19
F. ELECTRICAL INFORMATION
1. ELECTRICAL REQUIREMENTS
It is your responsibility to have all electrical connections made by a properly licensed and
competent electrician to assure that the electrical installation is adequate and conforms with local
and state regulations or codes. In the absence of such codes, ALL electrical connections, material,
and workmanship must conform to the applicable requirements of the National Electrical Code
ANSI/NFPA NO.70-LATEST EDITION..
IMPORTANT
: Failure to comply with these codes or ordinances, and/or the requirements
stipulated in this manual can result in personal injury or component failure.
NOTE
:
Component failure due to improper installation will
VOID THE WARRANTY.
Each dryer
should be
connected to an independently protected branch circuit. The dryer
must be
connected with copper wire only.
DO NOT
use aluminum wire which could cause a fire hazard.
The copper conductor wire/cable
must be
of proper ampicity and insulation in accordance with
electric codes for making all service connections.
NOTE
:
The use of aluminum wire will
VOID THE WARRANTY.
IMPORTANT
:
A separate circuit servicing each dryer
must be
provided.