background image

e-sphyg

TM

Digital Aneroid

AMERICAN DIAGNOSTIC CORPORATION

®

User’s

Manual

IB p/n 9359-00 rev 4                                                                                         Printed in the U.S.A.

ADC
55 Commerce Drive
Hauppauge, NY 11788

ADC (UK) Ltd.
Unit 6, PO14 1TH
United Kingdom

EC

REP

Inspected in the U.S.A.

Made in China

tel: 631-273-9600, 1-800-232-2670

fax: 631-273-9659

www.adctoday.com

email: [email protected]

©2007 ADC. All rights reserved. No one is permitted to reproduce or duplicate
in any form, this manual or any part thereof without the expressed written
permission of ADC. ADC assumes no responsibility for any injury to anyone, or
for any illegal or improper use of the product that may result from failure to use
the product in accordance with the instructions, cautions, warnings, or
statement of intended use published in this manual. The 7002/8002 e-sphyg

TM

is

a trademark of ADC.

0197

Содержание E-Sphyg 7002

Страница 1: ...m email info adctoday com 2007 ADC All rights reserved No one is permitted to reproduce or duplicate in any form this manual or any part thereof without the expressed written permission of ADC ADC ass...

Страница 2: ...he finest sphygmomanometers that money can buy With proper care and maintenance your ADC blood pressure instrument is sure to provide you with many years of depend able service Please read the followi...

Страница 3: ...normal use and service as follows 1 Warranty service extends to the original retail purchaser only and commences with the date of delivery 2 The entire sphygmomanometer is warranted for one year 3 The...

Страница 4: ...and accuracy of your new digital e sphygTM gauge Using state of the art technology your e sphygTM will provide digital accuracy with tank like reliability Intended Use ADC aneroid digital aneroid and...

Страница 5: ...A warning statement in this manual identifies a condition or practice which if not corrected or discontinued immediately could lead to patient injury illness or death NOTE Systolic Assist and pulse m...

Страница 6: ...utton On Off Zeroing Button Artery Mark Air Tube and Connector Air Release Valve Inflation Bulb Splash Resistant Housing Extra Large LCD Display Error Message Description Solution ERROR DISPLAYS and T...

Страница 7: ...nician is qualified to perform this calibration service Do not attempt to recalibrate the gauge yourself In addition to the visual inspection indicated above we also recommend you perform the followin...

Страница 8: ...the backlight off at any time press the button on the left side You will need to deactivate the backlight each time you power on the instrument Assembling your Sphygmomanometer Your inflation system i...

Отзывы: