150-402-111-02
Provisioning the HRU-402
HRU-402 List 1A
December 8, 1998
21
system to an ASCII terminal or a PC running a terminal emulation program.
To connect a terminal emulator:
1
Connect a standard, 9-pin, serial terminal cable to the Craft port
(RS-232 DB-9 connector) on the HRU-402.
shows the
HRU-402 DB-9, and two types (DB-9 and DB-25) of RS-232 I/O
interfaces on the maintenance terminals (PCs).
2
Once the serial cable is connected to the Craft port (RS-232 DB-9
connector) on the HRU-402, connect the other end of the cable to the
9-pin or 25-pin COM port (RS-232) of the maintenance terminal
(
). The maintenance terminal is configured as Data
Terminal Equipment (DTE).
Figure 8.
Connecting the HRU-402 to a Maintenance Terminal
3
Configure the maintenance terminal to the following communication
settings:
•
1200 to 9600 baud (9600 baud is recommended)