953.050UK User Manual
Connections
1.
Local 24Vdc power input
2.
Local audio input (mono, line level)
3.
RJ45 socket
Plug in the 8P8C connector from the 8-core control cable into the RJ45
socket on the rear of the housing (3).
If local 24Vdc power is being used
…
Connect the + wire to the
“
DC24V POWER
”
terminal Connect the - wire
to the
“
GND
”
terminal (1)
If a local audio signal is being connected
…
Connect the + wire to the
“
AUDIO INPUT
”
terminal Connect the - wire
to the
“
GND
”
terminal (1)
Operation
To operate the TR86, touch or tap buttons as detailed below.
4.
CH
and
step through audio sources (Line 1-4) for the zone
5.
BUSY indicator is lit during paging or emergency alerts
6.
+ and - increase or decrease output volume in steps
7.
Audio source indicators light to show which source is selected
8.
LOCAL
–
touch to switch to local audio input (if connected)
9.
MUTE
–
touch to mute or un-mute all output for the zone.
Backlights for LOCAL and MUTE buttons will be lit when active.
Specifications
Power supply
24Vdc (from RZ45 or external power adaptor)
Connection
8P8C (RJ45)
Terminals
Local +24V, Ground, Local line input
Controls
Sources 1-4 (USB), Local, Mute, Level +/-
Mounting depth
38mm
Dimensions
86 x 86 x 38mm
Weight
128g
Disposal:
The “Crossed Wheelie Bin” symbol on the product means that the product is classed as Electrical or
Electronic equipment and should not be disposed with other household or commercial waste at the end of its useful life.
The goods must be disposed of according to your local council guidelines.
Errors and omissions excepted.
Copyright© 2017. AVSL Group Ltd.