background image

CO9106 V1_120612

INSTALLATION & USER MANUAL

S L I M L I N E   G A S   F I R E

m o d e l   n o .   E c o 4

www.adamfires.co.uk

THIS IS NOT A DIY PRODUCT AND MUST BE 

INSTALLED BY A GAS SAFE REGISTERED INSTALLER

  

ALL INSTRUCTIONS MUST BE HANDED TO THE USER 

FOR SAFE KEEPING

Содержание Eco4

Страница 1: ...O N U S E R M A N U A L S L I M L I N E G A S F I R E m o d e l n o E c o 4 www adamfires co uk THIS IS NOT A DIY PRODUCT AND MUST BE INSTALLED BY A GAS SAFE REGISTERED INSTALLER ALL INSTRUCTIONS MUST BE HANDED TO THE USER FOR SAFE KEEPING ...

Страница 2: ...8 A Gas Safe Registered installer must be used for this purpose Read all these instructions before any installation takes place and in conjunction with the appliance on site This appliance must be installed in accordance with the rules in force and only used in a sufficiently ventilated space This appliance is factory set and tested for operation on the gas type and at the pressure stated on the a...

Страница 3: ... supplied correlate with the component checklist below If for some reason any of the listed components are missing or damaged do NOT commence with this installation in doing so will invalidate your warranty Please dispose of all the packaging materials at your local recycling centre CONTENT CHECK LIST x1 Firebox and Burner Tray x1 Decorative Trim Frame x1 Fire Fret Front x1 Rear Matrix Fuel Bed su...

Страница 4: ... C T D E T A I L S CUSTOMER HELPLINE www firedupgroup co uk Fired Up Corporation Ltd Fired Up Buildings St Thomas Road Huddersfield HD1 3LF United Kingdom C PART OF 08448 809 301 customer support firedupgroup co uk ...

Страница 5: ...ning 17 20 7 2 Fitting the Burner Tray 20 22 08 Fuel Bed Layout 22 27 09 Fitting The Decorative Frame 27 10 Spark Failure 28 11 Setting Pressure 28 29 12 Flue Spillage Monitoring System 29 13 Testing for Spillage 30 14 Briefing the Customer 31 15 Servicing 32 16 Cleaning the Coals 33 17 Troubleshooting Guide 33 35 18 User Instructions 36 41 19 List of Spares 42 48 20 Warranty Details 48 21 Warrant...

Страница 6: ...Scotland Consolidation Regulations issued by the Scottish Development Department BS 1251 BS 4543 part2 BS 5440 parts 1 2 BS 5871 part 3 BS 6461 parts 1 2 BS 6891 BS 8303 Failure to comply with these regulations could lead to prosecution and deem the warranty Invalid This appliance must be installed in accordance with the rules in force and used only in a sufficiently ventilated space Consult all i...

Страница 7: ...stible insulating surface at least 12mm thick covering the entire base area of the box The flue must have an effective height of at least three metres as measured from the hearth to the top of the flue Any flue damper plates or restrictors must be removed and no other restriction fitted to the flue Where removal is not practical the restriction must be fixed in the fully open position The flue mus...

Страница 8: ...ression 8mm Compression Overall Height 583 583 583 583 Overall Width 470 470 470 470 Overall Depth 119 139 119 139 Recess Height 548 548 548 548 Recess Width 320 320 320 320 Recess Depth 121 141 121 141 Air Vent N A N A N A N A Manual Remote Slide Manual Remote Pilot Assembly Thermocouple Oxy pilot NG Oxy pilot NG Thermocouple Oxy pilot LPG Thermocouple T100 1332 250 84009079000 84009079000 T100 1...

Страница 9: ... during commissioning is almost always a result of poor flue performance that cannot be corrected by any amount of ventilation For Republic of Ireland ventilation may be required see IS 813 ICP3 IS 327 and any other rules in force SITE REQUIREMENTS The fireplace opening should be inspected and repairs made where necessary A chair brick or fireback may be left in place providing that the dimensiona...

Страница 10: ...edge or fender 50mm high To enable the product of combustion to be cleared properly up the flue the outlet at the back of the appliance must have a 50mm minimum clearance between it and the back wall of the opening or any other obstruction The area immediately above the outlet must form a smooth path into the flue The fireplace or builders opening must be reduced to suit the appliance both side to...

Страница 11: ...owever if a hearth is not to be used so as to maintain a minimal and contemporary look the appliance must be installed so that every part of any naked flame or incandescent part of the fire bed is at least 300mm vertically above any carpet or floor covering When no hearth is to be fitted consideration must be given to fixing a tactile barrier to protect young children the elderly and the infirm A ...

Страница 12: ... be necessary for certain flue boxes Please ensure the firebox does not obscure the flue box outlet The firebox base of the flue box and hearth below may be drilled to allow plugs and screws to secure installation It is important that the sealing requirements of the appliance are met at all times and that the flue box is sealed to any back or infill panel Note The DEPTH dimension is inclusive of a...

Страница 13: ...nce with specifications laid down in the appropriate sections of these instructions Remove the appliance from its carton as described previously and stand on a dust sheet Place the coals ceramics and fixings safely to one side Remove the manual burner from the assembly by removing the two screws at the base of the burner tray and undoing the connecting nut to the isolation tap SCREWS NUT ISOLATION...

Страница 14: ...ssemble the linkage by removing the two screws shown in diagram below to the slide control then remove the burner from the assembly by removing the three screws at the base of the burner tray and undoing the connecting nut to the isolation tap on the side ...

Страница 15: ...mote controlled version of the this fire then care is needed when removing the burner not to damage the wiring system of the fire you will need to remove the control box Heat Shield and battery holder placed at the back of the fire box Carefully remove the spark generator from the box or remove the cables to the generator making a note of which cable goes where ...

Страница 16: ...wdriver and a sharp tap from a hammer and fit the rubber grommet supplied On the slide control option the position is located on the opposite side than shown Note DO NOT install or use the appliance without this seal in place Failure to fit this seal correctly will cause the flue suction to act upon the area under the burner tray resulting in poor performance and overheating of this area Heat shie...

Страница 17: ...eck the fit is good Ensure that it slides in correctly the sealing face sits flat and square to the wall or back panel and that the base is level with the hearth as no leaks are permissible here At this stage it is essential to ensure that the spigot outlet of the fire is not obstructed in any way Remove the fire box and apply the self adhesive sealing strips around the edge of the rear of the fir...

Страница 18: ...give a similar configuration as possible Thread the tensioning cable through the holes at the top of the firebox then through the two screw eyes in the top position and then through the one at the lower position back through the lower hole in the firebox as shown in the diagram Through holes at the top of the fire box Through Screw eyes Through Screw eye at the bottom and through hole near base of...

Страница 19: ...y Fixing by screw Mark and drill the fire frame or base and relevant points in the opening or on the wall wall plugs will be required Note Fibre wall plugs might be preferred rather than plastic wall plugs as the heat from the fire might affect their efficiency Whilst the opening is ready for installation of the fire the gas supply can be routed as required and connected to the isolation tap via t...

Страница 20: ...t the burner tray and ensure a suitable gas route can be achieved If the fire is the manual control system you can now place the burner tray into the firebox making sure that the side lugs locate properly on to the side of the firebox Fit the two securing screws through the front plate ensuring that the plate is in front of the front edge of the fire box Connect the gas supply and tighten the gas ...

Страница 21: ...d connected to the battery lead and the battery heat shield bent to form the cover to ensure that the battery pack does not overheat Note Fitting the batteries incorrectly could lead to damaging your control box Different types of batteries or old and new batteries are not to be mixed Only batteries of the same or equivalent type as recommended are to be used Batteries are to be inserted with the ...

Страница 22: ...d with alternative Fire Fret Front FUEL BED LAYOUT Do not place the remote sensor any where above this point Remote sensor Place the ceramic rear matrix onto the burner ensuring that the rear matrix is sitting behind the two fixed brackets the back of the matrix rests against the back panel fitted at the rear of the box Place battery holder and cover here ...

Страница 23: ...orrectly which may cause damage to the fire and malfunction BURNER FRONT MATRIX PILOT ASSEMBLY Note Please ensure that there is a gap between the back of the front matrix and the pilot assembly where applicable This is to ensure correct operating of the pilot and O D S system This must not touch the assembly as this will cause the fire to operate incorrectly and cause damage to the fire Place fron...

Страница 24: ...no flames play onto the firebox sides as this will reduce the heat output Place the front row of 5 coals pebbles between the front coal support and the rear matrix as shown Now Place the second row as shown below coals may be rotated slightly within their positions to give a good visual effect The coals pebbles MUST be placed sitting on top of the front ceramic resting between the pillars of the f...

Страница 25: ...TRADITIONAL RANDIOM COAL BED OPTION First identify the parts please see below Random coal front matrix 5x Coal A 4x Coal B Place the Random Coal Front matrix in place ensuring that it does not touch the pilot assembly behind ...

Страница 26: ...t matrix and the rear matrix as shown Do not block the area between the coal supports Place the three coals A as shown again ensuring that the area between the coal supports is clear Place the two coals B at each end of the rear matrix behind the two coals as shown ...

Страница 27: ...lowed by the top bar which should overlap the sides IMPORTANT NOTE Due to the possibility of sharp edges care should be taken when handling the three piece frame components the use of protective gloves is recommended Place the fire front fret into position in front of the fire and slide the ashpan door into place The fire front fret shown in these instructions may differ from the one supplied with...

Страница 28: ... a taper Note Please ensure that the electrode spark igniters gap on the manual version has not been misaligned during the handling of the burner In this installation the gap should be 5mm from the burner SETTING PRESSURE Remove the pressure test point sealing screw from the isolation elbow and attach a suitable pressure gauge Check that the standing inlet gas pressure is at 20 mbar Light the pilo...

Страница 29: ... gas pressure reaching the fire must also be checked again recall your installer to check and rectify any problem The thermocouple connection into the back of the gas control valve may also have worked loose during installation simply get the installer to tighten If pilot disturbance is not the cause then the ODS safety system may be in operation Switch the appliance OFF check the flue and carry o...

Страница 30: ...nto the room indicates that spillage is occurring If the initial spillage test fails run the fire for a further 10 minutes and repeat the test Please Note If using the Super Convector firebox and the spillage test fails please remove the spigot restrictor making sure to replace the screws back in to their positions and re test When the test has been completed sucessfully repeat with any extractor ...

Страница 31: ...ng care not to use excessive pressure Scratched and other superficial damage to the matt black paintwork of the appliance can be covered with matching heatproof spray Use only the manufacturers recommended spray paint Paint only when the fire is OFF and cold Always mask off the surrounding area to prevent contamination with overspray Ventilate the room during the use of the spray DO NOT attempt to...

Страница 32: ...tensioner cables from the rear of the firebox remove the securing nipples and tensioner adjusters The firebox is now released from the opening and can be slid outward onto the hearth 8 Check the fireplace opening for rubble accumulation and remove if debris is excessive initiate remedial work on the flue 9 Check the flue with a smoke pellet for correct operation 10 Refit convector box using new se...

Страница 33: ...not fully purged Re purge supply or wait longer Spark earthing to metal work Reset gap correctly Blocked pilot Clean out internally Pilot lights but then goes out before main burner lights Severe restriction in gas supply Clear obstruction Faulty thermocouple Replace pilot unit Hold control knob in for longer Run through lighting system on the remote control several times allowing the valve to res...

Страница 34: ...ase of firebox Rectify Firebox grommet seal missing rectify Remote control Remote Control Diagnostic Beeps Do not mix battery types 3 beeps Replace handset or dummy switch 4 beeps Replace Gas Valve 5 beeps Replace EDB control box 6 beeps Battery below required power Replace all batteries in the appliance 7 beeps Battery below required power Replace all batteries in the appliance Do Not use ZINC ba...

Страница 35: ...heck and rectify 3 Faulty EDB Replace if necessary No Spark at Pilot Tip 1 Electrode Broken Check and replace if required 2 Electrode lead damaged or disconnected Check and replace if necessary 3 Incorrect spark gap Check gap is between 2 5mm to 4mm 4 Spark short circuits to appliance metalwork Ensure lead is correctly routed NOTE it is normal for some sparks to discharge within the EDB control bo...

Страница 36: ...appliance become naturally hot during use It is recommended that a suitable fire guard conforming to BS 8423 is used especially where young children the elderly or infirm are concerned Combustible items such as flooring and furniture and soft wall coverings such as blown vinyl or embossed paper may discolour if fitted too close to the fire See relevant section for further details on clearances to ...

Страница 37: ...ff the gas supply if for any reason the pilot is extinguished This device incorporates a fixed probe which senses heat from the pilot burner flame if the probe is cooled the device will prevent any gas flow If for any reason the flames go out or if the fire has been turned off for any reason always WAIT FOR 3 MINUTES before attempting to re light The pilot is visible through the Fuel bed at the fr...

Страница 38: ...ion and release OPERATING THE APPLIANCE Slide control For your safety the fire is fitted with a Flame Supervision Device FSD which will shut off the Gas supply if for any reason the pilot is extinguished This device incorporates a fixed probe which senses heat from the pilot burner flame if the probe is cooled the device will prevent any gas flow If for any reason the flames go out or if the fire ...

Страница 39: ...ld down for approximately 15 seconds 2 Release the pressure and the pilot light should now be established if this fails repeat step 1 and hold down up to 20 seconds 3 Slide the control upwards to increase the flame size to the desired effect 4 To switch the fire off simply slide the control upwards past the positive stop and hold for 2 seconds ...

Страница 40: ...h to the cable on the fire using the press connection Cover with the heat shield as described on page 21 To light the fire point the handset to the sensor on the front your fire Press and hold the two buttons together on the left hand side of the handset The fire will give out a beep sound and you can release the buttons After a few seconds you will hear the spark clicking spark to the pilot light...

Страница 41: ...of the flue This should be repaired by a competent person and the fire serviced before further use FIRE FRONT FRET Any dust accumulating in the fire front may be removed using a vacuum cleaner or dry cloth Heavy stains may be removed by using a damp cloth and mild household detergent Metal parts of the fire front may be cleaned using a suitable metal cleaner Replace the front centrally against the...

Страница 42: ...4 2 S E C T I O N 1 9 LIST OF SPARES Eco4 Manual Control ...

Страница 43: ...4 3 S E C T I O N 1 9 Eco4 Slide Control ...

Страница 44: ...4 4 S E C T I O N 1 9 Eco4 Remote Control 1C 2C 4C 5C 3C 6C ...

Страница 45: ...4 5 S E C T I O N 1 9 Eco4 Ceramics ...

Страница 46: ...4 2 4 6 S E C T I O N 1 9 Eco4 Ceramics A22 A23 ...

Страница 47: ...RNER NATURAL GAS FOR REMOTE CONTROL BURNER LPG GAS FOR REMOTE CONTROL PRT PRT PRT PRT PRT PRT PRT PRT PRT PRT PRT PRT PRT PRT PRT PRT PRT PRT PRT PRT PRT PRT PRT PRT PRT PRT PRT PRT PRT PRT PRT PRT PRT PRT PRT PRT PRT PRT PRT PRT PRT CER CER CER CER CER CER CER CER CER CER VAL VAL VAL FIX DOC VAL VAL VAL VAL VAL VAL VAL E4 E4 VAL E4 VAL VAL VAL VAL VAL VAL VAL VAL VAL VAL VAL VAL VAL VAL VAL MX MX...

Страница 48: ...AL VAL ECO VAL VAL VAL VAL VAL VAL VAL VAL VAL VAL VAL VAL VAL IJ IJ 4 SL TU TU PI TH TU IJ BR SL SG IS SL SL E4 E4 N UN PI IN RO RO IN 2 E4 UN UN UN UN UN A LP SL MC SL SL PL CT SL UN NG NG NG 0 0 0 MUL MUL SI SI SI SIT SIT SI MU AE SI TC BC PL HS NGR LPR 1 4 4 1 2 2 NGR 1 1 1 2 1 1 CODE 17C 18C 1D 2D 3D 4D 5D 6D 7D 8D 9D 10D 11D 12D 13D 14D CONTINUED PART NUMBER E O 08448 809 301 customer suppor...

Страница 49: ... the user instruction book 6 The installation must be in accordance with the installation instructions and comply with all current legislation and building regulations The fire controls are getting too hot Excessive sooting is forming on the fuel bed Poor flame picture Remote controls are not working These symptoms tend to be chimney flue or installation related and as such mostly are not covered ...

Страница 50: ...me on its behalf any other liabilities with respect to the sale of the appliance 14 The guarantee does not apply to other non Adam products such as prefabricated flue boxes and flues 15 The company will not be responsible for a Inadequate or inappropriate flueing chimneys etc b down drafts or spillage caused by environmental conditions such as nearby trees buildings rooftops hills or mountains c i...

Страница 51: ...fect by a Adam engineer or an appointed Adam engineer provided that such parts have been subject to normal conditions of use 28 Any installation labour transportation or any other related expenses arising from defective parts repair or otherwise of the same are not covered by this warranty nor shall Adam Fires assume responsibility for any incidental indirect or consequential damages except as pro...

Страница 52: ... NEEDS TO COMPLETE THIS FORM NAME ADDRESS TEL NUMBER THE WORKING PRESSURE OF THE FIRE IS on high setting THE STANDING PRESSURE OF THE FIRE IS GAS RATE FLUE SPILLAGE TEST FLUE FLOW TEST DOES VENTILATION MEET APPLIANCE REQUIREMENTS PLEASE KEEP YOUR RECEIPT AND CP1 CERTIFICATE IN A SAFE PLACE AS THEY WILL BE REQUIRED GAS SAFE REG NUMBER PASS mbar mbar PASS FAIL FAIL YES SIGNED BY INSTALLER DATE NO NA...