If you see a green light + red light blinking
Program P1 – Lower temperature at night (night-time heating)
By activating programme P1, the temperature is automatically reduced by 5 °C for 7 hours.
Note: the programme must be activated when you require the lower temperature: e.g. 11 PM.
P1 must be activated at the time you require the lower temperature at night. When P1 is activated, the reduction
in temperature will be activated in the evening/night automatically.
for night-time heating has not been specified
.
when this module is selected, the start time
Activating P1 – Night-time heating
1. The programme must be activated at the time you wish to reduce the temperature at night (e.g. 10.30 PM)
2. Turn the control dial to P1 (P1- set to the light)
3.
Press the control dial once. If the time is not given, a green light will blink!
4. Press and hold in the control dial for 2 seconds until the green light blinks
5.
Turn the control dial to the required temperature (22 degrees) and confirm by depressing the control dial.
Programme
P1
will then reduce the temperature from 22 °C to 17 °C for 7 hours. After 7 hours, the radiator will warm up to 22°C.
If the temperature is adjusted when night-time heating is set, the updated temperature will be reduced by 5°C.
If a different
“
comfort
”
temperature is required, e.g. 22°C, this can easily be adjusted by setting a new
“
comfort
”
temperature (e.g. 20°C.
The reduced night-time temperature will then be 15°C).
Changing starting time for P1 – Lower temperature at night (night-time heating)
1. Reactivated when the required starting time for night-time heating is set: e.g. 10 PM
2. Follow steps 2
–
5 under activating night-time heating.
Manuel mode
When activating the manual mode, the desired temperature is set by turning the control dial.
The radiator is heating up when the red light is on. When the green light is on, the room has reached the set
temperature.
1.Turn the control dial to the hand symbol
and press once to confirm
Set the desired temperature you require. Adjust for night-time heating and/or set the temperatureto 5°C if the radiator
is set to guard against frost in a shed or holiday home.
Open window
This setting is set to Off by default. By registering an open window, it makes it possible to detect
an open window (registering a suddenly change in temperature). When the radiator senses a window is open,
the temperature is automatically set to anti-frost mode (7°C). When the window is closed
–
i.e. when the zone
temperature starts to increase
–
the radiator automatically reverts to the previous set temperature.
Activate / Deactivate Open window
1. Turn the control dial to the hand symbol
–
Press to confirm
2. Turn the control dial to 13°C
3. Status
–
Press in the control dial for 1 second twice
–
the green light will blink
a.
Open window is activated
–
Green light shows
b. Open window is deactivated
–
Red light shows
4. Turn Open window off or on
a.
Turn the control dial to the left to turn off
–
The LED light will turn red
–
Press the dial in to confirm. The green light will blink
b.
Turn the control dial to the right to turn on
–
The LED light will turn green
–
Press the dial in to confirm. The green light will blink
5. When either is turned off or on
–
adjust to the desired temperature.