CAUTION
Per FAA AC 150/5340-30, Chapter 10, and FAA Engineering Brief No 83 (latest revision), it is extremely important that
other types of washers, such as split washers, must not be used. Failure to use properly installed anti-vibration lock
washers will cause mounting bolts to become loose. The cams (or steps) of each half of the lock washer must face
each other.
4.3.4 Safety Considerations
Read the installation section of all system component manuals before starting these steps. A thorough understanding of
system components and their requirements will promote safe and efficient installation. See FAA AC 150/5340-30, Design
and Installation Details for Airport Visual Aids, and site plans and specifications for field installation of runway and taxiway
in-pavement lights.
DANGER
Failure to follow these safety procedures can result in personal injury or death.
•
Allow only qualified personnel to install ADB SAFEGATE and auxiliary equipment. Use only approved equipment.
Using unapproved equipment in an approved system may void FAA approvals. Observe and follow the safety
instructions in this document and all other related documentation.
•
Make sure all equipment is rated and approved for the environment where it is being used.
•
Follow all instructions for installing components and accessories.
•
Install all electrical connections in compliance with local and national codes and regulations.
•
Use only electrical wire of sufficient gauge and insulation to handle the rated current demand. All wiring must
meet local and national codes.
•
Route electrical wiring along a protected path. Make sure it will not be damaged by moving equipment.
•
Protect components from damage, wear and harsh environmental conditions.
•
Allow ample clearance for maintenance, panel accessibility and cover removal.
•
Protect equipment with safety devices as specified by applicable safety regulations.
•
If safety devices must be removed for installation, reinstall them immediately after the work is completed and
check them for proper functioning.
•
The cord set must be protected prior to installation.
4.3.5 Photobiological safety
CAUTION
Photobiological safety conforming with IEC 62471
RISK GROUP 0 or 1: Optical radiation emitted from LED lights may be harmful to the eyes. Do not stare with at
the light source with bare eyes at a fixture operating at high intensity. Use protection goggles or similar protection
method.
Goggles with a transmission factor not higher than 5% in the 400-530 nm band have been tested and provide
adequate protection.
AXON Taxiway Inset Lights, 8-inch and 12-inch
Installation
18
Copyright
©
ADB Safegate, All Rights Reserved
Содержание AXON FAA L-852A
Страница 2: ...UM 5056 Rev 1 0 17 2022 12 08 ...
Страница 10: ...AXON Taxiway Inset Lights 8 inch and 12 inch List of Tables x Copyright ADB Safegate All Rights Reserved ...
Страница 23: ...Figure 3 12 inch Taxiway Lights UM 5056 Rev 1 0 17 2022 12 08 13 Copyright ADB Safegate All Rights Reserved ...
Страница 24: ...AXON Taxiway Inset Lights 8 inch and 12 inch Introduction 14 Copyright ADB Safegate All Rights Reserved ...
Страница 51: ...6 0 Ordering Codes UM 5056 Rev 1 0 17 2022 12 08 41 Copyright ADB Safegate All Rights Reserved ...
Страница 62: ...AXON Taxiway Inset Lights 8 inch and 12 inch Ordering Codes 52 Copyright ADB Safegate All Rights Reserved ...
Страница 90: ...AXON Taxiway Inset Lights 8 inch and 12 inch INTEROPERABILITY 80 Copyright ADB Safegate All Rights Reserved ...
Страница 92: ...AXON Taxiway Inset Lights 8 inch and 12 inch POWER TABLE 82 Copyright ADB Safegate All Rights Reserved ...
Страница 94: ...AXON Taxiway Inset Lights 8 inch and 12 inch CABLE LOSS 84 Copyright ADB Safegate All Rights Reserved ...
Страница 98: ......