8-2
Adaptec Storage Manager Pro User’s Guide
■
Channel Number
—
Indicates to which channel (bus) on the
controller the drive is attached.
■
SCSI ID—Identifies the drive on the SCSI channel.
■
Logical Unit Number (LUN)
—
The number assigned to a
subdevice (logical unit) of a SCSI device, which is usually zero
for a disk drive.
ATA disk drives are identified by a disk ID displayed in the
following format:
■
Channel Number—Indicates to which channel (bus) on the
controller the drive is attached.
■
Device ID—Identifies the drive on the ATA channel.
Storage Manager Pro displays the disk ID in the System Browser
window and in the Disk Properties dialog box.
Caution:
You should not remove a disk drive that is used by
an array. This may cause you to lose data. See
Replacing a
Failed Drive in an Array
on page 3-1.
Replacing Disk Drives
You can replace a failed drive in an array. The steps you need to take
to replace a drive in an array and have the best chance to retain your
data depend on the exact situation. See
Replacing a Failed Drive in an
Array
on page 3-1.
Caution:
You should not remove a disk drive that is used by
an array. This may cause you to lose data.
0:0
Channel Number
Device ID
Содержание 2110S - SCSI RAID Controller
Страница 1: ...R Adaptec Storage Manager Pro v1 11 User s Guide...
Страница 6: ......
Страница 52: ...3 9 Managing Arrays For more information about each of the properties tabs refer to the Online Help...
Страница 137: ...B 7 Choosing Your Array Type...