Individual control of different functions in one lamp circuit. For example, a combination of Stop Bar and Lead-In Circuit.
•
Optional Runway Guard Light Remotes, automatic start and net-synchronous Wig-Wag operation, independent from
Master meeting FAA requirements.
•
Firmware and application software can be downloaded into either the Master (substation) or Remotes (field units).
•
State-of-the-art diagnostic tools provide a quick overview about communication behavior. Network management system
provides detailed routing statistics to ensure reliable communication quality.
•
Communication measurements can be taken in advance within one day to analyze existing airfield infrastructure.
•
Field sensors can be integrated via Utility Remotes into the RELIANCE Intelligent Lighting lamp control and monitoring
circuit for detection and transmission of local surveillance information via power line communication.
•
Able to work with any kind of CCR and designed for 40 Ampere peak current.
Main Characteristics and Figures
•
Up to 300 Remotes per circuit, providing a potential of 600 individually addressable lights per circuit.
•
Up to 20 km roundtrip circuit length.
•
Configurable block evaluation modes include full feedback, small sample feedback, and optimistic feedback.
•
Can command 10 blocks to 10 distinct states with one power-line message. Can command all blocks to one state with one
powerline message.
•
Switches up to 120 lights in 10 different groups in less than 1 second.
•
Switches 5 stopbar/lead-on lights simultaneously and presents real-back indication in less than 1 second.
•
Status poll provides detailed Remote and lamp parameters.
Integrated System Control
Overall system configuration and control is realized via a control process with integrated web server for configuration and
maintenance.
•
Each circuit is equipped with a microprocessor-controlled Master for tracking, recording and management of state of all
Remotes in the circuit.
•
The Master communicates with all the Remotes (not light fixtures) in a circuit and polls all lamps independent from the
control system.
Overall System Specifications
Description
Remote
Master
Operating temperature
-40 °C to +65 °C
0 °C to +55 °C
Storage temperature
-55 °C to +85 °C
-40 °C to +75 °C
Operating humidity
Max. 100 %
Max. 95 % non condensing
Series circuit operating voltage
-
Max. 5000 V AC RMS
Min. / max. Power line current
1.8 up to 6.9 A RMS
1.8 up to 6.9 A RMS
Series circuit peak voltage
-
Max. 15 kV
Maximum switching power secondary side of
transformer
300 W (single Remote) Ch A + Ch B < 300 W
(dual)
-
Maximum circuit load (CCR power)
-
30 kVA
Power consumption
Max. 8 W at 6.6 A
Max. 15 W for power supply 115-230 V Max.
65 W on primary circuit at 6.6 A
RELIANCE-C Remote Control Device
RELIANCE Remote
8
Copyright
©
ADB Safegate, All Rights Reserved
Содержание RELIANCE AGLAS-C
Страница 2: ......
Страница 6: ...RELIANCE C Remote Control Device TABLE OF CONTENTS vi Copyright ADB Safegate All Rights Reserved ...
Страница 10: ...RELIANCE C Remote Control Device Safety 4 Copyright ADB Safegate All Rights Reserved ...
Страница 22: ...RELIANCE C Remote Control Device RELIANCE Remote 16 Copyright ADB Safegate All Rights Reserved ...
Страница 34: ...RELIANCE C Remote Control Device Parts 28 Copyright ADB Safegate All Rights Reserved ...
Страница 38: ......