background image

    •  The maximum charging time for NiMH rechargeable batteries is 
        limited to <650 minutes (10.8 hours). The maximum charging time for 
        Li-ion rechargeable batteries is limited to <480 minutes (8 hours). 

    •  When the rechargeable battery is fully charged (green LED on), the 
        unit will switch to maintenance charge. 

    •  The temperature inside the charger base is monitored. Do not keep 
        in sunlight, or close proximity of a radiator, as over heating may 
        cause premature actuation of the automatic switch-off mechanism 
        shutting the charger off before completing a full charge. 

 

Caution: 

 

   •  When the handle is removed from the charging chamber for a few 

        seconds while the rechargeable battery is fully charged (green LED on) 
        without switching on, initially the yellow charging LED will be switched 

        on when reinserting the unused rechargeable 

        battery. However, this is not due to 
        malfunction of the charging base but the 
        described “rechargeable battery full” sensor. 

 

    •  When the rechargeable battery is full, no 
        negative voltage differential can be recorded. 
        The rechargeable battery must first heat up in 
         order to signal “rechargeable battery fully charged.” 

 

• The time prior to the green “rechargeable 

battery fully charged” LED switching on 
again may vary considerably (15 minutes 
or longer). Additional temperature sensing 
and a timer, however, ensure that the 
charging process is carefully monitored at 
any time.

 

 

We recommend keeping the instrument in the 
charging chambers after use to ensure that instruments are always ready.

 

11. TECHNICAL SPECIFICATIONS

 

Model:                                      

ADC

 

Rechargeable Battery Charger Base 

Display System:                      

LEDs Connection 

Main Connection                     

(See Note on Bottom Label) 

Power Adapter Input:             

100 V-240 V AC / 50-60 Hz/0.6 A 

Power Adapter Output:           

9 V DC/2 A/18 W 

Classification:                         

Applied part type B 

Operating Conditions:             

32°F to 104°F (0°C to 40°C) 

                                                    10% to 85% relative humidity 

Storage Temperature:             

23°F to 122°F (-5°C to 50°C) 

                                                

10% to 85% relative humidity 

Air Pressure:                           

700 to 1050 hPa 

Dimensions:                            

7.3” x 3.4” x 2.9” (186 mm x 87 mm x 74 mm) 

Weight:                                    

Approx. 1.1 lbs (500 g) without packing

 

12. MAINTENANCE

 

These instruments and their accessories do not require any specific 
maintenance. Should an instrument have to be examined for any specific 
reason whatsoever, please return it to ADC. 

13. ELECTROMAGNETIC COMPATIBILITY (EMC)

 

Follow the instructions during the installation and operation of the device. 
To avoid electromagnetic interference with the operation of the device, do not 
use the device at the same time as other electronic devices. 
To avoid electromagnetic interference with the operation of the device, do not 
use or stack the device near, on or under other electronic devices. 
Do not use the device in the same room as other electronic devices, (e.g. life-
supporting devices that have a significant impact on the life of the patient and 
treatment outcomes) or other measuring instruments or treatment devices that 
use little electrical power. 
Do not use cables or accessories that are not  specified for this device, as this 
can increase the emission of electromagnetic waves from the device and reduce 
the device’s electromagnetic immunity.

 

 

 

7

10

Содержание Diagnostix 5500N

Страница 1: ...0 3 23 2021 Printed in U S A Made in Germany Inspected and Packaged in the U S A tel 631 273 9600 toll free 1 800 232 2670 fax 631 273 9659 www adctoday com email info adctoday com Consult instruction...

Страница 2: ...Desk Charging Base is warranted for 2 years from date of purchase This warranty includes the instrument The warranty does not apply to damage caused by improper handling accidents improper use or alt...

Страница 3: ...use specified in the instructions for use Recommended distances between portable and mobile RF communications equipment and the charging stations The charging station is intended for use in an electro...

Страница 4: ...ons The electromagnetic propagation is affected by absorption and reflection by structures objects and people a Field strengths from fixed transmitters such as base stations for radio mobile cordless...

Страница 5: ...manufacturer s declaration electromagnetic immunity The charging station is intended for use in the electromagnetic environment specified below The customer or user of the charging station should ensu...

Страница 6: ...rechargeable battery voltages of more than 1 5V charging will commence The yellow charging LED will turn on c Charging Time The end of the charging time is detected by evaluation of the negative volta...

Страница 7: ...nsure that instruments are always ready 11 TECHNICAL SPECIFICATIONS Model ADC Rechargeable Battery Charger Base Display System LEDs Connection Main Connection See Note on Bottom Label Power Adapter In...

Страница 8: ...t mains cable from socket Cleaning and or Disinfection The ADC Diagnostix Desk Charging Base may be cleaned externally with a damp cloth In addition the following disinfectants may be used for externa...

Отзывы: