© Adam Equipment Company 2007
13
The display will tell you to add weight to the scale: “
LoAd
” “
04
” “
kiloS
”
Add the weight shown, wait for stability then press the
[Tare]
key.
The display will show “
SPAn
” “
PASS
” if the calibration is OK. Or it will show “
SPAn
” “
FAIL
” if
calibration could not be completed correctly.
The display will then show “
JP
” “
On
” indicating the jumper is still in place. Remove the
weight. Switch off the scale and switch it on again to continue with the other Service
parameters.
8.2.2
F2
-RESOLUTION
NOTE:
This value can not be changed for the CBC-M scales.
8.2.3
F3
– CAPACITY
To enter this parameter, press the
[Tare]
key when “
F3
” is shown.
The display will show the current capacity.
Press the
[U.Wt./Units]
key to change the value.
Press
[Tare]
to accept the displayed value.
NOTE:
The scale must be originally built for the capacity selected. The 3kg unit uses the
5kg load cells, 6 kg unit uses 10kg load cells, the 15 kg unit uses 20 kg load cells and the
30 kg unit uses 35 kg load cells.
Press
[Zero]
to return to weighing.