background image

ADCP-75-237 • Issue 1 • 8/2007 • Preface

Page x

© 2007, ADC Telecommunications, Inc.

radio communications. 

Changes and modifications not expressly approved by the manufacturer or registrant of this 
equipment can void your authority to operate this equipment under Federal Communications 
Commissions rules.

In order to maintain compliance with FCC regulations, shielded cables must be used with this 
equipment. Operation with non-approved equipment or unshielded cables is likely to result in 
interference to radio & television reception.

ETL

: This

 

equipment

 

complies

 

with

 

ANSI/UL 60950-1

 

Information Technology

 

Equipment.

This

 

equipment

 

provides

 

the

 

degree

 

of

 

protection

 

specified

 

by

 

IP24

 

as defined

 

in

 

IEC

Publication

 

529.

 

Ethernet signals are not for outside plant use.

FDA/CDRH

: This

 

equipment

 

uses

 

a

 

Class

 

1

 

LASER

 

according

 

to

 

FDA/CDRH

 

Rules.

 

This 

product

 

conforms

 

to

 

all

 

applicable

 

standards

 

of

 

21

 

CFR

 

Part

 

1040.

IC

: This

 

equipment

 

complies

 

with

 

the

 

applicable

 

sections

 

of

 

RSS-131.

 

The

 

term

 

“IC:”

 

before

the radio

 

certification

 

number

 

only

 

signifies

 

that

 

Industry

 

Canada

 

Technical

 

Specifications

were

 

met.

Wind Loading

: The NXD RAN is able to withstand wind loads up to 150 mph.

LIST OF ACRONYMS AND ABBREVIATIONS

Below is an example of a list of this type.

The acronyms and abbreviations used in this manual are detailed in the following list:

AC

Alternating Current

ANT

Multiband Antenna

BIM

Base Station Interface Module

BTS

Base Transceiver Station

C

Centigrade

CDRH 

Center for Devices and Radiological Health

C/MCPLR

Cellular SMR Multicoupler

CM

Centimeter

cPCI

CompactPCI

CPU

Central Processing Unit

CXD

Compact RAN

DAS

Distributed Antenna System

dB(FS)

decibals (Full Scale – digital reading)

DC

Direct Current

Div

Diversity

EMS

Element Management System

ESD

Electrostatic Discharge

F

Fahrenheit

Содержание ADCP-75-237

Страница 1: ...ADC In Building 850 and 1900MHz Wireless Repeater User Manual 1xxxxxx Rev A ADCP 75 237 Issue 1 8 2007...

Страница 2: ......

Страница 3: ...ADC In Building 850 and 1900MHz Wireless Repeater User Manual ADCP 75 237 Issue 1 8 2007 1xxxxxx Rev A...

Страница 4: ...prior notice In no event shall ADC be liable for any damages resulting from loss of data loss of use or loss of profits and ADC further disclaims any and all liability for indirect incidental special...

Страница 5: ...SCRIPTION 1 1 1 1 RF SIGNAL FLOW 850MHz 1 1 1 2 RF SIGNAL FLOW 1900MHz 1 2 2 FEATURES 1 3 2 1 LED Status 1 3 2 2 Automatic Level Control ALC 1 3 2 3 Sleep Mode 1 3 2 4 Isolation Check 1 3 2 5 Over Pow...

Страница 6: ...Band Selection 3 11 4 4 Attenuation Test MGC ALC Control 3 11 4 5 Gain Offset Box 3 11 4 6 Fwd PLL Attenuation Control 3 11 4 7 Rev Pll Attenuation Control 3 11 SECTION 4 GENERAL INFORMATION 1 WARRAN...

Страница 7: ...ion Caution is used to indicate the presence of a hazard that will or can cause minor personal injury or property damage if the hazard is not avoided GENERAL SAFETY PRECAUTIONS List here all general a...

Страница 8: ...It has been tested and found to comply with limits for a Class A digital device pursuant to Subpart B of Part 15 of FCC Rules which are designed to provide reasonable protection against such interfere...

Страница 9: ...of UL CSA 60950 XXX modules and chassis have been tested and found to comply with all applicable CE Directives XXXX complies with the requirements of GR 63 CORE Issue 1 October 1995 and GR 1089 CORE I...

Страница 10: ...ss 1 LASER according to FDA CDRH Rules This product conforms to all applicable standards of 21 CFR Part 1040 IC This equipment complies with the applicable sections of RSS 131 The term IC before the r...

Страница 11: ...Amplifier PAA Power Amplifier Assembly PC Personal Computer PCI Peripheral Component Interconnect bus PIC PA Interface Controller P MCPLR PCS Multicoupler RAN Radio Access Node RDC RAN Down Converter...

Страница 12: ...ADCP 75 237 Issue 1 8 2007 Preface Page xii 2007 ADC Telecommunications Inc...

Страница 13: ...ted on a rooftop or external wall of a building directed at the donor cell site The repeater is mounted inside the building and distributes the RF over coax to an indoor antenna located in the desired...

Страница 14: ...through a BPF Band Pass Filter then is amplified by the drive amplifier The signal than goes through the LNA and a Down Mixer where IF signal conversion is done This IF signal then goes through an IF...

Страница 15: ...k Isolation check LED for the forward path and reverse path comes on after the Donor antenna is set up and the power is turned on Automatic Gain set up is available within the repeater for the Path Is...

Страница 16: ...45 846 5 B 891 5 894 846 5 849 2 6 2 1900MHZ Repeater Band Selection Band selection is available within the US PCS 60MHz bandwidth You can select any A B or C band 15MHz each group1 and any D E or F b...

Страница 17: ...hown in Figure 2 1 Below are guidelines for standard wall mount and masonry wall mount of the repeater Figure 2 1 Wall Mount Bracket 1 1 Mechanical Attachment of Repeater Warning Never install the rep...

Страница 18: ...connectors one power connector and one USB port A USB cable is required when configuring the repeater using the GUI Plug one end of the USB cable into the port on the bottom of the repeater and plug t...

Страница 19: ...PDU ALARM connector 4 Connect the power cable to the site DC power connector The power cable has three leads Red is positive Black is negative and Yellow Green is for ground 5 Connect the power cable...

Страница 20: ...ADCP 75 237 Issue 1 8 2007 Section 2 Installation Page 2 4 2007 ADC Telecommunications Inc...

Страница 21: ...Volt 3 10 4 2 Rev Base Volt 3 11 4 3 Band Selection 3 11 4 4 Attenuation Test MGC ALC Control 3 11 4 5 Gain Offset Box 3 11 4 6 Fwd PLL Attenuation Control 3 11 4 7 Rev Pll Attenuation Control 3 11 __...

Страница 22: ...3 2 2007 ADC Telecommunications Inc Program automatically creates a default directory to install the program in If you wish to change the installation directory select Change Directory button to manu...

Страница 23: ...7 Section 3 Graphical User Interface Page 3 3 2007 ADC Telecommunications Inc Choose a Program Group where program is to be installed By default the program creates a new program group named Pcs_Repea...

Страница 24: ...cations Inc If this software program is using an older window database there is a version conflict Keep the original file by clicking Yes Successful installation completed Click OK button The window w...

Страница 25: ...to Windows Start menu Program Pcs_Repeater program group Click Pcs_Repeater to start program The following screen displays the start window of the program 2 1 Menu Information Setting Connection opti...

Страница 26: ...n output power is equal to or higher than the registered value the signal button turns red Isolation Check RUN button is active Pressing the RUN button starts the isolation check When the Isolation Ch...

Страница 27: ...art Freq Lo Freq stop Freq start Freq Lo Freq stop Freq A A 869 951 5 880 824 951 5 835 B 880 890 835 845 A 890 891 5 845 846 5 B 891 5 894 846 5 849 1900MHz Band Selection A B C x 15MHz path band A B...

Страница 28: ...the connected port number Properties Window bottom line Properties shows the property information Note You must install a USB driver to use the USB port After installing the driver the software recog...

Страница 29: ...t None H W Select both All options may use default settings except for Port You must select correct port that the computer is connected to the equipment with After finishing the selection press OK to...

Страница 30: ...system and click 1dB Read button This will read the forward path voltage and show in the text box Input 1dB signal to the repeater system and click 1dB Read button This will read the forward path volt...

Страница 31: ...4 4 Attenuation Test MGC ALC Control Press up down arrow key to adjust the Manual Gain Control in 0 5dB increments Press up down arrow key to adjust the Automatic Level Control in 0 5dB increments 4 5...

Страница 32: ...ADCP 75 237 Issue 1 8 2007 Section 3 Graphical User Interface Page 3 12 2007 ADC Telecommunications Inc Blank...

Страница 33: ...ducts are available at a nominal fee Contact the Technical Assistance Center at 1 800 366 3891 extension 73476 in U S A or Canada or 952 917 3476 outside U S A and Canada for software service agreemen...

Страница 34: ...will charge the current price of a field visit plus round trip transportation charges from Minneapolis to the Buyer s site 5 REPLACEMENT SPARE PRODUCTS Replacement parts including but not limited to b...

Страница 35: ......

Страница 36: ...l Assistance 32 2 712 65 42 EUROPEAN TOLL FREE NUMBERS Germany 0180 2232923 UK 0800 960236 Spain 900 983291 France 0800 914032 Italy 0800 782374 ASIA PACIFIC Sales Administration 65 6294 9948 Technica...

Отзывы: