TouchEntry

®

-XT

1.3.3 Connections of the terminal

Bottom

Ethernet, 10/100BaseT mit RJ45-Buchse

2-wire socket (for option 2-wire kit)

Wiegand output

1 x Trigger input and 1 x Tamper contact or 2 x Tamper contacts

1 x Relay, e.g. door opener

1 x TTL output

Installation

4

Содержание TouchEntry-XT

Страница 1: ...TouchEntry XT Installation Manual Updated 02 2020 Version 0 9 ...

Страница 2: ... 3 x RFID cards green red grey mounting kit 1 x installation manual 1 2 Location Indoor and outdoor use 20 C to 60 C temperature range The terminal is suitable for outdoor use with high brightness However a direct incidence of sunlight into the lenses morning evening sun should be avoided Recommended mounting height 1 57 m Center of the terminal Installation 2 ...

Страница 3: ...er supply via Ethernet PoE a PoE capable switch or a PoE injector is required 1 3 2 2Wire connection If the terminal was ordered with the 2Wire option the wire ends of the 2Wire cable must be connected to the 2Wire socket For long distances it is important to ensure a sufficient wire cross section For more information refer to the installation guide and manual of the 2Wire converter Installation 3...

Страница 4: ...s of the terminal Bottom Ethernet 10 100BaseT mit RJ45 Buchse 2 wire socket for option 2 wire kit Wiegand output 1 x Trigger input and 1 x Tamper contact or 2 x Tamper contacts 1 x Relay e g door opener 1 x TTL output Installation 4 ...

Страница 5: ...he following the flush mounting is shown Surface mounting can be done in the same way Use the appropriate wall bracket Flush mounted Surface mounted 1 Using the Allen key turn the screws below the display flush mount or the screw below the terminal surface mount counterclockwise until the terminal can be pushed upwards and detached from the wall bracket Flush mounted Surface mounted 2 Installation...

Страница 6: ...ousing to mark the drill holes Make sure that the flush mounted housing is oriented correctly When correctly mounted the opening for the cables is located in the lower half Pull the Ethernet cable through the cut out on the back of the terminal Use the screws seals and dowels from the mounting kit to fix the flush mounted housing to the wall Installation 6 ...

Страница 7: ...the seal into the cut out in the back of the flush mounted housing 6 Plug the Ethernet cable into the Ethernet socket on the back of the terminal 7 Insert the terminal into the flush mounted housing and push the terminal down until it snaps into place Installation 7 ...

Страница 8: ...w the display clockwise using the Allen key 9 Only Surface mounted Using the Allen key tighten the screw below the terminal clockwise If correctly installed the terminal must not be able to be moved 3 Configuration The manual for configuring and operating the XT door terminals can be found on the Adatis website under Products XT www adatis com Installation 8 ...