The nameplate is located on the side of the device (example: RELIANCE-C Remote single channel).
Figure 2: Nameplate of the RELIANCE Remote Duel Channel
For commissioning, the serial number on the nameplate (e.g. serial number 4015000220, see
) must be recorded. This
is then utilized for installation and configuration.
2.2.4.4 Storage
When storing the device, it is advisable to leave it in its original packaging. The storage temperature is shown in
Storage Temperature: Remote: -67°F to +167°F (-55°C to +75°C)
2.2.5 View of the device with connections
Figure 3: View of the RELIANCE Remote Dual Channel
X1
X4
X3
5. Reliance Remote, Dual Channel
4. Ground Screw
X2
6. Remote ID Label
1. Cable with 2-pin plug (in compliance with FAA L-823) for connection to the series circuit isolation transformer (X3)
2. Cable with 2-pin socket (in compliance with FAA L-823) for connection to the light on channel A (X1)
3. Cable with 2-pin socket (in compliance with FAA L-823) for connection to the light on channel B (for dual Remote only)
(X4)
4. Ground cable connection (X2)
5. RELIANCE Remote housing
6. RELIANCE Remote Label for Remote ID number.
Note
See nameplate of RELIANCE Remote (
) for identification of connections marked “X”.
RELIANCE-C Remote Control Device
RELIANCE Remote
12
Copyright
©
ADB Safegate, All Rights Reserved
Содержание RELIANCE AGLAS-C
Страница 2: ......
Страница 6: ...RELIANCE C Remote Control Device TABLE OF CONTENTS vi Copyright ADB Safegate All Rights Reserved ...
Страница 10: ...RELIANCE C Remote Control Device Safety 4 Copyright ADB Safegate All Rights Reserved ...
Страница 22: ...RELIANCE C Remote Control Device RELIANCE Remote 16 Copyright ADB Safegate All Rights Reserved ...
Страница 34: ...RELIANCE C Remote Control Device Parts 28 Copyright ADB Safegate All Rights Reserved ...
Страница 38: ......