SANbloc S50 SAS JBOD Quick Install Guide
• Liquid has penetrated the server.
• The server has been exposed to moisture.
• The server continues to operate in an unexpected manner even after
solutions suggested in the
Administration Guide
have been followed.
Installation Cautions and Notes
Caution
To prevent personal injury and equipment damage, have
someone assist you during installation. Ensure the mounting hardware
and tools are easily accessible. If necessary, reduce the weight of the
storage subsystem by removing the drive carriers and APC modules.
Note
Remove all of the components from the packaging and place them
on an antistatic surface until you are ready to use them. If you are using
new disk drives, allow them to acclimate to room temperature before you
install them in the enclosure and power on the system. Before beginning
the installation, inspect the components for shipping damage.
Note
Ensure that your equipment rack is placed in a dust-free, well
ventilated area close to a UPS. Leave enough room behind the rack for
servicing and to allow for sufficient airflow.
Note
For equipment racks with single or multiple storage subsystems
installed, the TMRA (manufacturers maximum recommended ambient
temperature) is 40 °C.
Note
Elevated Operating Ambient Temperature—When installed in a
closed or multi-unit rack assembly, the operating ambient temperature of
the rack environment may be greater than the room ambient. Therefore,
consideration should be given to installing the equipment in an
environment compatible with the manufacturer's maximum
recommended ambient (TMRA).
Note
Mechanical Loading—Prevent instability by installing heavier
items into the bottom of the equipment rack. Mounting of the equipment
in a rack should be such that a hazardous condition is not achieved due to
uneven mechanical loading.
Содержание 5325302040 - Sanbloc S50 Single Jbod 1.2TB 15K Sas
Страница 19: ......