 User Manual Document Number Product Catalog H...

Отзывы: