December 20, 2004
Chapter 1: Product Description
LTPH-UM-1261-01
1-7
In the HMU/HLU configuration, for example, for detailed information about the different types of alarms, refer to the
“Managing Alarms” section in the
HMU-319, H2TU-C-319, or H4TU-C-319 User Manuals
. Specifically, the manual
describes the types of alarms the HMU-319 reports, when the alarm occurs, and how to respond to the alarm using
the ACO.
Table 1-2. Alarms Wire-wrap Field Functional Description
Alarm
Alarm Description
Function
CRIT AUD
Critical Audible
There is a critical alarm active on the HMS-318
List 3 shelf. Connect this relay to the critical
alarm audible indicator of the CO alarm
system.
CRIT VIS
Critical Visible
There is a critical alarm active on the HMS-318
List 3 shelf. Connect this relay to the critical
alarm visual indicator of the CO alarm system.
MAJ AUD
Major Audible
There is a major alarm active on the HMS-318
List 3 shelf. Connect this relay to the major
alarm audible indicator of the CO alarm
system.
MAJ VIS
Major Visible
There is a major alarm active on the HMS-318
List 3 shelf. Connect this relay to the major
alarm visual indicator of the CO alarm system.
MIN AUD
Minor Audible
There is a minor alarm active on the HMS-318
List 3 shelf. Connect this relay to the minor
alarm audible indicator of the CO alarm
system.
MIN VIS
Minor Visible
There is a minor alarm active on the HMS-318
List 3 shelf. Connect this relay to the minor
alarm visual indicator of the CO alarm system.
SYS ID
System ID
There is a critical, major, or minor alarm active
on the HMS-318 List 3 shelf. Connect this relay
to the equipment rack alarm indicator.
ACO
Alarm Cutoff
External Alarm Cutoff (ACO) function silences
active audible alarms (see
“Alarm Cutoff
(ACO)” on page 1-6
).
GND
Ground
External ground
EXT TEMP
External Temperature
Thermostat
Thermal control (digital temperature sensor).
Connect this pin to an external snap-action
thermostat to activate the fan relay. This
thermostat provides a switch closure to ground
that is sensed by the HMU-319.
NO COM FAN
Fan Control
The Fan Control manually disables a Fan
Assembly using the NO and COM fan control
contacts.
Содержание HiGain HMS-318 List 3
Страница 4: ...Table of Contents December 20 2004 iv LTPH UM 1261 01...
Страница 6: ...List of Figures December 20 2004 vi LTPH UM 1261 01...
Страница 8: ...List of Tables December 20 2004 viii LTPH UM 1261 01...
Страница 28: ...Chapter 1 Product Description December 20 2004 1 16 LTPH UM 1261 01...
Страница 50: ...Appendix B Standard PIC Color Code December 20 2004 B 2 LTPH UM 1261 01...
Страница 56: ...Appendix E Product Support December 20 2004 E 2 LTPH UM 1261 01...